12
Australian
Technology
AISLG500.PCB
GND
24VDC
Out
I.R
COM
24VDC
Terminal X2
Infrared
Control board
Infrared with DC input
Signal
Wiring notes of control board
a. Power Input(X1) : E (Earth), L (Live), N (Neutral).
b. Caution light : connect caution light wire to D1 and D2(terminal X3)
c. Output power supply : 24VDC, COM (COM), I.R. (N.C Infrared) If the infrared beam is interrupted
during closing, the gate will reverse and open immediately. The product is not factory equipped
with an infrared device, the infrared output signal must be N.C.
Verify open direction :
If the gate does not move in the desired direction, then you will need
to reverse the motor operating direction, open the plastic cover, you can do this by exchanging
wires ‘U’ and ‘W’, ‘OPLM’ and ‘CLLM’.
Remote control : The remote control works in a single channel mode. It has four buttons.
The function of button 1, button 2, button 3 and button 4 are the same. With each press of the
remote control button which has been programmed, the gate will close, stop, open.