24
Next Page
If you are doing a generic test,
the screen will tell you to make
your connections. The large
clamps need to be connected
to the end of the cables you are
testing. The red clamp to the
positive end, black to ground.
The small clamps need to be
connected to the battery posts.
The small red clamp to the
b, the small black clamp
to the battery.
Select the V DROP Test from
the main menu.
Select Generic Cable Test.
Test in process, please wait.
To set the test current, press the
Test current box and a numeric
keypad will appear. Enter in the
test current for the circuit you are
testing. Press the Done button and
then press the Start Test button.
VOLTAGE DROP TEST (Generic Cable Test)