AUSTRALIAN MONITOR 9323383020634 Скачать руководство пользователя страница 2

IMPORTANT SAFETY INFORMATION

PRÉCAUTIONS DURANT UTILISATION

1.  READ these instructions.
2.  Keep these instructions.
3.  Heed all warnings.
4.  Follow all instructions.
5.  Do not use this apparatus near water.
6.  Clean only with dry cloth.
7.  Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8.  Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9.  Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. 

A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety.  
If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10.  Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit  

from the apparatus.

11.  Only use attachments/accessories specified by the manufacturer.
12.  Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used,  

use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13.  Unplug this apparatus during lightning storms or when unused for long periods of time.
14.  Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as  

power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been  
exposed to rain or moisture, does not operate normally, or has been dropped.

15.  This appliance shall not be exposed to dripping or splashing water and that no object filled with liquid such as vases shall be placed on the apparatus.
16.  Plug this apparatus to the proper wall outlet and make the plug to be disconnected readily operable.
17.  Mains plug is used as disconnected device and it should remain readily operable during intended use. In order to disconnect the apparatus from 

the mains completely, the mains plug should be disconnected from the mains socket outlet completely.

18.  WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
19.  An appliance with a protective earth terminal should be connected to a mains outlet with a protective earth connection.
20.  The apparatus should be disconnected from the mains completely before speaker wiring. The speaker output should be proper protected from 

direct contact and pay attention to speaker connections, terminals and speaker wiring during normal operation.

1.  LISEZ ces instructions.
2.  Tenez ces instructions.
3.  Notez tous les avertissements.
4.  Suivez toutes les avertissements.
5.  N’utilisez pas ce produit près de l’eau (la piscine, la plage, le lac, etc.).
6.  Nettoyez seulement avec une étoffe sèche.
7.  Ne bloquez aucuns troux de ventilation. Installez en accord avec les instructions du manufacturier.
8.  N’installez près aucunes sources de chaleur comme radiateurs, registres de chaleur, fours ou les autres équipements (y compris amplificateurs) qui 

produisent la chaleur.

9.  Ne défaites pas le but de sécurité de la fiche polarisée ou base-type. Une fiche polarisée a deux tranchants avec un plus large que l’autre. Une 

fiche de base type a deux a deux tranchants et une troisième pointe de base, le tranchant large ou la troisième pointe est fourni pour votre sécurité. 
Si la fiche donnée ne conforme pas votre prise de contact, consultez un électricien pour remplacement de la prise de contact obsolète.

10.  Protegez le cordon de secteur contre être marchée dessus ou pincez en particulier aux fiches, aux douilles de convenance, et au point où ils sort-

ent de l’appareil.

11.  Seulement utilisez attachements/accessoires spécifiés par le manufacturier.
12.  Utilisez seulement avec un chariot, un stand, un trépied, un support ou une table indiquée par le manufacturier, ou vendue avec l’appareil. Quand 

un chariot est utilisé, faites attention en déplaçant la combinaison d’appareil/chariot pour éviter de se déséquilibrer.

13.  Arrachez la fiche du dispositif durant éclair et orage ou quand pas utilisé pour longues périodes de temps.
14.  Référez au personnel qualifié de service pour toutes réparations. La réparation est donnée quand le système a été endommagé à n’importe façon, 

par exemple un fil ou une fiche endommagé(e) de la source d’alimentation. Avoir été exposé à pluie ou humidité, n’opère pas normalement, ou 
avoir été tombé.

15.  L’appareil ne doit pas être exposé aux écoulements ou aux éclaboussures et aucun objet ne contenant de liquide, tel qu’un vase, ne doit être placé 

sur l’objet.

16.  Branchez l’appareil à une source appropriée et faire que la prise à débrancher soit facilement accessible.
17.  La prise du secteur ne doit pas être obstruée ou doit être facilement accessible pendant son utilisation. Pour être complètement déconnecté de 

l’alimentation d’entrée, la prise doit être débranchée du secteur.

18.  AVERTISSEMENT: Pour éviter le risque d’incendie ou de chocs électriques, ne pas exposer cet appareil à la pluie ou à l’humidité.
19.  Un appareil avec la borne de terre de protection doit être connecté au secteur avec la connexiion de terre de protection.
20.  Assurez-vous que l’appareil est hors tension avant de connecter les hauts parleurs. Verifiez que la sortie des enceintes soit protégées contre un contact 

physique. Respecter les polarités des terminaux ainsi que le câblage des enceintes pendant le fonctionnement afin d’assurer une utilisation sécurisee.

Содержание 9323383020634

Страница 1: ...INSTALLATION AND OPERATION MANUAL ZONEMIX MIXERS ZONEMIX4 ZONEMIX 8 ...

Страница 2: ...1 LISEZ ces instructions 2 Tenez ces instructions 3 Notez tous les avertissements 4 Suivez toutes les avertissements 5 N utilisez pas ce produit près de l eau la piscine la plage le lac etc 6 Nettoyez seulement avec une étoffe sèche 7 Ne bloquez aucuns troux de ventilation Installez en accord avec les instructions du manufacturier 8 N installez près aucunes sources de chaleur comme radiateurs regi...

Страница 3: ...E PERSONNEL The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance For European Union countries This symbol on the product or its packaging indicates that this product must not be disposed of with other waste Instead it is your responsibility to dis...

Страница 4: ... or WPXLR wall panels ZONEMIX PC control software free via download Mic Line 1 Mic Line 2 Line 3 Line 4 Line 5 Line 6 Local Input 1 8 Paging Input CPU DSP INPUT MIX MASTER INPUT STAGE Paging Chime Tone Message Scheduler Pink Sine ZONE OUTPUT ZONE 2 ZONE 1 LEFT ZONE 1 ZONE 1 RIGHT ZONE 3 ZONE 2 RIGHT ZONE 4 ZONE 2 LEFT ZONE 5 ZONE 3 RIGHT ZONE 6 ZONE 3 LEFT ZONE 7 ZONE 4 RIGHT ZONE 8 ZONE 4 LEFT ZO...

Страница 5: ...E KNOB Rotate left and right to select the output zone Pushing the knob will enter Audio Setup mode Consult page 9 for more details MIX KNOB Rotate left and right to select the desired input channel mix for the output zone Pushing the knob will enter System Setup mode Consult page 9 for more details LCD CHARACTER DISPLAY 20x2 blue LCD character display PRESETS KNOB Rotate left and right to cycle t...

Страница 6: ... XLR balanced socket is provided on each microphone input Pin 1 Signal Ground Pin 2 Hot non inverting or in phase Pin 3 Cold inverting or reverse phase MIC GAIN Provides a rear panel input gain adjustment for Inputs 1 and 2 1 2 3 4 5 GENERAL PURPOSE INPUTS AND OUTPUTS Configurable in the PC control software to perform various actions See page 15 for further details TONE GENERATOR Connect any of th...

Страница 7: ...y high quality twin core shielded cable should be used Pin 1 Signal Ground Pin 2 Hot non inverting or in phase Pin 3 Cold inverting or reverse phase When wiring from an unbalanced source you must ensure that pin 3 is connected to pin 1 input ground either by linking the pins in the input connector or by the source equipment s output wiring When wiring for an unbalanced source Pin 1 Signal Ground P...

Страница 8: ...ls PAGING TONE GENERATOR MESSAGE PLAYER The paging tone generator and message player have independent volume controls that bypass the zone master and directly feed to the zone output Each volume control should be set to the appropriate level required for the zone PAGING STATIONS Firstly set the Paging input level to 20dB for the output zone being used Next perform a loud page by speaking closely t...

Страница 9: ...t until the short is released 4 BELL a short repeating tone burst with decay and reverb Triggered by shorting BELL to GND the sound will continue to repeat until the short is released 5 CHIME a four note increasing tone suitable for paging preannounce Triggered by shorting CHIME to GND it will sound only once each time the trigger is activated Please note CHIME tone must play to completion before ...

Страница 10: ...matting of SD cards larger than 32GB to FAT32 You must use third party applications to format SD cards larger than 32GB to the required FAT32 format PC CONTROL SOFTWARE The ZONEMIX comes with a free PC application to allow advanced configuration and control of the system The software can be downloaded from www australianmonitor com au and can be accessed from either the USB or Ethernet connection ...

Страница 11: ...d Internet Network and Sharing Center 2 Click Change adapter settings 3 Right click on Local Area Connection that the ZONEMIX is connected to Click Properties 4 Make sure IPv4 is enabled and select Internet Protocol Version 4 TCP IPv4 Click Properties 5 Select Use the following IP address 6 Enter the following as per the screenshot below a IP address 192 168 1 1 b Subnet mask 255 255 255 0 c Defau...

Страница 12: ...nd minimum volume levels using the Advanced tab Section 2a accessed by selecting the outputs tab Adjust the post zone master volume audio mix for paging paging chime and message levels Pink Noise and sine waves can also be activated for use during system commissioning Section 3 Mic or Line setting for Inputs 1 and 2 and stereo mode ZONEMIX4 only Apply high pass filters and turn on phantom power Ap...

Страница 13: ...ls to 96dB To MIX lower priority inputs at a reduced volume set Duck Depth level in the Modify Priority Levels to a value between 96dB and 0dB If two inputs are the SAME priority level they will MIX together and MUTE or DUCK lower priority inputs depending on the priority level set CONTROL SECTION PRIORITY CONTROL MASTER OVERRIDE The ZONEMIX has an advanced priority scheme which can be customised ...

Страница 14: ...hreshold This allows for delay to be added if required up to 25 seconds Duck Depth sets the level lower priority inputs are set to during a priority event Set it to 96dB to mute the input or a value lower than 0dB to mix the audio at a lower level The Tones Messages Scheduler Message GPI Message Bell and Chime all share one audio channel from the CPU DSP This means only one can be active at a time...

Страница 15: ... GENERAL PURPOSE INPUTS AND OUTPUTS The ZONEMIX4 and ZONEMIX8 have 4 inputs and outputs and 8 inputs and outputs respectively Use the PC control software to configure the I O Use the dropdown menus to select the desired function for the input or output INPUTS Enable Master Override Mute Zone s Master Recall a preset Trigger a message from the SD card OUTPUTS Scheduler controlled Paging Active Wall...

Страница 16: ...ress any button on the paging station during pairing to cancel the pairing mode Only have one wall panel or ZMPS in pairing mode at a time In the Zonemix PC control software 1 Select the Pagers button in the main window 2 Select any unused Pager tab 3 Select the Pair button 4 The Zonemix4 8 will upload the latest firmware to the ZMPS Note this will take approx 30 seconds The LEDs will rotate anti ...

Страница 17: ...t 2 Select the message to be played from the file explorer window Note You must have an SD card installed with WAV audio files available 3 To playback the pre recorded message select the zone s and then press the assigned message button PRE RECORDED MESSAGE PLAYBACK To playback a pre recorded message select the zone s that the message should be sent to and press the assigned message button Note Yo...

Страница 18: ... the system it can be disconnected in the PC control software Go to the appropriate paging station tab See the Identify section above if you do not know which station to select Select the Disconnect button In order to re connect the ZMPS follow the pairing instructions section of this manual Note You can customize the pre announcement chime of the paging stations See the SD card section for detail...

Страница 19: ...very 0 2s Press any button on the wall panel during pairing to cancel the pairing mode Only have one wall panel or ZMPS in pairing mode at a time In the Zonemix PC software 1 Select the Wall Panels button in the main window 2 Select any unused wall panel tab 3 Select the Pair button 4 The Zonemix4 8 will upload any firmware updates to the wall panel The LEDs will rotate anti clockwise indicating s...

Страница 20: ...abled if you wish to prevent end users from modifying the setup Disable input volume level control Disable output volume level control Disable preset recall saving Disable Audio Setup menu access Disable System Setup menu access Disable entire front panel Shows device name and display locked message CONNECTING WALL PANEL CONTROLLERS CONT LED Status Meaning Resolution All LEDs on once a second Not ...

Страница 21: ...the corresponding output zone and only one can be used per zone E g Accessory port 1 local input connects to Zone 1 However multiple wall panels and paging stations can be connected on the same accessory port ZONEMIX 4 ZONEMIX 8 Wall Controllers Audio Sources Supports up to 8 controllers per port see page 2 for details Key Supports ONE audio input PER accessory port Supports up to 8 paging station...

Страница 22: ...ximum cable length per port Accessories per port Maximum Accessories in system 130m 8 150m 7 170m 6 200m 5 250m 4 350m 3 500m 2 The maximum distances quoted in the table are due to DC current limitations The paging stations and wall panels can be locally powered to increase the cable length to a maximum of 500m Please read the following additional document Advanced accessory port wiring guide Do y...

Страница 23: ...e and 6 cabling supported T 568B wiring recommended However T 568A also supported T 568B wiring 3 ZONEMIX AND ZMPS WIRING ZMPS DAISY CHAIN WIRING Pin Colour Signal 1 Orange White Paging Audio 2 Orange Paging Audio 3 Green White RS485 B 4 Blue 24V DC 5 Blue White GND 6 Green RS485 A 7 Brown White Remote Input 8 Brown Remote Input ZMPS Use an RJ45 splitter or terminal block if daisy chain wiring req...

Страница 24: ...ire the wall panels as per the images below Category 5 5e and 6 cabling supported T 568B wiring recommended However T 568A also supported STEP 3 ACCESSORY PORT WIRING CONT Unused if not daisy chaining Unused unless connecting to downstream ZMPS 1 2 3 4 5 6 7 8 Paging Audio Paging Audio RS485 A 24V DC GND RS485 B Remote Input Remote Input 4 T 568B wiring T 568B wiring ...

Страница 25: ...the ZONEMIX and Accessories based on which ports you use Terminate the LAST RS485 accessory on the port cable run Paging station termination Wall panel termination Terminate the ZONEMIX accessory ports as per the table using the PORT TERM switches 1 2 Examples BOTH Ports used PORT TERM OFF PORT TERM ON Terminate end points ONE port used 5 ONE PORT USED BOTH PORTS USED Port 1 OR Port 2 used Port 3 ...

Страница 26: ...4R and WP10 both have 3 general purpose outputs which can be controlled from the wall panel buttons to trigger external devices such as projectors 6 Internal Logic GPO1 GPO2 GPO3 Example Relay Connection 24V GND Each Output is an open collector transistor Maximum Voltage 48V Maximum Sink Current 250mA GPO Schematic VERSION 2 1 JULY 2022 ...

Страница 27: ... quickly Task Command Reply Set Zone Output 1 to 20dB set active out1 vol 20 0 reply active out1 vol 20 0 Set Zone 1 Input 1 to 0dB set active mixout1in1 vol 0 0 reply active mixout1in1 vol 0 0 Unmute Zone 1 Input 2 set active mixout1in2 mute false reply active mixout1in2 mute false Recall preset 1 set device preset recall 1 reply device preset recall 1 Increment Zone8 Input 6 up 3dB set active mi...

Страница 28: ...ETUP menu The following settings can be changed RESET NETWORK CONFIGURATION This will reset to the following defaults DHCP Mode True DHCP Default IP 192 168 1 10 RESET ADMIN ACCOUNT LOGIN The account login settings will all be restored to to the following defaults Username admin Password admin RESET ALL SETTINGS TO FACTORY DEFAULT The network configuration user account data and audio settings will...

Страница 29: ...ZONEMIX INSTALLATION AND OPERATION MANUAL 29 DIMENSIONS 484 25 44 5 437 25 43 5 175 5 43 5 44 5 ...

Страница 30: ...FREQUENCY RESPONSE 20Hz 20kHz 0 5dB THD 0 01 20Hz 20kHz 20kHz BW Unity Gain SNR 100dBA Max Output 1kHz 20kHz BW A Weighted miniDSP Volume control Matrix Mixer High Low pass filters Tone Control 100Hz 10dB 10kHz 10dB Compressor Limiter Delay up to 50m 150ms ZONEMIX4 Only Sine Wave Generator 500 1k 5k and 10kHz Internal Pink Noise Generator CONTROL USER CONTROLS Front Panel Wall Panels COMMS INTERFA...

Страница 31: ...BTU 1W 3 412 BTU Hr 24V OUT 100mA Total from both outputs DC INPUT SOCKET 100mA Total from both outputs MECHANICAL SHIPPING DIMENSIONS 484 x 160 x 44 5mm 19 0 W x 6 3 D x 1 7 H PRODUCT DIMENSIONS with rack ears 484 x 176 x 44 5mm 19 0 W x 6 9 D x 1 7 H Including Knobs and Rear Connectors PRODUCT DIMENSIONS without rack ears 484 x 176 x 44 5mm 19 0 W x 6 9 D x 1 7 H Including Knobs and Rear Connect...

Страница 32: ...D BY AUSTRALIAN MONITOR Address Unit 1 2 Daydream Street Warriewood NSW 2102 Australia Website www australianmonitor com au International enquiries email international australianmonitor com au ABN 86 003 231 187 ...