background image

 
 
Clou Pellet / Clou Compact Pellet User instruction 

30

 

English

 

 

 

10

 

Technical data 

 

 

Clou Pellet 8 kW / 10 kW 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

Distance to combustible parts 
 
 
 
 
 
 

 

Nominal heat efficiency (NHE) 

 

 

8 / 10 kW 

Heat output at partial load (PL) 

 

 

2,4 / 2,4 kW  

Room-heating capacity 

 

 

98 - 255 / 128 

 350 m³ 

Efficiency 

 

 

 

≥90 %

 

CO content at NHE 

 

 

 <250 mg/Nm³ 

Flue gas temperature at NHE  

 

 

200 / 229 °C 

Flue gas temperature at PL 

 

106 / 106 °C 

Exhaust gas mass flow at nominal heat efficiency 

 

 

5,51 / 6,18 g/s 

Chimney draught 

 

 

3-12 Pa 

Filling tank capacity 

 

 

36 kg / 56 l 

Pellet consumption min./max. 

 

 

0,6 

 1,87 / 0,71 

 2,36 kg/h 

Burning time min./max. 

 

 

≈19 –

 

60 / ≈15

-50 h 

Air inlet nozzle Ø 

 

 

80 mm 

Flue gas outlet Ø 

 

 

80 mm 

Electrical power consumption when switching on

 

   

 

300 W 

Electrical power consumption during operation 

 

 

<20 W 

Voltage / current frequency 

 

 

230 V / 50 Hz 

Dimensions 

H x W x D 

 

1100 x 630 x 510 mm 

Weight 

 

 

173 kg 

Minimum clearance 

at the side 

(wall) 

100 / 150 mm 

 

 

rear 

100 / 100 mm 

 

 

front 

800 / 1000 mm 

Temperature limits 

 

 

 40 °C 

Relative humidity 

 

 

non-condensing  

Содержание Clou Compact Pellet

Страница 1: ...Benutzerhandbuch User instructions Istruzioni per l uso Manuel d instructions Clou Pellet Clou Compact Pellet...

Страница 2: ......

Страница 3: ...Clou Pellet Clou Compact Pellet User instruction 1 English...

Страница 4: ...ith modulation 15 4 5 2 External thermostat 15 Function diagram 16 5 Alarms and error messages 17 Clearing alarm error messages 20 Fill level indicator 20 Safety temperature limiter 21 6 Replacing the...

Страница 5: ...Clou Pellet Clou Compact Pellet User instruction 3 English 14 Start up log 43 15 Service Report 45...

Страница 6: ...ny kind or residues may be burnt in the stove Only pellets of ENPlus quality see section on fuel may be burned It is forbidden to place non heat resistant objects on or near the appliance Do not place...

Страница 7: ...glish Please note that the installation room must have at least one door one window leading to the out side or be directly connected to such a room Other heating appliances and extractor hoods may not...

Страница 8: ...t be more than 3 m and have a maximum of three elbows When connecting directly to the outside wall it is important to ensure that condensation does not form in the process Austroflamm offers appro pri...

Страница 9: ...erent residues in the burn pot of the pellet stove when burning We therefore strongly recommend using pellets that do not contain artificial binding agents and there fore generate minimal unburnt resi...

Страница 10: ...ptional WLAN BOX using the Austroflamm PelletControl app INFORMATION Fuel quality 1 represents the highest possible quality Fuel quality 3 is the poorest quality Your stove is set to fuel quality 2 ex...

Страница 11: ...ated your stove gradually reduces the heat output to the lowest level when the room setpoint temperature has been reached However it does not switch off despite reaching the desired room temperature I...

Страница 12: ...s phase and ensure that the room is well ventilated In order for the varnish to cure quickly we recommend running the stove at the highest power setting for 3 4 hours when it is first put into operati...

Страница 13: ...rature in the firebox is sufficiently high To achieve the necessary high temperatures in the firebox for the Keramott to burn cleanly you must operate the pellet stove e g after the automatic start wh...

Страница 14: ...tes the completion of the start phase by means of a permanently lit green flame Your pellet stove is now ready for your desired power setting You can also start your pellet stove with the optional WLA...

Страница 15: ...al heat output in 5 levels Simply turn the dialing knob to the desired power level The illuminated field shows the set power level After setting the power level your selection will be confirmed after...

Страница 16: ...ve using the smartphone Austroflamm PelletControl app IMPORTANT To be able to operate your pellet stove using the optional WLAN BOX the dialing knob must first be set to the 3 o clock position Only af...

Страница 17: ...ntrolling the heat out put The SmartSpot is available in neutral white and in a high quality wood aluminium finish It is important that the SmartSpot is installed by an authorised Austroflamm technici...

Страница 18: ...Clou Pellet Clou Compact Pellet User instruction 16 English Function diagram...

Страница 19: ...rating hours is specified for the stove After this period has elapsed the stove signals via ALARM that a service is due Maintenance of the stove must be carried out by an authorised Austroflamm servic...

Страница 20: ...an is damaged obstructed or dirty Clear the ERROR Restart your stove If the error persists contact your Austroflamm service engi neer Error E107 Firebox sensor is de fective The temperature sensor in...

Страница 21: ...oflamm service engineer for a solution Error E114 The temperature in the firebox is too low Possible causes for this message are 1 The pellet hopper is empty Check the level in the fuel tank Refill th...

Страница 22: ...cture The reset button can be accessed underneath the tank cap Reset button The reset button is accessible at the front right after opening the tank cap The fuel level alarm can be acknowledged using...

Страница 23: ...ind If the battery is flat the control unit will function normally as long as it is connected to the mains power supply However in the event of a power failure the internal clock will stop and the ope...

Страница 24: ...oiling Maintenance work at the end of the service free operating hours must be carried out by an authorised ser vice engineer Maintenance is essential after the service due date service counter has ex...

Страница 25: ...the firebox and the burn pot The following CLEANING OPERATIONS may only be carried out by an authorised service engineer 7 1 2 Cleaning the flue gas passes Lift up the inspection lid Remove the faste...

Страница 26: ...panel Remove the cleaning cover and vacuum the flue gas area Dismantle and clean the flue gas fan After cleaning the SERVICE ENGINEER will RESET the OPERATING HOUR COUNTER which is essential This is f...

Страница 27: ...your pellet stove Noise of this kind does not constitute a warranty claim and do not constitute a warranty claim The territorial scope of validity of our guarantee covers Austria Germany and France I...

Страница 28: ...ch 3 RPM HAL IC 4 Room temperature sensor 5 Firebox temperature sensor 6 Differential pressure measurement 7 Central grounding 8 Controller grounding 9 Ceramic ignition 10 Combustion fan 11 Feeder mot...

Страница 29: ...Clou Pellet Clou Compact Pellet User instruction 27 English Models with an ON OFF feeder motor...

Страница 30: ...Clou Pellet Clou Compact Pellet User instruction 28 English Detailed electrical wiring diagram 9 3 1 Power splitter 9 3 2 Combustion fan...

Страница 31: ...Clou Pellet Clou Compact Pellet User instruction 29 English 9 3 3 Room temperature sensor and SmartSpot 9 3 4 Model with a permanently rotating feeder motor...

Страница 32: ...mass flow at nominal heat efficiency 5 51 6 18 g s Chimney draught 3 12 Pa Filling tank capacity 36 kg 56 l Pellet consumption min max 0 6 1 87 0 71 2 36 kg h Burning time min max 19 60 15 50 h Air i...

Страница 33: ...act Address Austroflamm Platz 1 4631 Krenglbach Austria Appliance details Model identification s Clou Pellet 8 kW Equivalent models Test reports DBI F 19 04 0656 by 1721 DBI Applied harmonized standar...

Страница 34: ...ture content 25 no no Compregnated laminated wood Moisture content 12 yes no 87 6 15 1 24 108 12 6 117 115 Other woody biomass no no Non woody biomass no no Anthracite and dry steam coal no no Coking...

Страница 35: ...esent Ppilot kW with electronic room temperature control and day time regulation no with electronic room temperature control and weekday regulation yes Other regulation options Multiple answers possib...

Страница 36: ...s Austroflamm Platz 1 4631 Krenglbach Austria Appliance details Model identification s Clou Pellet 10 kW Equivalent models Test reports DBI F 19 04 0656 by 1721 DBI Applied harmonized standards EN 147...

Страница 37: ...ture content 25 no no Compregnated laminated wood Moisture content 12 yes no 87 6 19 1 41 112 12 6 117 115 Other woody biomass no no Non woody biomass no no Anthracite and dry steam coal no no Coking...

Страница 38: ...esent Ppilot kW with electronic room temperature control and day time regulation no with electronic room temperature control and weekday regulation yes Other regulation options Multiple answers possib...

Страница 39: ...mass flow at nominal heat efficiency 4 78 g s Chimney draught 3 12 Pa Filling tank capacity 26 kg 40 l Pellet consumption min max 0 5 1 55 kg h Burning time min max 16 52 h Air inlet nozzle 80 mm Flu...

Страница 40: ...Austroflamm Platz 1 4631 Krenglbach Austria Appliance details Model identification s Clou compact Pellet Equivalent models Test reports 1880 CPR 049 21 at 1880 Acteco Applied harmonized standards EN...

Страница 41: ...ture content 25 no no Compregnated laminated wood Moisture content 12 yes no 84 8 12 7 8 121 12 7 109 105 Other woody biomass no no Non woody biomass no no Anthracite and dry steam coal no no Coking c...

Страница 42: ...esent Ppilot kW with electronic room temperature control and day time regulation no with electronic room temperature control and weekday regulation yes Other regulation options Multiple answers possib...

Страница 43: ...805005 SmartSpot sensor premium 800012 optional WLAN BOX 640170 Cleaning brush pellet stove 40 x 1000 mm 059008 Adjustable plastic feet 20x20 complete 6 pieces 12 What is included Art No Equipment Qu...

Страница 44: ...Clou Pellet Clou Compact Pellet User instruction 42 English 13 Data processing...

Страница 45: ...ey diameter _____Chimney height ______ Sea level Chimney flue Approved by chimney sweep yes no Chimney flue draught Actual value _______ Target value _____ 3 12 Pa Controlled living space ventilation...

Страница 46: ...of actual condi tion hybrid stove installation Please be sure to obtain the customer s consent before hand wire brush glove user instructions Start combustion and burnout phases car ried out The end...

Страница 47: ...Clou Pellet Clou Compact Pellet User instruction 45 English 15 Service Report...

Страница 48: ...Clou Pellet Clou Compact Pellet User instruction 46 English AUSTROFLAMM GMBH Austroflamm Platz 1 A 4631 Krenglbach Tel 43 0 7249 46 443 www austroflamm com info austroflamm com 940302 Stand 11 2022...