1.3 Intended Application

This manual applies to the following products;

S2.1P-SMARTMETER

For 1 phase inverters

Please note that all current inverter models excluding the UX Series are capable of internal power export
limitation using an external  current clamp or consumption meter.  The internal PELD functionality is only
applicable for systems with one inverter. Please see the relevant inverter series manual for more
information. External power export limitation with the help of the PELD  is possible with all inverters.

2. Preparation

2.1

Safety instructions

DANGER! Do not touch any internal components whilst the inverter is in operation.

NOTICE! Do not directly connect AC output of the inverter to any private AC equipment. The PV
inverter is designed to feed AC power directly into the public utility power grid.

WARNING! The installation, service, recycling and disposal of the inverters must be performed by
qualified personnel in compliance with national and local standards and regulations.
Please contact your dealer to get the information of an authorized repair facility for any maintenance
or repairmen.

Any unauthorized actions including modification of product functionality of any form will affect the
validation of warranty service; Autarco may deny the obligation of warranty service accordingly.

5

Содержание S2.1P

Страница 1: ...Installation and Operation Manual Consumption meter IM S2 1P SMARTMETERI EN V1 0 Manual...

Страница 2: ...This manual is an integral part of the unit Please read the manual carefully before installation operation or maintenance Keep this manual for future reference Product information is subject to chang...

Страница 3: ...1 3 Intended Application 5 2 Preparation 5 2 1 Safety instructions 5 3 Overview 5 3 1 Front Panel Display 6 3 2 LED Status Indicator Lights 6 4 Installation 7 4 1 Mounting the Consumption meter 7 4 2...

Страница 4: ...llowed could result in burns 1 2 Target Audience This manual is intended for anyone who installs or maintains Autarco inverters in conjunction with a Consumption meter Before any further action the op...

Страница 5: ...tions DANGER Do not touch any internal components whilst the inverter is in operation NOTICE Do not directly connect AC output of the inverter to any private AC equipment The PV inverter is designed t...

Страница 6: ...front panel of the consumption meter as shown in figure 3 1 Light Status Description Run GREEN FLASHING Device is on OFF Device id off Com FLASHING Communication with inverter OFF No communication wit...

Страница 7: ...4 Installation 4 1 Mounting the Consumption meter The consumption meter needs to be installed in the meter cupboard and can be installed on a 35mm DIN 35 rail 4 2 Electrical Connections 7...

Страница 8: ...upplied RS485 cable to the meter port of the inverter You can only use the RJ45 port for connecting the consumption meter to the inverter Install the current clamp on the phase cable that goes to the...

Страница 9: ...anged Use the up and down buttons on the inverter to navigate the menu Go to Advanced settings Select 24h Switch Set to ON and press ENTER Go to Internal EPM set Mode Select Select Consumption Monitor...

Страница 10: ...ogy 1P N Rated Voltage 220V 230V Input Current 40mA External CT 120A 40mA Accuracy Voltage 0 2 Current 0 5 Power P Q S 0 5 Active Energy 0 5 Reactive Energy 1 Operating Temperature 10 C 55 C Relative...

Отзывы: