AUTOMATED EQUIPMENT RAM 16-F Скачать руководство пользователя страница 24

RAM™ 16-F & 16-Fp Space Saver Frozen Fry Dispensers 

Copyright © 2019      Automated Equipment LLC    All rights reserved.    Published 8/19

 

22

Specification

Electrical Requirements: 

Domestic: 

  120 VAC., 60 HZ, 8 A, 1

Φ

 

International: 

 240 

VAC., 

50 HZ,

 4.6 A, 1

Φ

 

 240 

VAC., 

60 HZ

, 4.6 A, 1

Φ

 

Internat Circuit Breaker:

  

15 A 

Dimensions: 

  16" wide, 27.64" deep, 68.69" high 

(407mm x 702mm x 1745mm) 

Minimum Operating Clearance Shall be: 

  1” (2.6 cm) clearance on each side 

  2” (5 cm) clearance at the back 

  Open to ceiling, minimum 24” (61 cm) 

Weight:  

  253 lbs. (115 kg) 

Hopper Capacity: 

  36 lbs. (16.3 kg), weight may vary with product. 

Operating Temperature: 

  4

F to 0

F (-15

C to -18

C) (Recommended Ambient Operating Temperature of 75

F (24

C)) 

  Climate Class= N 

Maximum Operating Altitude & Safe Tilt: 

 Maximum 

Altitude: 

7000 

ft

 

(2,134 meters), Maximum Tilt = 10 degrees 

Insulation Blowing Gas: 

  H

2

Noise Emissions: 

 < 70 dB (A) 

Refrigeration Specifications:

 

 Domestic: 

 

Model 16-F Refrigerant: 

R404A

: 13 oz. (368g),  

      International:  

Model 16-F Refrigerant: 

R404A:

 13 oz. (368g) 

Model 16-Fp Refrigerant: 

R290

: 5 oz. (142g) 

  Suction Pressure: 3-7 psi at -3° to 3°F (21 kPa to 48 kPa at -19° to -16°C) 

  Operating Temperature: 4

F to 0

F (-15

C to -18

C) 

  Factory Temperature Set Point: 0°F (-18°C) 

  Factory Differential Set Point: 4°F (3°C)  

  High Pressure Switch: opens at 425 psi (2890 kPa), resets at 325 psi (2210 kPa) 

        

 

Содержание RAM 16-F

Страница 1: ...om Business Hours Monday Friday 8 00 AM to 5 00 PM CST excluding holidays After hours your call will be handled by a voice mail paging service The on call technician will be paged and will return your call Table of Contents Introduction 1 Unpacking Installation 1 Intended Use 1 Equipment Safety 2 Dispenser Assembly 5 Operator Panel and Controls 6 Start up and Operation 7 Daily Closing Disassembly ...

Страница 2: ...OR DIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FURNISHING PERFORMANCE OR USE OF THIS MATERIAL This manual is copyrighted with all rights reserved Under the copyright laws this manual may not be copied in whole or part without the written consent of Automated Equipment LLC Product names mentioned herein are for identification purposes only and may be trademarks and or regi...

Страница 3: ...nser is designed for installation and use indoors in a restaurant environment protected from weather excessive heat excessive humidity and salt air HAZARD COMMUNICATION STANDARD Hazard Communication Standard HCS Procedures in this manual may include the use of chemical products These chemical products will be highlighted with boldface letters followed by the abbreviation HCS in the text of the pro...

Страница 4: ...hould service the electrical system DO NOT SPRAY THE DISPENSER WITH LIQUID OR SOLVENTS It is not sealed against jetting fluids and contamination may get into sensitive components Spraying the dispenser may void the warranty Use caution when handling heavy parts such as back and top panels Always reinstall service panels when maintenance is complete Do NOT drill or otherwise puncture cabinet walls ...

Страница 5: ... and near Power Cord inlet CAUTION RISK OF ELECTRIC SHOCK INDICATES HAZARDOUS VOLTAGE WITHIN DISCONNECT POWER BEFORE SERVICING UNIT Label is located on the rear access panel and applies to both the drum motor and outlet door assemblies within the enclosure CAUTION MOVING PARTS DO NOT OPERATE WITH PANEL REMOVED Label is located on the front and applies to the outlet door assembly CAUTION MOVING PAR...

Страница 6: ...ION RISK OF FIRE KEEP OPEN FLAME FROM EXPOSED INSULATION WHEN SERVICING REFRIGERENT IS FLAMMABLE MODEL 16 FP ONLY R290 REFRIGERANT US and International Warning Keep ventilation openings in the appliance enclosure particularly in the back bottom panel clear of obstruction Caution The 16 Fp utilizes R290 propane as a refrigerant Release of refrigerant into the atmosphere is strictly prohibited Cauti...

Страница 7: ...rd the back wall engaging the Alignment Arrow See page 10 if the alignment Arrow is in the closed position With your hands removed turn the dispenser on the Outlet Door will retract into the closed position Install the Drum into the Hopper making sure the square opening in the drum is pointed toward the rear of the Hopper Install the Fry Diverter in the Hopper by sliding the Fry Diverter tabs into...

Страница 8: ...ture and displays the current cabinet temperature The dispenser s controller can also detect an abnormal refrigeration condition When an error condition is detected the display will state the error that has occurred The Dispenser Button operates both the Dispensing Drum and the Outlet Door When the Dispense Button is pressed the Outlet Door moves to the dispensing open position and the drum begins...

Страница 9: ...g technique for loading frozen fries into the Hopper For each bag or box of fries 1 Remove the bag of fries from the case Be careful not to crush the fries 2 Open the top of the bag or box completely A partially open bag may retain fries 3 Hold the opened end of the bag closed with your hand and lay it in the Hopper with the opening toward the side opposite of the Diverter 4 Release the opened end...

Страница 10: ... and Drip Tray Spacer 5 Open the Cabinet Door and allow 1 hour to defrost Caution Never use a sharp object to remove frost build up Never drill or otherwise puncture cabinet walls or top Take the removable components from the Dispenser to the washing area Wash them with a hot solution of detergent and water Rinse each component with clear water and sanitize wash rinse sanitize HCS Allow components...

Страница 11: ...he set point can be adjusted by using the up and down arrow keys The new set point is stored by pressing the SET key again Locking the Controller The controller keys may be locked by pressing both the up and down keys for 3 seconds The display will flash PoF The keys are now locked and cannot be used to change any parameter the set point is still visible by pressing the set key To unlock the keys ...

Страница 12: ...t below provides an explanation of each error message and what action may be needed to correct the problem Alarm Message Cause Corrective Action P1 flashing Thermostat probe failure Power off wait one minute power on Check probe connections on back of controller Pins 11 and 12 See schematic at end of manual Replace probe HA alternating with freezer temperature Maximum temperature alarm Power off w...

Страница 13: ...abled LED is off and the compressor is running suspect a stuck refrigeration relay or controller fault If the Compressor Enabled LED is on and the temperature reading is below the set point suspect the controller Not dispensing fries Hopper is empty Verify product is in the hopper Fries are bridged in the hopper Re distribute fries to break up the bridge Drum not turning Verify Dispensing Drum soc...

Страница 14: ...296444 293706 293855 Door Gasket Hinge Door Screw Truss Head Phillips 3 8 16x 6 1 296484 Support Cabinet Right 7 1 296483 Support Cabinet Left 8 1 1 1 2 296512 296505 296506 296508 Kit Basket Rack Side Mount Basket Rack Side Mount Drip Tray Support Pins Basket Rack 9 1 310125 296671 Drip Tray Drip Tray Spacer 10 1 1 296480 295845 Access Plate Condenser Filter Filter Condenser 11 1 2 296581 294092 ...

Страница 15: ...cription 1 1 296650 Outlet Door 2 1 310125 Drip Tray 3 1 296671 Drip Tray Divider Interior Parts Front View Item Qty Part Description 1 1 291411 Probe Temperature 2 1 291284 P Clip 3 1 295234 Spacer 4 1 292058 Grommet 5 1 1 1 296525 296178 202366 Hopper Diverter Drum 6 4 295699 293720 Hopper Support Screw FH Slotted 10 32x1 Not shown 1 293966 Rack Hashbrown Optional 2 1 3 4 6 5 2 3 1 ...

Страница 16: ...d 4 relay control boards 9 1 See page 18 Drum Motor Assembly 10 1 See page 18 Outlet Door Assembly 11 1 295681 Kit Bumper Wall set of 2 12 1 294339 294723 296329 Compressor Dom 120V 60HZ 1 2hp Compressor Intl 240V 50HZ 1 2hp Compressor Intl 240V 60HZ 1 2hp 13 1 292501 Filter Drier 14 4 16 16 16 293434 200774 290012 216159 Caster Screw Hex Head 5 16 18x3 4 Nut Hex 5 16 18 Washer 5 16 Not shown 1 29...

Страница 17: ...Button 2 1 310082 310083 Temperature Controller Domestic F Temperature Controller International C 3 1 292246 On Off switch Not Shown 1 298533 Door Heater Wire Outlet Door Assembly Item Qty Part Description Item Qty Part Description 1 1 290133 Motor Gear 24 VDC 4 3 203249 Switch Micro 2 1 296496 Bracket Motor Mount Not shown 1 296493 Shaft Door Drive 3 1 296495 Plate Switch Mount Not shown 1 296500...

Страница 18: ...ublished 8 19 16 Parts identification Cont Drum Motor Assembly Item Qty Part Description Item Qty Part Description 1 1 292546 Motor Gear Brushless 24 VDC 4 4 213136 Cap Screw Socket HD 10 32x1 2 1 202797 Bracket Mount Drum motor 5 1 293318 Drum Shaft 3 4 213140 Washer Lock 10 6 2 290653 Set Screw 3 8 24 x 3 8 ...

Страница 19: ...operation Defrost Because the dispenser employs a cold wall design it will be necessary to manually defrost the cabinet daily First remove the product Turn the On Off Switch Remove Baskets Hopper Outlet Door Drip Tray and Drip Tray Divider Open the Cabinet Door and allow 1 hour to defrost Caution Never use a sharp object to remove frost build up Never drill or otherwise puncture cabinet walls or t...

Страница 20: ...Overload Switch 1 2hp Int 240V 50HZ 404A Overload Switch 1 2hp Int 240V 60HZ 404A Overload Switch Model 16 Fp R290 only 1 2hp Int 240V 50HZ Start Relay 1 2hp Dom 120V 404A Start Relay 1 2hp Int 240V 50HZ 404A Start Relay 1 2hp Int 240V 60HZ 404A Start Relay Model 16 Fp R290 only 1 2hp Int 240V 50HZ Start Capacitor 1 2hp Dom 120V 404A Start Capacitor 1 2hp Int 240V 50HZ 404A Start Capacitor 1 2hp I...

Страница 21: ... Dispensers Copyright 2019 Automated Equipment LLC All rights reserved Published 8 19 19 Refrigeration Circuit 404A Refrigerant Dom intl 86 218cm Intl 50HZ only 105 267cm R404A Refrigerant 13 0 oz 368g dom 13 0 oz 368g Intl RAM Space Saver ...

Страница 22: ...ozen Fry Dispensers Copyright 2019 Automated Equipment LLC All rights reserved Published 8 19 20 Refrigeration Circuit R290 Refrigerant Intl 50HZ only 122 310cm R290 Refrigerant 5 0 oz 141 7g dom 5 0 oz 141 7g Intl RAM Space Saver ...

Страница 23: ...RAM 16 F 16 Fp Space Saver Frozen Fry Dispensers Copyright 2019 Automated Equipment LLC All rights reserved Published 8 19 21 Electrical Diagram ...

Страница 24: ... weight may vary with product Operating Temperature 4 F to 0 F 15 C to 18 C Recommended Ambient Operating Temperature of 75 F 24 C Climate Class N Maximum Operating Altitude Safe Tilt Maximum Altitude 7000 ft 2 134 meters Maximum Tilt 10 degrees Insulation Blowing Gas H2O Noise Emissions 70 dB A Refrigeration Specifications Domestic Model 16 F Refrigerant R404A 13 oz 368g International Model 16 F ...

Страница 25: ... and related systems Service fees are in accordance with industry standards Replacement parts are available through local Service Support Center Parts Distributors or direct from us by calling 1 800 248 2724 U S Canada or 651 385 2273 in the event a local distributor is not available Our Technical Support Hot Line is available for telephone assistance providing product technical support parts and ...

Страница 26: ...d out by qualified personnel in accordance with the manufacturer s instructions local safety regulations must be observed Dispose of the equipment in accordance with local regulations It is important to observe the regulations and laws for disposing of environmentally unfriendly materials You must understand and follow the proper procedures on the disposal of materials such as refrigerants insulat...

Страница 27: ...RAM 16 F 16 Fp Space Saver Frozen Fry Dispensers Copyright 2019 Automated Equipment LLC All rights reserved Published 8 19 25 Notes ...

Отзывы: