background image

2

Receiving

unit

Transmitting 

unit

INTRODUCTION TO E16 SERIES

Each E16 series radio remote control is in conformity

with the R&TTE 99/05/CE Directive and all its essential requisites. 

Each radio remote control is also in conformity with the norms 

given in the EC conformity declaration present in this manual.

Page 2

!

PERMITTED 

USES: Material 

lifting machines 

(construction cranes, 

industrial bridge cranes, 

concrete pumps, 

machines for 

moving material in 

general, . . . )

Industrial radio remote controls of the E16 series are 
used to command machines from a distance.  Each 
industrial radio remote control is made up of a portable 
transmitting unit, from which the user can remotely 
control the machine, and a receiving unit installed on 
board the machine itself.
The transmitting unit uses radio frequencies to 
transmit a coded message which contains a value 
called address.  Each receiving unit can only decode 
the messages coming from a transmitting unit with the 
same address.
This excludes the possibility of an interference 
activating any system function.  If the radio frequency 
transmission is disturbed, incorrect or interrupted, the 
receiving unit autonomously stops the whole system.

To guarantee correct radio remote control operation, all current regulations regarding 
safety at work and accident prevention should be respected. All current user country 
national laws regarding the use of both the machine and the radio remote control MUST 
ALWAYS be respected.

Autec cannot be held responsible if the radio remote control is installed on 
applications that are different from those permitted or if used in working 
conditions that do not respect prescribed standard.

LIE16MU1

!

FORBIDDEN 

USES: Machines 

installed in areas 

where equipment with 

explosion-proof charac-

teristics are being used 

Machines for moving, 

raising and 

transporting 

people

Содержание E16 Series

Страница 1: ...ing the radio remote control this manual MUST be read and understood carefully by all people who install use and carry out maintenance on the radio remote control If this manual is lost or damaged ask for a copy from Autec Please specify the serial number of the relative radio remote control Follow the indications and warnings given by the machine producer regarding the machine controlled by the r...

Страница 2: ... message which contains a value called address Each receiving unit can only decode the messages coming from a transmitting unit with the same address This excludes the possibility of an interference activating any system function If the radio frequency transmission is disturbed incorrect or interrupted the receiving unit autonomously stops the whole system To guarantee correct radio remote control...

Страница 3: ...UARANTEE TECHNICAL DATA SHEET IDENTIFICATION PLATES The conditions of the radio remote control guarantee are given in the Certificate of Guarantee contained in this manual The electronic components which have a 3 year guarantee are E16TXEU_ E16RXEU_ and E16CHEU_ The technical data sheet shows the wiring system between the receiving unit and the machine It should be compiled and checked by the inst...

Страница 4: ...Hz 8 10 exp 11 100 m 20 C 70 C 100 ms 100 ms 1 second optional 0 5 s Frequency range Programmable radio channel Channel spacing Hamming distance Probability of non recognition of error Typical working range Working temperature Time of reply to commands Time of reply to STOP Passive emergency time LIE16MU1 ...

Страница 5: ...given in the receiving unit manual TypeE16URX TypeE16URQ Page 5 The E16 series is equipped with a safety function called SAFETY which protects the radio remote control machine system from involuntary movements caused by possible radio remote control faults A starting keyswitch E STOP button B green signalling LED F identification plate C actuators joystick and selector G START pushbutton D technic...

Страница 6: ...h or NiMH 7 2V 1 3 Ah internal 10 mW ERP 5 mW ERP nylon 20 fg IP65 263x160x173 mm 1 4 kg 15 hours 7 minutes SIRIO E CONDOR E TRANSMITTING UNIT TECHNICAL DATA Power supply battery pack Antenna Transmitting power frequency 433 MHz Transmitting power frequency 870 MHz Housing Minimum protection grade Dimensions Weight Autonomy with fully charged battery at 20 C Warning of low battery charge Page 6 LI...

Страница 7: ...rk area Press the STOP button in case of hazard ONLY SWITCH ON OR USE the transmitter unit when starting work improper use could be hazardous SWITCH OFF the transmitter unit when work is interrupted Avoid leaving the load suspended in the air even when changing the battery NEVER SWITCH ON OR USE the transmitter unit in closed spaces with the machine not in sight or outside the typical range of act...

Страница 8: ...t contact anyone other than our Assistance Service In order to make the intervention faster and more reliable please help us identify the radio remote control correctly and completely by giving the serial number the purchase date given on the guarantee description of the problem found the address and telephone number of the place where the radio remote control is being used the name of the person ...

Страница 9: ...eactivate it and repeat the power o n a n d s t a r t i n g procedure The STOP button should be used when it is necessary to stop the machine immediately in order to check any danger condition COMMAND ACTIVATION TYPE OF SIGNAL MEANING OF SIGNAL ACTION NECESSARY Slow flash OPERATION NORMAL Fast flash LOW BATTERY The transmitter unit switches off approx 7 minutes after the LED starts flashing Switch...

Страница 10: ...F CHARGE indicator switches off the battery is fully charged Remove the battery from the charger if the battery is not removed charging continues in maintenance mode 2 CHARGING THE BATTERY The transmitting unit should be switched off each time work is stopped by turning the ignition key to O and extracting it always put the key in a safe place The unit may also switch off if the battery is not suf...

Страница 11: ... which a radio remote control can be programmed belongs to the set of frequencies permitted by national standards that are valid at the moment of entry into the market Each radio remote control is programmed by the producer in the AUTOMATIC scanning or MANUAL selection mode The use of 433 050 434 790 Mhz band frequencies has not yet been harmonised in Europe check for possible user s country limit...

Страница 12: ... 7 870 MHz 12 frequencies available DIP SWITCH ON RADIO MODULE The eight dip switches on the transmitter module are for programming various functions and setting the operating frequency SETTINGS OFF DIP ON The transmitter unit switched on without commands entered switches off after 7 minutes 1 The transmitter unit never switches off automatically Activation of low battery warning from horn on mach...

Страница 13: ...the radio remote control In this case proceed as follows ENGLISH Is the led on with a steady light Is the STOP button or one of the movement actuator inserted Release it them The battery is discharged replace it with one that is charged Does it continue to blink quickly Clean the contacts in the battery seat Does it continue to blink quickly Does the led blink quickly If the problem persists CALL ...

Отзывы: