background image

8

9

  Use the side terminal feature on the clamp to connect battery side terminals.  

 

HOOK UP

2. 

Connect to only one 6-volt, 8-volt, or 12-volt battery at a time.

Red = (+) Positive and Black = 

(-) Negative

Make sure the terminals are 

clean and the connection is 

secure. If the "Check Battery 

Connections" remains the 

connections are not secure. 

If you are sure of a solid 

connection replace the battery.

1. 

Turn on the AC switch. The LCD will indicate "

DXC-2018CA" 

if the unit is properly plugged into an AC outlet. For your 

safety, make sure the AC receptacle is properly grounded. 

Note:

 

The DXC-2018CA is equipped with a 9ft power cord. Never use an 

extension cord smaller than 12 gauge or longer than 50ft. Make sure the 

extension cord and receptacle are properly grounded.

Note:

 

Due to gases and usual corrosion around the positive terminal 

it is important to connect the positive (+) red clamp first. Make sure 

the connection is certain. Then connect the negative (-) black clamp.

3. 

If the DXC-2018CA displays one of the following messages check your 

 connections.

Connect Black 

Clamp to Negative

 (-) Terminal

Connect Red 

Clamp to 

Positive (+) 

Terminal

REVERSED BATTERY

CONNECTIONS!

DISCONNECT NOW

CHECK BATTERY

CONNECTIONS!

‘N’ TO CANCEL

CHARGE SEQUENCE

From the menu select CHARGE using the +/- keys.

Then press 'Y' Enter to 

contine.

THE BATTERY 

NEEDS TO WARM

BEFORE CHARGE

'Y' TO CONTINUE

THE BATTERY 

IS TOO COLD TO

SAFELY CHARGE

'Y' TO CONTINUE

>ENTER BATTERY

 TEMP.     70F

 USE +/-

'Y' TO CONTINUE

The unit will go back to main 

menu.

The unit will go back to main 

menu.

THE BATTERY 

NEEDS TO COOL 

BEFORE CHARGING

'Y' TO CONTINUE

THE BATTERY 

IS TOO HOT TO

CHARGE SAFELY

'Y' TO CONTINUE

If the battery temperature is above 120°F the following message will appear.

If the battery temp is below 20°F the following message will appear

Use the +(Up) and -(Down) keys to enter the approximate battery temperature. The -(Up) and +(Down) keys 

increment & decrement in units of 10. 

Press 'Y' to continue.

>CHARGE

 REVIEW/PRINT

 SETUP

 ABOUT

Содержание AUTOZONE DXC-2018CA

Страница 1: ...018CA Charging The Xpress DXC 2018CA is the ultimate battery charger with fast charge and full charge options for the professional 2650 1934 77 1 9 18 T est Equipment Auto Meter Products Inc 413 West...

Страница 2: ...cturer s option to the consumer when determined by the manufacturer that the product failed due to defects in material or workmanship This warranty is limited to the repair or replacement of parts and...

Страница 3: ...the tester is off and the smart clamps are removed from the battery before cleaning SMART CLAMPS TM Both jaws of each clamp must firmly engage the battery terminal One copper jaw connects to the smal...

Страница 4: ...ge may result Incorrect Application Wrong size battery may have inadequate cold cranking Amp rating for original vehicle specifications Incorrect Installation Loose battery hold downs cause excessive...

Страница 5: ...ondition In addition the battery MUST have sufficient charge for testing Carefully perform the following before attempting any electrical diagnosis SETUP Scroll Down to Setup Select setup by pressing...

Страница 6: ...full charge to the battery AUTOMATED CONDITIONS The LED indicators will show the status during a fully automated Charge sequence This makes it possible to view the status and final results at a dista...

Страница 7: ...attery voltage 6V 8V or 12V Use Up or Down key to select rated battery voltage Press Y to continue After a short time the display will indicate the maximum time to complete the charge You can press N...

Страница 8: ...st Make sure the connection is certain Then connect the negative black clamp 3 If the DXC 2018CA displays one of the following messages check your connections Connect Black Clamp to Negative Terminal...

Отзывы: