The
blue
square
which
can
be
seen
in
the
map
changes
its
position
within
the
horizontal
axis
depending
on
the
actual
petrol
injection
time
value
and
within
the
vertical
axis
depending
on
the
actual
rpm
value.
2.16.
Gas
temperature
calibration
map
The
Gas
calibration
map
opens
in
the
Map
window
after
selecting
the
“Temperature
calibration”
tab.
Fig.
20
Gas
temperature
calibration
map
view.
The
controller
has
the
gas
temperature
multiplier
calibration
value
permanently
set.
The
gas
temperature
calibration
map
enables
percentage
adjustments
of
this
calibration
value.
Editing
the
gas
calibration
map
is
analogous
to
the
same
function
performed
in
the
case
of
the
multiplier
map.
2.17.
Controller
update
To
update
the
controller,
connect
it
to
the
diagnostic
software
and
turn
the
engine
off.
Select
“Controller
update”
from
the
main
menu
and
select
(STAG
‐
200,
STAG
‐
4,
STAG
‐
300
Plus,
STAG
‐
300
Premium),
depending
on
the
connected
controller
type.
The
“Controller
update”
window
will
pop
up.
The
“Controller
Parameters”
window
shows
the
information
on
current
controller
firmware
version.
The
“Available
actualizations”
window
includes
a
list
of
updates
available
for
the
connected
controller.
Loading
an
update
not
included
in
the
program
directory
requires
clicking
“Load
update”
and
selecting
the
update
file.
Loaded
update
should
be
included
in
the
list
of
available
updates.
Click
“Update”
once
the
update
file
has
been
selected
from
the
list.
When
the
progress
bar
reaches
100%,
the
controller
will
disconnect
and
then
re
‐
connect.
The
new
version
number
should
appear
at
the
bottom
of
the
screen
and
should
reflect
the
version
number
of
the
update
file.
Should
the
update
go
wrong
the
update
window
will
be
opened
automatically
upon
connecting
with
the
controller.
Perform
the
update
procedure
again.