12

13

AUTOMATED CONDITIONS

If the battery needs charging the XTC-160 will automatically charge the battery and then 

run a Load Test. The LED indicators will show the status during a fully automated Test and 

Charge sequence. This makes it possible to view the status and final results at a distance.

  Red "TESTING" light indicates battery 

is being tested.

  Red "CHARGING" light indicates 

battery is being charged. .

  Green "GOOD" light indicates battery is good. 

  Green "GOOD" with Red 

"CHARGING" light indicates battery is 

being charged. .

  Green "GOOD" with Green 

"CHARGED" light indicates battery is 

good and has been charged.

  Yellow See Display indicates that some 

condition occurred that did not let the 

battery charge or that the battery is Near 

End of Life. See the display for details.

  Red "BAD" indicates the battery is too 

bad to charge or is considered bad 

after a charge is attempted.

CHARGE and TEST SEQUENCE cont

LCD TEST RESULTS:

 Include 

"GOOD BATTERY" "GOOD, "NEAR 

END OF LIFE" and "BAD BATTERY".

#290 12V BATTERY 

GOOD BATTERY 

MEAS. CCA 975 

'Y' PRINT – MORE

Press 'Y' to print results on store printer.

Press - to see "WHAT NEXT" screen.

Press 'N' to go back to menu

.

.

CHARGING 
TIME LEFT: 10 MIN 
CHRG CURR: 50A 
'N' TO STOP

If the battery temperature goes over 140°F charging will stop.

If no temperature probe is connected use the +(Up) and -(Down) keys to enter the current battery temp. 

The (Up) & (Down) keys increment & decrement in units of 10. Press ‘Y’ to begin. If temperature probe is 

connected, point the temperature probe at the battery and press the button on the temperature probe to 

input battery temperature.

CHARGE ONLY SEQUENCE 

From the menu select CHARGE ONLY using the +/- keys.

Then press ‘Y’ Enter to enter.

Summary Screen

>STARTING STANDRD

 BATTERY TEMP 70° 

 RATED CCA = 600 

 ‘N’ OR ‘Y’

Confirm that the inputs are correct. 

Press ‘Y’ if they are correct. The 

charge will start. Press ‘N’ to re-enter 

temp, battery rating and battery type.

CHOOSE BATT TYPE 

STARTING STANDRD 

USE +/-, 

‘Y’ TO CONTINUE

BATTERY TYPE OPTIONS: 

STARTING STANDRD 

STARTING AGM 

DEEP CYCLE AGM 

DEEP CYCLE STANDRD

Press the (+Up) or (-Down) key to 

cycle through the battery types. Press 

'Y' when it matches the type of battery 

you are testing.

The rating displayed will be either the default rating or the last entered rating will be displayed (this setting 

can be changed at setup). Adjust the rating using the +/- keys.

ENTER RATED CCA

1350 

USE +/-.

‘Y’ TO BEGIN.

>ENTER BATTERY 

 TEMP. 70F 

 USE +/- 

 ‘Y’ TO BEGIN

The unit will go back to main 

menu.

THE BATTERY 

NEEDS TO COOL

BEFORE CHARGING 

‘Y’ TO CONTINUE

THE BATTERY 

IS TOO HOT TO 

CHARGE SAFELY 

‘Y’ TO CONTINUE

If the battery temperature is above 120° the following message will appear

TESTING BATTERY 
PLEASE WAIT...
 
'N' TO STOP

#290 12V BATTERY
CHARGED ONLY 
12.60 CHRG 100% 
'Y' TO PRINT – MORE

 CHARGE & TEST 

>CHARGE ONLY 

 TEST ONLY 

 REVIEW/PRINT

Содержание XTC-160

Страница 1: ...ltimate load tester and battery charger with fast and accurate automated testing and charging for the professional 2650 1742 00 10 9 13 Auto Meter Products Inc 413 West Elm Street Sycamore IL 60178 Se...

Страница 2: ...of this product Improper use accident water damage abuse unauthorized repairs or alterations voids this warranty The manufacturer disclaims any liability or consequential damages due to breach of any...

Страница 3: ...ery side terminals When testing dual post batteries always check the post to which the system is attached CARE AND MAINTENANCE CHECK OFTEN FOR LOOSE JAWS OR DAMAGED INTERNAL PLASTIC SHOULDER INSULATOR...

Страница 4: ...pection and Visual Check 6 What to Expect 7 Controls and Functions 8 Hook Up 9 Battery Charge and Test Sequence 10 12 Charge Only Sequence 13 Test Only Sequence 14 15 Test Results 16 Setup 17 18 Print...

Страница 5: ...load clamps to prevent arcing and potential explosion from battery gases Never remove load clamps while testing Keep sparks flames or cigarettes away from batteries Provide adequate ventilation to re...

Страница 6: ...e electrical system testing depends on all the components being in good operating condition In addition the battery MUST have sufficient charge for testing Carefully perform the following before attem...

Страница 7: ...Y OR N SELECT PRINTER PR 16 PRINTER USE Y TO SELECT This allows you to enter save the following company information which is included in printouts Company name address city state zip code and phone nu...

Страница 8: ...Spanish or French Language Set the LED display contrast Settings are from 1 to 10 Press y when contrast is at an acceptable level Select the rating from CCA MCA CA AH The tester charger factory defau...

Страница 9: ...t to connect the positive red clamp first Make sure the connection is certain Then connect the negative black clamp 3 If the XTC 160 displays one of the following messages check your connections Conne...

Страница 10: ...u ENTER RATED CCA 1350 USE Y TO BEGIN The rating displayed will be either the default rating or the last tested rating will be displayed this setting can be changed in setup Adjust the rating using th...

Страница 11: ...ey to cycle through the battery types Press Y when it matches the type of battery you are testing BATTERY TYPE OPTIONS STARTING STANDRD STARTING AGM DEEP CYCLE AGM DEEP CYCLE STANDRD CHOOSE BATT TYPE...

Страница 12: ...e Up and Down keys to enter the current battery temp The Up Down keys increment decrement in units of 10 Press Y to begin If temperature probe is connected point the temperature probe at the battery a...