background image

INTEGRATED GUARD UNIT CENTRAL

 

 

 

 

 

12

User Guide 

 

 

Calls stored in the queue can only be deleted if they are manually erased (pressing 

Æ

), or if a call is returned and the conversation is established (if it is not, the call 

will remain queued). Once all the calls have been erased, the screen will show that 
the queue is empty and the switchboard will return to the main menu. 

 

Figure 7

. Example with 2 calls stored in the queue. 

 

4.3.  Settings: 

 

This menu allows adjusting settings related to the manner the SB operates according to the 

user preferences. 

 

4.3.1. Operating Mode: 

 

Operating modes determines the way the SB reacts to the incoming calls from the 

outdoor panels

:  

 

 

Standard Mode:

 The switchboard receives all the incoming calls made from the 

panels. If they are not attended during the next 30 seconds, they will be 
automatically passed through to the appropriated flat. 

 

 

Direct Mode:

 All the incoming calls made from the panels will be automatically 

passed through to the flats. The switchboard will show on screen information about 
the incoming call, but it won’t be able to interfere. If the SB receives a non-stored 
code in its database, it will manage it as “Call to Switchboard” (the incoming call 
won’t be passed through to any flat). 

 

 

Not Disturb:

 It works the same way as the Standard Mode, but if the incoming 

calls are not attended during the first 30 seconds, they won’t be passed through to 
the flats. 

 

 

Manager Mode:

 The switchboard only receives incoming calls from other 

switchboards, never from outdoor panels or flats. However it can call the flats, the 
rest of the switchboards and/or execute a self-start over the outdoor panels

5

 

This is a special mode that requires to be enabled from the configuration menu 

(see chapter 4.4). 

 

                                                 

5

 Only over panels with this feature enabled. See panel manual. 

 

 

 

 

 

 

 

 

auta 

Cod: 0

 

00025

 

 

  

1

 

/

 

2

 

Enrique  Simon

 

 

  

2º izda

 

Queue

 

 

 

(

 

 

 

 

 

Navigate

 

  

 

  OK  Call

 

Å

 

  Exit

 

 

  

 

  

  

Æ

    

Erase

 

Содержание CENTRAL COMPACT INTEGRADA

Страница 1: ...CENTRAL COMPACT INTEGRADA INTEGRATED GUARD UNIT CENTRAL HI 86 02 05 AUX 1 2 3 4 5 6 7 8 9 0 LLAMANDO A 120506 HI 91 12 06 COMPACT COMPACT ENGLISH...

Страница 2: ...nillos suministrados 2 Embornar los cables 3 Conectar la central con el latiguillo al circuito del m dulo de conexi n 4 Colgar la central en la plancha fijada en la pared 1 Fix the bracket to the wall...

Страница 3: ...chboard powered up Main Features Small size suitable for desk installation Able to manage up to 1024 flats Capability to install more than one SB with communication among then Data load from PC Automa...

Страница 4: ...configuration menu see chapter 4 4 To explain the functioning of the switchboard we must differentiate 2 kinds of users On one side the guard porter and on the other side the installer or the owner T...

Страница 5: ...ime this button is pressed the Aux2 output of the module of connections is activated for 100 ms activation pulse There is a blue led blue lamp that brings information about the system state because it...

Страница 6: ...enter the main menu and then select the Directory option pressing OK Once in the directory keys can be used to navigate across the directory looking for the suitable register When found pressing OK w...

Страница 7: ...and it will display this data on the screen If the guard porter doesn t attend the call picking up the handset it will be stored in the queue If the guard porter rejects the call pressing key 1 withou...

Страница 8: ...through the directory using or typing a valid call code and then OK Once the correct register is found it is possible to pass the call pressing or perform a consult to the flat with these two function...

Страница 9: ...en loaded in the database of the switchboard will be understood as Call to Switchboard On screen the number of the calling panel will be shown and also the identification of Phone Monitor 0 and of SDL...

Страница 10: ...the convenience of passing the call through or not So after have talked to the outdoor panel the guard porter contacts with the flat At that moment switchboard and flat have both the same video pictur...

Страница 11: ...o 15 To exit this menu the door release key must be pressed To perform the call pick up the handset and press OK The call will be performed in a similar way than if it was a call to a flat Call from Q...

Страница 12: ...d directly from the Stand By state pressing key The SB stores up to 25 missing calls These calls can be from flats or switchboards but not from panels Calls are stored according to the order they have...

Страница 13: ...ough to the appropriated flat Direct Mode All the incoming calls made from the panels will be automatically passed through to the flats The switchboard will show on screen information about the incomi...

Страница 14: ...ones are defined by three parameters Type There are 8 different kinds of ringtones Number of Ringtones Times the ringtone is repeated From 0 mute to 4 Volume There are 3 volume levels The value of the...

Страница 15: ...cal arrows advance go back as in the Directory menu but having access to the complete information of each register Unlike the previously explained Directory menu it is not possible to call to the flat...

Страница 16: ...the way explained previously Remote Entry With this method the registers are loaded from a PC This way it is possible to load complex directories really fast Before proceeding to load the database of...

Страница 17: ...ossible to start up an installation in a very fast and simple way The SB follows this process First of all the SB will ask if it is desired to erase the current directory This is advisable to avoid th...

Страница 18: ...the directory and erasing the register shown on the screen Before erasing the register the SB will ask for confirmation to do it Entire Directory This way all the registers in the directory are erase...

Страница 19: ...llation These parameters are Pull Up Type Pull Up It can be connected ON or disconnected OFF So that the digital system works it is necessary a Pull Up connected in the line of communications Normally...

Страница 20: ...ACCESSES Vo Vi HI 86 02 05 AUX 1 2 3 4 5 6 7 8 9 0 LLAMANDO A 120506 BUS GENERAL ACCESO PRINCIPAL MAIN ACCESS Coaxial Tipo Type RG 59 75 Secciones de hilos Wiring sections Hasta 100 m UP to 100 m Has...

Страница 21: ...INTERIOR ACCESSES Vo Vi HI 86 02 05 AUX 1 2 3 4 5 6 7 8 9 0 LLAMANDO A 120506 BUS GENERAL ACCESO PRINCIPAL MAIN ACCESS Coaxial Tipo Type RG 59 75 Secciones de hilos Wiring sections Hasta 100 m UP to 1...

Страница 22: ...GRADA ES COMPATIBLE CON LAS SIGUIENTES VERSIONES DE MODULO DE CONTROL 600005 M C DIGITAL 1 4 o POSTERIOR 600006 M C TECLADO 1 8 o POSTERIOR 600007 M C SDL 1 5 o POSTERIOR 730121 SDL 1 1 o POSTERIOR 60...

Отзывы: