background image

RediPak

 & SmartPack

®

www.railroadpc.com

[email protected]

tel: 888-255.2755

©2016 Allcom Products Illinois, LLC.  All Rights Reserved.  

Allcom Products™ and Railroad Products™ are trademarks of Allcom Products Illinois, LLC.

Single Port for

WABTEC Next Gen 

®

Instruction Manual

RRP-433 Charger

Single Port for

End of Train Device 

plus

Battery Packs

                                                

 

                                           

 

 

 

 

                                                

 

              

 

     

 

     

 

            

 

     

 

 

 

 

                       

 

                                       

 

                                 

 

        

                              

~9 sec

 

STATUS Modes:

Healthy Battery [Mode 0]:

This is the normal mode for most batteries.  Once the CHARGE cycle is 
complete, the battery can be returned to service.

Battery Capacity Warning [MODE 1]:

After the charger has entered the Pulsed-Current float cycle, it will periodically  
check the battery capacity - approximately once an hour.  It does this by 
stopping the top-up pulses for a short duration and checking the battery 
terminal voltage response.  If the battery terminal voltage drops below the 
threshold level then the charger will go into [MODE 1].  Even if the unit 
detects a low battery capacity, it will continue to charge the battery.  
[MODE 1] is a warning that the battery capacity is getting low and may be 
nearing the end of its usable life.  

Before the battery is replaced, it should 

be checked by a calibrated battery tester.

Defective or Disconnected Battery [MODE 2]:

If the battery is disconnected or is defective, the charger will go into [MODE 2] 
and remain there until a healthy battery is connected.  

The charger will not 

charge a battery in this mode. 

 When a healthy battery is reconnected the 

charger will return to [MODE 1] and begin the charging cycle, unless a problem 
is detected.

Over Temperature [MODE 3]:

If a battery over temperature condition occurs, the charger will stop the charge
cycle and enter into [MODE 3].  The charger will periodically check the 
temperature of the battery and if the temperature drops below the maximum 
allowed temperature the charger will resume the charge cycle and return to 
[MODE 1].

Over Current [MODE 4]:

If an over current / short circuit condition is detected, the charger will stop the 
charge cycle and enter into [MODE 4].  This is considered a major fault condition.  
To protect the battery and the charger itself, the charger will need to be powered 
off and restarted to resume the charge cycle.

Charger Safety Features

Short Circuit Protection:

  Protects the charger from short-circuit damage.

Over Current Protection

:  Protects the charger from over-current demand.

Over Voltage Protection

:

  Protects the battery pack from damage.

Battery Polarity Reversal

:  Protects the charger and battery pack against  

 

  

incorrectly installed batteries.

Low Battery Voltage

: When the battery pack falls below 7V, the charger will 

 

 

 

not operate in Normal Charge Mode.

Charger Specifications

Input Voltage:  100-120VAC

Input Frequency:  47-63Hz

Output Voltage:  @Fast Charge: 14.4VDC;  Float: 13.6VDC
Output Current:  DC 1,000mA  (Fast Charge)

 

 

Battery Capacity:  5-20Ahr (recommended)

Operating Temp:  +32F/0C to +104F/40C

Storage Temp:  -4F/-20C to +140F/60C

Please check our website: 

www.allcompc.com

 for all applicable specifications,

and models pertaining to these series.