background image

Warranty

AutoMate Scientific, Inc. warrants its products against defects of 

workmanship and/or material for ONE YEAR from the date of sale.  Any 

product that fails to perform as specified may be returned, freight pre-paid 

to the factory (with a written explanation of the problem) for examination 

and repair or replacement.  If it is defective, AutoMate Scientific will repair 

or replace (at our option) the product without charge and return it to you.

If the examination indicates that non-compatible fluid, destructive 

environment, accidental damage, modification or abusive practices have 

occurred, all labor, materials and freight costs shall be at the expense of the 

customer.

Due to the nature of clinical laboratory applications, AutoMate Scientific, 

Inc. will NOT accept the return of any products which have been used with 

HAZARDOUS MATERIALS or harmful environment.

This warranty is in lieu of all other warranties, whether oral or written, 

express or implied.  In no event shall AutoMate Scientific, Inc. or its 

licensor/licensees be liable for contingent, special, direct, indirect or 

consequential damages for the breach of any express or implied warranty 

or resulting from the use, failure or malfunction of any product, including 

damage to property and, to the fullest extent permitted by law, damages 

for personal injury, even if AutoMate Scientific, Inc. has been advised 

of the possibility of such damages or if this warranty is found to fail its 

essential purpose.  AutoMate Scientific, Inc’s liability is limited to the 

reimbursement of the cost of the product.  All other warranties, including, 

but not limited to warranties for fitness or merchantability for a particular 

purpose are expressly excluded. No verbal changes to this policy will be 

authorized.

AutoMate Scientific, Inc. manufacturers and sells goods in accordance with 

U.S. federal, state and local laws, but assumes no responsibility or liability 

for laws, regulations, duties, or taxes imposed by any foreign country.  All 

terms and conditions hereof shall be governed by the laws of the State of 

California.

AutoMate Scientific

®

R E A D Y F O R R E S E A R C H.

TM

 

 

European CE Technical Representative:

 

 

AutoMate Scientific

 

 

An der evang. Kirche 2, Bonn 53113, Germany

43

42

Содержание ValveLink 8.2

Страница 1: ...ValveLink8 2 User s Manual AutoMate Scientific R E A D Y F O R R E S E A R C H TM...

Страница 2: ...ve Tubing Valve Care Perfusion Pencil Flow Rates Perfusion Pencil Multi barrel Manifold Perfusion Pressure Kit Josef Kewekordes II Heath Lukatch Dave Blau ValveLink8 2 Part 01 18 For indoor use only f...

Страница 3: ...RCA jacks on the back of the box Why not connect valves directly to your computer Several reasons 1 Most computer interfaces provide 5V signals not strong enough to drive most valves 6 to 12V DC and h...

Страница 4: ...wheels and pipette pullers ValveLink8 2 Laboratory Applications Perfusion A ValveLink8 2 can be programmed to precisely switch solutions perfusing over biological samples for physiological research T...

Страница 5: ...on inline heater plus multi channel focal drug delivery maintain bath temperature and rapid drug wash out with a high flow bath line while quickly switching 4 8 preheated solutions through the Perfusi...

Страница 6: ...ld also see the photo on page 5 Find additional photos and diagrams of the pressure system on page 15 2 3 4 1 Assemble ringstand base and rod 2 Attach valve unit 3 Insert syringes with stopcocks Pinch...

Страница 7: ...ine directly to the outflow of the manifold for running cleaning solutions and drying your lines quickly Determine dead volume from the manifold to prep by measuring time and volume required to flush...

Страница 8: ...e Tips reservoir height 40cm Gravity 0 2psi air pressure 0 07ml min 4 6ml hour 8psi air pressure 0 25ml min 15ml hour PTFE Micro manifold Use To use the micro manifold you either need pinch valves or...

Страница 9: ...and removable tips are shipped non sterile They can be chemically sterilized or autoclaved However repeated autoclaving may weaken the adhesive bond between the luer lock fitting and the needle Maint...

Страница 10: ...es mirroring the computer signals low off high on with one millisecond accuracy Usually data acquisition software like pClamp Pulse LabView etc or custom user software is programmed to send digital si...

Страница 11: ...nt panel analog output BNC as an event marker every time a valve opens or closes The marker voltage occurs regardless of how the valve was opened or closed i e manual pushbutton or computer digital in...

Страница 12: ...an electrical path for the spill sensor circuitry In this way a drop of liquid passing the sensor strip appears as a sharp drop in electrical resistance between the two otherwise disconnected copper c...

Страница 13: ...traces A similar conductive epoxy is also available It makes the connection of two wires to your silver traces even easier Simply draw two parallel silver lines approximately 1 16 1 mm apart on any s...

Страница 14: ...between two ValveLink8 2s and control up to 16 valves with a single 4 bit TTL source Set the first ValveLink8 2 to Mode 2 set the second to Mode 3 and connect TTL input bits 1 4 from both ValveLink8 2...

Страница 15: ...ur version of Windows the first time a ValveLink8 2 is installed by USB cable Windows will find new hardware A dialog box will appear asking if you want Windows to connect to Windows Update to search...

Страница 16: ...on rotary switch on the back of each ValveLink8 2 next to its USB port If you connect multiple ValveLink8 2s to the computer be sure to set each one to a different address If you connect a ValveLink8...

Страница 17: ...one valve will be open at a time on all of the networked controllers When the System Status switch is set to Local Control you can click the Mode button on any ValveLink8 2 sub window to access a dia...

Страница 18: ...ar as BNC connectors on the front panel Digital outputs 4 7 are located on the back panel of newer DigiData interfaces Older DigiData 1200 s only have four outputs 2 The Modes chapter explains the two...

Страница 19: ...tubing at an angle and wetting it makes it easier to insert Backflow When a manifold is used in a plumbing arrangement none of its ports can be left unconnected or liquid will simply flow backwards o...

Страница 20: ...g see 1 above and the section below If it qualifies for all three of the above AutoMate Scientific will accept the valve for subsequent return to the factory Repair or replacement is at their discreti...

Страница 21: ...e Safety and Handling data sheets for the above described chemicals are enclosed c We accept full responsibility for any injury to AutoMate Scientific employees or employees of the valves original man...

Страница 22: ...e power requirements of this product 6 Do not allow anything to rest on the power cord Do not locate this product where people will walk on the cord 7 If you have to use an extension cord with this pr...

Страница 23: ...nsor licensees be liable for contingent special direct indirect or consequential damages for the breach of any express or implied warranty or resulting from the use failure or malfunction of any produ...

Страница 24: ...entific Inc 812 Page St Berkeley CA 94710 U S A 800 998 MATE 6283 international 510 845 6283 fax 510 280 3795 e mail info autom8 com www http www autom8 com AutoMate Scientific R E A D Y F O R R E S E...

Отзывы: