8
21
1
HOOK UP
Press the On/Off button: Connect the clamps as instructed on the LCD.
Enter the approximate battery
temperature in degrees Fahrenheit or Celsius (seen note) then press (Y
Enter).
Note:
Go to the setup to change temp scale to Celsius. The temperature
request only appears once for each battery tested. If the clamps are
disconnected you will be prompted again to begin a new battery test.
Note!
Take special care when connecting to battery side terminals.
If necessary use a side post adapter to prevent thread damage. When
testing dual post batteries always connect load clamps to the post to which
the system is attached. If a load test is made from a post connection
and the alternator is mounted to side terminals a battery load test can be
completed, but a continuity problem may still be in the side terminals when
testing the alternator.
CONNECTION ERRORS
If the clamps are reversed the Reversed Connection screen
will flash.
If one or both of the clamps are not in complete contact
(including both jaws) CHECK CONNECTIONS! will flash.
AUTO METER
BVA 350
SYSTEM ANALYZER
READY TO CONNECT
>ENTER BATTERY
TEMP 70F
USE +/-
‘Y’ TO CONTINUE