ZONEMIX
INSTALLATION AND OPERATION MANUAL
22
ACCESSORY WIRING GUIDE
australianmonitor.com.au
Use any port to any zone/s
Yes
Use one accessory port per zone.
i.e. Port 1 to Zone 1, Port 2 to Zone
2 etc. As audio inputs require their
own home run.
STEP 1: DECIDE PORT WIRING LAYOUT
STEP 2: CONFIRM YOU DO NOT EXCEED THE FOLLOWING LIMITS
Maximum cable length per port
Accessories per port Maximum Accessories in system
130m
8
150m
7
170m
6
200m
5
250m
4
350m
3
500m
2
The maximum distances quoted in the table are due to DC current limitations.
The paging stations and wall panels can be locally powered to increase the cable length to a maximum
of 500m. Please read the following additional document:
Advanced accessory port wiring guide.
Do you need local
audio inputs?
2
Only one audio input can be
used per port.
Wall controllers and paging
stations can go on any port.
No
24