![Autel Maxi US AC W12-H Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/autel/maxi-us-ac-w12-h/maxi-us-ac-w12-h_installation-manual_3020288004.webp)
The MaxiCharger AC Wallbox Home can also be wired for higher amperages. Consult all applicable codes for breaker and
wire sizing requirements. The field-wiring terminal is rated to 105 ˚C and accepts a maximum of 16 mm² (6 AWG) wire.
2. For NEMA plug-in installation, determine the purchased plug type, either a NEMA 6-50 or 14-50 plug.
4. The recommended installation height is between 51 and 67 inches (1300 and 1700 mm). For NEMA plug-in installation,
the NEMA outlet should be located at least 18 inches (460 mm) from the ground adjacent to the position where the char-
ger will be mounted.
3. Ensure the electrical panel supports a 240 V dedicated circuit with a new, dedicated, and non-GFCI two-pole circuit breaker,
in accordance with local codes and ordinances.
IMPORTANT:
A NEMA plug-in installation is only allowed with a 50 amp circuit.
Circuit Rating
80 A
70 A
50 A
50 A
Up to 45 miles/72 km
Up to 45 miles/72 km
no
no
yes
yes
Max Load
Estimated Range per Hour
NEMA Plug-in
Hardwire
NEMA Plug-in Version
Charger Height
43"–59"
(1100–1500 mm)
11.8"
(300 mm)
Cable length
Outlet Height
51"–67"
(1300–1700 mm)
Recommended
Recommended
Hardwire Version