![AutoAnchor AA702 Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/autoanchor/aa702/aa702_owners-manual_3020971027.webp)
26
A system with one base station (6 outputs) can operate:
•
1 windlass plus a thruster and 2 optional functions eg a deck wash, deck light,
anchor stow or electric cleat.
•
1 dual speed windlass, plus a thruster with power enable.
•
or 1 windlass plus 4 auxiliary functions.
•
or 1 windlass plus 2 thrusters.
•
or 4 auxiliary outputs.
A system with two base stations (12 outputs) can operate:
•
1 windlass plus 2 thrusters and up to 4 auxiliary or optional functions.
•
2 windlasses plus 2 thrusters plus up to 4 auxiliary or optional functions.
•
unused outputs can be used for auxiliary functions (maximum 4).
Example system setups are overleaf.
Follow the screen prompts to select the functions for each base station.
Note:
When selecting the base station this message may appear for a
few seconds. If it stays for longer than 30 seconds the base station may
not be powered up or it may be too far away.
3.6.1 BASE STATION OUTPUTS
AA702
Terminal
Default Function
Assignment
Alternative Function Assignment
BATT (-)
Ground
BATT
(+)
Positive
OUT 1
(+)
1
Windlass
Down
Power Enable when
dual thrusters selected
OUT 2
(+)
1
Windlass
Up
OUT 3
(+)
2
Thruster A (Bow)
Port
Windlass
Option A
OUT 4
(+)
2
Thruster A (Bow)
Starboard
Windlass
Option B
OUT 5
White
(+)
2
Thruster B (Stern)
Port
Power Enable
3
Rope/Chain
Motor Load Wires
OUT 6
Brown
(+)
2
Thruster B (Stern)
Starboard
Dual Speed
3
Rope/Chain
Motor Load Wires
Notes:
Unused outputs are automatically assigned as auxiliary outputs. See Pages 25 and 29 for more
details. All outputs are active high (+).
1
Only one windlass can be connected to a base station. 2 windlasses require 2 base stations. The
windlass outputs OUT1 and OUT2 are fixed, however, the control buttons for up and down can be
swapped in the set up menu as can the location of the windlass (bow or stern).
2
Stern and bow thruster output locations stated are the default locations. These can be swapped in
the set up menu. The port and starboard directions for each output cannot be changed.
3
Only required for rope/chain counting
OUT 5 = White Motor Load Wire
OUT 6 = Brown Motor Load Wire
Содержание AA702
Страница 1: ......