Alarms and error messages
ALARMS are displayed in yellow on the control panel. If an alarm is displayed, your pellet stove may still be
used. See section 5.1 Resetting alarms & error messages.
Alarm code
Description
Solution
Alarm
–
A001
Fuel level low
Refill pellets, then the alarm must be cleared by
briefly pressing the "reset button" several times.
See section "Fuel level indicator"
Alarm - A002
Service is due
A maintenance-free period of approximately 1,700
operating hours is specified for the stove. After this
period has elapsed, the stove signals via ALARM
that a service is due.
Maintenance of the stove must be carried out by an
authorised Austroflamm service engineer or by
Austroflamm.
Alarm - A004
Battery is empty
The storage battery (model CR2032) of the control
unit is weak and must be replaced.
The battery should be replaced every 2 years as
part of a service. Section 6 shows you how to re-
place the battery.
Alarm - A006
Hopper lid is open
If the hopper lid remains open for more than 60
seconds, the stove will stop and display this alarm.
Close the hopper lid. The stove is then ready to
start up again. If the alarm is still displayed, call
your Austroflamm service engineer.
Содержание Clou Compact Pellet
Страница 2: ......
Страница 3: ...Clou Pellet Clou Compact Pellet User instruction 1 English...
Страница 5: ...Clou Pellet Clou Compact Pellet User instruction 3 English 14 Start up log 43 15 Service Report 45...
Страница 18: ...Clou Pellet Clou Compact Pellet User instruction 16 English Function diagram...
Страница 29: ...Clou Pellet Clou Compact Pellet User instruction 27 English Models with an ON OFF feeder motor...
Страница 44: ...Clou Pellet Clou Compact Pellet User instruction 42 English 13 Data processing...
Страница 47: ...Clou Pellet Clou Compact Pellet User instruction 45 English 15 Service Report...