8
17
1.
AC On/Off
Switch LCD turns
on when AC switch is on.
2
. LCD:
Displays menus
and test results
3.
KEYS
When each key is pressed a
beep sounds to assure contact
has been made
.
Y Enter
Key:
This key selects the main or next
menu. It also selects the cursor
line item and answers yes to a
test progression.
+Up
Key:
This key moves the cursor up in
order to select a menu line item.
It also increments a value.
-Down
Key:
This key moves the cursor down
USB Type A
- For data
download to flash memory and
USB printer connection.
USB Type B
USB Mini B Connection - future
expansion factory use.
CONTROLS AND FUNCTIONS
SETUP
Scroll Down to Setup, Select setup
by pressing Y'.
Select the temp in Fahrenheit or
Centigrade.
Choose whether to have the temperature
probe take the battery temperature
automatically or wait until the probe
button is pressed.
Choose between English,
Spanish or French Language.
Set the LED display
contrast. Settings are
from 1 to 10. Press 'y'
when contrast is at an
acceptable level.
Select the rating from CCA, MCA, CA,
AH.
The tester/charger factory default settings are English, F (Temp), CCA,
600 CCA, (Good or Bad only). To change the settings, setup menu's
below.
>SET TEMPERATURE
SCALE: F.
USE +/-.
‘Y’ TO SELECT
>SET LANGUAGE
ENGLISH
USE +/-.
‘Y’ TO SELECT
>DEFAULT BATTERY
RATING: CCA
USE +/-.
‘Y’ TO SELECT
>TEMP MEASURE
AUTOMATIC
USE -/+
'Y' TO SELECT
>SET DEFAULT CCA
AS: 600.
USE+/-
'Y' TO SELECT
You can also select the default rating to be
the last entered CCA value or a particular
amount such as 600 CCA.
CHARGE ONLY
REVIEW/PRINT
>SETUP
ABOUT
>SET CONTRAST
CONTRAST 4
USE +/-
'Y' TO SELECT
in order to select a menu line. It
also decrements a value.
N Esc
Key:
This key cancels a test or pro-
gression. It also returns to the
previous menu.
6.
Battery Temperature
Aim temperature probe at battery
and press button to input battery
temperature.
4.
Battery Test Sequence
Indicating Testing, 'Good', or 'Bad'.
5.
Battery Charge Sequence
Indicating Charging or Charged.