12
13
AUTOMATED CONDITIONS
If the battery needs charging the XTC-160 will automatically charge the battery and then
run a Load Test. The LED indicators will show the status during a fully automated Test and
Charge sequence. This makes it possible to view the status and final results at a distance.
Red "TESTING" light indicates battery
is being tested.
Red "CHARGING" light indicates
battery is being charged. .
Green "GOOD" light indicates battery is good.
Green "GOOD" with Red
"CHARGING" light indicates battery is
being charged. .
Green "GOOD" with Green
"CHARGED" light indicates battery is
good and has been charged.
Yellow See Display indicates that some
condition occurred that did not let the
battery charge or that the battery is Near
End of Life. See the display for details.
Red "BAD" indicates the battery is too
bad to charge or is considered bad
after a charge is attempted.
CHARGE and TEST SEQUENCE cont
LCD TEST RESULTS:
Include
"GOOD BATTERY" "GOOD, "NEAR
END OF LIFE" and "BAD BATTERY".
#290 12V BATTERY
GOOD BATTERY
MEAS. CCA 975
'Y' PRINT – MORE
Press 'Y' to print results on store printer.
Press - to see "WHAT NEXT" screen.
Press 'N' to go back to menu
.
.
CHARGING
TIME LEFT: 10 MIN
CHRG CURR: 50A
'N' TO STOP
If the battery temperature goes over 140°F charging will stop.
If no temperature probe is connected use the +(Up) and -(Down) keys to enter the current battery temp.
The (Up) & (Down) keys increment & decrement in units of 10. Press ‘Y’ to begin. If temperature probe is
connected, point the temperature probe at the battery and press the button on the temperature probe to
input battery temperature.
CHARGE ONLY SEQUENCE
From the menu select CHARGE ONLY using the +/- keys.
Then press ‘Y’ Enter to enter.
Summary Screen
>STARTING STANDRD
BATTERY TEMP 70°
RATED CCA = 600
‘N’ OR ‘Y’
Confirm that the inputs are correct.
Press ‘Y’ if they are correct. The
charge will start. Press ‘N’ to re-enter
temp, battery rating and battery type.
CHOOSE BATT TYPE
STARTING STANDRD
USE +/-,
‘Y’ TO CONTINUE
BATTERY TYPE OPTIONS:
STARTING STANDRD
STARTING AGM
DEEP CYCLE AGM
DEEP CYCLE STANDRD
Press the (+Up) or (-Down) key to
cycle through the battery types. Press
'Y' when it matches the type of battery
you are testing.
The rating displayed will be either the default rating or the last entered rating will be displayed (this setting
can be changed at setup). Adjust the rating using the +/- keys.
ENTER RATED CCA
1350
USE +/-.
‘Y’ TO BEGIN.
>ENTER BATTERY
TEMP. 70F
USE +/-
‘Y’ TO BEGIN
The unit will go back to main
menu.
THE BATTERY
NEEDS TO COOL
BEFORE CHARGING
‘Y’ TO CONTINUE
THE BATTERY
IS TOO HOT TO
CHARGE SAFELY
‘Y’ TO CONTINUE
If the battery temperature is above 120° the following message will appear
TESTING BATTERY
PLEASE WAIT...
'N' TO STOP
#290 12V BATTERY
CHARGED ONLY
12.60 CHRG 100%
'Y' TO PRINT – MORE
CHARGE & TEST
>CHARGE ONLY
TEST ONLY
REVIEW/PRINT