1. Introduction

1.1 Read this first

This manual contains important information for use during installation and maintenance of the
Consumption meter with Autarco’s inverters.

To reduce the risk of electrical shock, and to ensure the safe installation and operation, the following safety
symbols appear throughout this document to indicate dangerous conditions and important safety
instructions.

WARNING! Indicates safety instruction, which if not correctly followed, can result in injury
or property damages.

RISK OF ELECTRIC SHOCK! Indicates safety instructions, which if not correctly followed,
could result in electric shock.

HOT SURFACE! Indicates safety instructions, which if not correctly followed, could result
in burns.

1.2 Target Audience

This manual is intended for anyone who installs or maintains Autarco inverters in conjunction with a
Consumption meter. Before any further action, the operators must first read all safety regulations and be
aware of the potential danger to operate high-voltage devices. Operators must also have a complete
understanding of this device’s features and functions.

ATTENTION! Qualified personnel means a person with valid license from the local authority in:

Installing electrical equipment and PV power systems (up to 1000 V).

Applying all applicable installation codes and using Personal Protective Equipment.

Analyzing and reducing the hazards involved in performing electrical work.

WARNING! Do not use this product unless it has been successfully installed by qualified personnel in
accordance with the instructions in chapter 4 “Installation”.

4

Содержание S2.1P

Страница 1: ...Installation and Operation Manual Consumption meter IM S2 1P SMARTMETERI EN V1 0 Manual...

Страница 2: ...This manual is an integral part of the unit Please read the manual carefully before installation operation or maintenance Keep this manual for future reference Product information is subject to chang...

Страница 3: ...1 3 Intended Application 5 2 Preparation 5 2 1 Safety instructions 5 3 Overview 5 3 1 Front Panel Display 6 3 2 LED Status Indicator Lights 6 4 Installation 7 4 1 Mounting the Consumption meter 7 4 2...

Страница 4: ...llowed could result in burns 1 2 Target Audience This manual is intended for anyone who installs or maintains Autarco inverters in conjunction with a Consumption meter Before any further action the op...

Страница 5: ...tions DANGER Do not touch any internal components whilst the inverter is in operation NOTICE Do not directly connect AC output of the inverter to any private AC equipment The PV inverter is designed t...

Страница 6: ...front panel of the consumption meter as shown in figure 3 1 Light Status Description Run GREEN FLASHING Device is on OFF Device id off Com FLASHING Communication with inverter OFF No communication wit...

Страница 7: ...4 Installation 4 1 Mounting the Consumption meter The consumption meter needs to be installed in the meter cupboard and can be installed on a 35mm DIN 35 rail 4 2 Electrical Connections 7...

Страница 8: ...upplied RS485 cable to the meter port of the inverter You can only use the RJ45 port for connecting the consumption meter to the inverter Install the current clamp on the phase cable that goes to the...

Страница 9: ...anged Use the up and down buttons on the inverter to navigate the menu Go to Advanced settings Select 24h Switch Set to ON and press ENTER Go to Internal EPM set Mode Select Select Consumption Monitor...

Страница 10: ...ogy 1P N Rated Voltage 220V 230V Input Current 40mA External CT 120A 40mA Accuracy Voltage 0 2 Current 0 5 Power P Q S 0 5 Active Energy 0 5 Reactive Energy 1 Operating Temperature 10 C 55 C Relative...

Отзывы: