![austriamicrosystems AS5046 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/austriamicrosystems/as5046/as5046_operation-manual_3019965009.webp)
AS5046 12-BIT PROGRAMMABLE MAGNETIC ROTARY ENCODER
Demoboard Operation Manual
Revision 1.1, 3-Jun-08 www.austriamicrosystems.com
Page 9 of 21
3.3.3
Analog Mode Tab
Five bits of the OTP are used to configure the AS5046 analog output modes. (For more details please refer to the data
sheet)
Analog Output Range:
The Angular Range selector allows a digital pre-selection of the angular range. The AS5046 can be configured for
a full scale angular range of 45°, 90°, 180° or 360°.
OR1 OR0 Mode
Note
0 0
360° Angular Range
default mode
analog resolution= 10bit (4096 steps) over 360°
0 1
180° Angular Range
analog resolution= 10bit (4096 steps) over 180°
1 0
90° Angular Range
analog resolution= 10bit (4096 steps) over 90°
1 1
45° Angular Range
analog resolution= 9 bit (512 steps) over 45°
Clamped Mode:
Depending on the application, the analog output can be set as rail-to-rail output or as clamped output with 10%-90% of
½ * VDD5V (pin16) or DACref (pin9).
ClampMdEN
Output
Note
0
0% - 100%
default mode; internal DACreference
1
10% - 90%
External DAC reference
Note: The output is also related to the RefExtEN OTP bit.