ZONEMIX
INSTALLATION AND OPERATION MANUAL
20
Accessory LED States
CONNECTING WALL PANEL AUDIO INPUTS
FRONT PANEL
The ZONEMIX accessory ports each have a single balanced audio input for use with a remote audio wall panel. This input is referred to
as the LOCAL input.
Each accessory ports LOCAL input is locked to the corresponding output zone. E.g. Accessory Port 1 is the Local input for Zone 1
Connect any balanced audio source to the accessory port.
Compatible wall panels include,
• WPBT – Bluetooth audio receiver
• WPML – MIC/Line active audio input
• WPXLR – passive XLR audio input
Important: Only 1 audio input wall panel is supported per zone
Referring to the wiring guide section, the accessory port wiring for the LOCAL input is,
• Pin 5 GND
• Pin 7 Local Input +
• Pin 8 Local Input -
The WPBT must be paired to the ZONEMIX system which then instructs the wall panel to transmit mono audio out. If it is not paired it
will transmit stereo out and you will only hear the left channel in the local input.
The front panel allows the control of various features in the ZONEMIX. However, these can be disabled if you wish to prevent end users
from modifying the setup.
• Disable input volume level control
• Disable output volume level control
• Disable preset recall/saving
• Disable Audio Setup menu access
• Disable System Setup menu access
• Disable entire front panel.
(Shows device name and display locked message)
CONNECTING WALL PANEL CONTROLLERS CONT.
LED Status
Meaning
Resolution
All LEDs on, once a second
Not Paired
Put accessory into pairing mode
All LEDs on every 0.2 seconds
Pairing Mode
Pair accessory with ZONEMIX using the PC control
software
LED chase anti clockwise, one led
on at a time (led changes every 0.5
seconds)
Erasing firmware to prepare for
new firmware
Wait until the accessory has finished erasing
LED chase clockwise, one led on
at a time (led changes every 0.5
seconds)
Writing new firmware
Wair until the ZONEMIX has finished writing firmware
to the accessory
Alternate left, right LEDs every
500ms
Identify Mode
Press any button to cancel identify mode
Top left LED on once a second
Needs firmware download
Download new firmware to the accessory by pairing it
to the system
All RED LEDs on
Master Override, Evac, Alert,
Intruder Active (Wall panel disabled)
Wait until the master override has finished
Top left LED on (led change state
every 2 seconds)
Fault
Return to service