8
-
Fine Screen Assembly Removal & Installation (Figure 6 and 7)
1. Close the inlet and the outlet line valves.
2. Set the main switch at the control panel to "0" position.
3. Verify that filter is drained prior to service.
4. Remove the cover with the motor assembly.
5. Pull the screen assembly with the brushes out of the filter housing assembly
6. Than remove the brush assembly.
7. Remove the seals from the old fine screen assembly.
8. Lubricate upper and lower seals with
silicon
grease
.
9. Slide the brush assembly into the screen and only then slide the screen assembly
with the brush assembly into the filter housing assembly.
10. Verify that the straight side of the body seal fits into the groove located in the
cover.
11. Put the cover into its place on the filter. (Take care that the motor’s axis
housing is
slide on the brush axis) & install nuts and washers
12. Set the main switch at the control panel to "1" position.
13. Open the inlet and outlet line valves.
14. Perform a flushing cycle by pressing the MANUAL FLUSH switch at the control
panel.
15. Verify that the flushing valves close after 10 flushing cycle and FLUSHING lamp at
the control panel extinguishes and Check for leaks.
WARNING
Take precautions while operating the filter because the filter might enter a flushing mode
automatically, without prior warning.
Содержание Tekleen CSB
Страница 7: ... 5 Pressure Loss At 200 Micron ...
Страница 11: ... 9 Figure 4 Figure 5 ...
Страница 12: ... 10 Figure 6 Brush Removal Installation Figure 7 Fine Screen Assembly Removal Installation ...
Страница 14: ... 12 ...
Страница 20: ... 18 ...
Страница 21: ... 19 ...