1. Make sure

2. Make sure the rack door is rigid and no bending.  

3. Don’t over tighten the 

fi

 xing screws.

Two ends of latch rod can entry into the top & bottom holes without stress.

The top & bottom holes with enough space tolerance.

1

2

Pay attention to the following points when install the lock system. 
Otherwise, it may cause handle distortion and malfunction.     

Lock hole

Lock hole

Rod

Rod

2-point lock holes
( top & bottom )

2-point lock holes
( top & bottom )

enough
tolerance

Rigid 
door

limited 
tolerance

Bending
door

Содержание InfraBox X-1000

Страница 1: ...www austin hughes com UM X 800 XMS 02 S Q420V1 User Manual Smartcard Access Control for Racks Designed and manufactured by Austin Hughes X 2000 X 1000 XMS 02 S InfraBox GUI SNMP X 800 Smartcard Handle ...

Страница 2: ...e personnel What the warranty does not cover Any product on which the serial number has been defaced modified or removed Damage deterioration or malfunction resulting from Accident misuse neglect fire water lightning or other acts of nature unauthorized product modification or failure to follow instructions supplied with the product Repair or attempted repair by anyone not authorized by us Any dam...

Страница 3: ...table and level or mounted into a suitable cabinet Make sure the place has good ventilation is out of direct sunlight away from sources of excessive dust dirt heat water moisture and vibration Position the equipment with respect to related facilities Before Installation InfraBox Installation Suggest the installation at the rear top mounting of cabinet M6 screws set not provided ...

Страница 4: ...00M P 8 1 5 Door Sensor Installation Inductive IR Mechanical P 19 Part 2 PDU 2 1 PDU P 26 Part 3 Environmental Sensor Peripherals 3 1 Temp Humid Sensor P 27 3 2 Smoke Sensor P 28 3 3 Shock Sensor P 29 3 4 Water Sensor P 30 3 5 LED Light Bar P 31 3 6 LED Beacon P 32 Part 4 XMS 02 S InfraBox GUI Software 4 1 Device Monitoring Setting P 33 4 2 System Setting P 43 4 3 SNMP P 44 ...

Страница 5: ...www austin hughes com UM X 800 XMS 02 S Q420V1 Intentionally Left Blank ...

Страница 6: ... to the handle Connect sensor peripheral to InfraBox Daisy Chain Star Mixed connection For each InfraBox ONE by ONE For front rear door connect cable to InfraBox PDU daisy chain setting Connect InfraBox by daisy chain via Cat5 6 cable InfraBox Cascade Prepare a notebook computer InfraBox installation Door sensor installation Configure IP setting Smartcard handle installation PDU installation Senso...

Страница 7: ... Card 12 Patented and Worldwide Patents Pending X 2000 OR X 1000 InfraBox 1 pc 800 MiFARE OR Proximity smart card handle pair Inductive OR Mechanical door sensor pair Front door cable 2 section with joint connector 1 pc 3150mm Rear door cable 2 section with joint connector 1 pc 2350mm 6 Power cord 1 pc Activated smartcard 1 pc Key 1 pc Cable clip 8 pcs X 2000 X 800P X 800M OR OR X 1000 Handle moun...

Страница 8: ...rt x 1 RJ 45 up to fan unit daisy chain level x 2 Water sensor port x 2 7 1 2 3 6 9 11 4 8 10 13 12 5 14 X 2000 X 1000 X 2000 Specification X 1000 1 2 3 5 4 7 6 8 12 10 14 13 11 9 Product Dimension W x D x H 400 x 135 x 39 7 mm 15 7 x 5 3 x 1 6 inch Packing Dimension W x D x H 557 x 367 x 98 mm 21 9 x 14 4 x 3 9 inch Net Gross Weight 1 06 kgs 2 3 lbs 2 2 kgs 4 8 lbs Power Consumption Auto sensing ...

Страница 9: ...Door Sensor InfraBox Daisy Chain Connection 1 3 5 2 4 InfraBox SmartCard handle Door sensor with 6 cable Door cable door section Door cable cabinet section Front Door Rear Door 2 2 2 2 3 4 3 4 5 5 1 Up to 50 Infrabox in a single daisy chain Up to 100 meters in a single daisy chain InfraBox X 2000 InfraBox X 1000 InfraBox X 2000 ...

Страница 10: ...ear top inside Smoke Sensor 1 rear inside top Flashing LED Beacon 1 front cabinet roof Temp Humid Sensor 2 any inside position Shock Sensor 1 upper inside Fan Unit 2 door mount or rackmount PDU 4 vertical or rackmount Water Sensor 1 surrounding cabinet on floor 1 3 6 2 4 8 7 5 2 4 7 1 6 5 8 3 Front Door Rear Door 1 3 InfraBox X 1000 X 2000 ...

Страница 11: ...nload the IP setup utilities from the link below http www austin hughes com support utilities infrasolutionX InfraBoxSetup msi 2 Double click the InfraBoxSetup msi and follow the instruction to complete the utilities installation 3 Power ON the InfraBox 4 Go to each InfraBox with the notebook computer a piece of CAT 5 6 cable to configure the InfraBox as below To notebook computer LAN port To Infr...

Страница 12: ... ONE BY ONE 5 Click Scan to search the connected InfraBox 6 Change the IP address Subnet mask Gateway then Click Save to confim the setting of InfraBox The default IP address is as below IP address 192 168 0 1 Subnet mask 255 255 255 0 Gateway 192 168 0 254 1 3 InfraBox X 1000 X 2000 IP Setup for InfraBox ...

Страница 13: ...mplicated door customization for the smartcard handle integration Universal Mounting Cut out Models of left right side opening X 800P X 800M support left side open If user requires right side open please order X 800P R X 800M R Model Left side open Right side open X 800P Proximity X 800M MiFARE X 800P R Proximity X 800M R MiFARE Back View Cut out Side View Close Side View Open Unit mm 1 4 Handle X...

Страница 14: ...customization for the cam is required Cam customization service upon your request please contact your sales representative 4 Insert the M5 x 15mm screw x 1 with circle hole washer to secure the Cam to the handle 5 Place the U bracket with M3 x 10mm screw x 2 to further secure the handle in place 1 3 7 2 5 6 4 Handle mounting screw set for single point lock Qty Single Point Lock Handle mounting bra...

Страница 15: ...ews Cam lock can slide into the hole without stress The cut out of the cam hole with enough space tolerance 1 2 Pay attention to the following points when install the lock system Otherwise it may cause handle distortion and malfunction Door cam lock Cam lock hole Cam lock hole enough tolerance Rigid door limited tolerance Bending door Door cam lock ...

Страница 16: ... and to fit the door top bottom locking position 4 Insert the M5 x 15mm screw x 1 with circle hole washer to secure the Rod latch to the handle 5 Place the U bracket with M3 x 10mm screw x 2 to further secure the handle in place 1 3 2 4 Rack door Rod latch 5 6 5 6 While insert the screws to secure the handle with electrical power screwdriver please set the torque NOT exceed 8 kgf cm Qty 2 Point Lo...

Страница 17: ... can entry into the top bottom holes without stress The top bottom holes with enough space tolerance 1 2 Pay attention to the following points when install the lock system Otherwise it may cause handle distortion and malfunction Lock hole Lock hole Rod Rod 2 point lock holes top bottom 2 point lock holes top bottom enough tolerance Rigid door limited tolerance Bending door ...

Страница 18: ...circle hole washer to secure the position 3 Insert Orignal handle screws x 2 through the Rod control system and door to the handle to fix it in place 4 Place the U bracket with M3 x 10mm screw x 2 to further secure the handle in place 4 4 5 6 Qty 2 Point Lock with rod control Handle mounting bracket 2 X M4 x 9mm screw for 4 X Square hole washer 6 X Circle hole washer w M5 x 15mm screw 2 U bracket ...

Страница 19: ... can entry into the top bottom holes without stress The top bottom holes with enough space tolerance 1 2 Pay attention to the following points when install the lock system Otherwise it may cause handle distortion and malfunction Lock hole Lock hole Rod Rod 2 point lock holes top bottom 2 point lock holes top bottom enough tolerance Rigid door limited tolerance Bending door ...

Страница 20: ...ocked Key cylinder to 9 o clock direction Under key lock mode even present the smartcard the handle still keeps locked Key unlock mode Key lock mode Under Smartcard mode always keep key cylinder to 12 o clock direction Important Note for Key lock Key cylinder to 3 o clock direction Key cylinder to 9 o clock direction Key unlock mode Key lock mode Unless the smartcard handle is defective lock unloc...

Страница 21: ...ance the maintenance key MK 001 is required to solve the problem Please insert the maintenance key to the cylinder with push force for turning it to normal direction 9 or 12 or 3 o clock Maintenance Key MK 001 Important Note for Handle For your own safety please return the handle to park position properly in case reckless collision 1 4 Handle X 800P X 800M ...

Страница 22: ...reen Unlocked status in flashing red Unauthorized door open If the door is opened improperly or by force handle LED will turn to red flashing with audio alarm beep sound To open the door within 10 seconds Door Opening improperly or by force NO Authenticated Smartcard Detection Within 10 seconds after smartcard detection users should lift up the handle open the door return the handle to park positi...

Страница 23: ...www austin hughes com UM X 800 XMS 02 S Q420V1 Intentionally Left Blank ...

Страница 24: ... mini size 32 5 x 12 2 x 9 2 mm Package content Inductive sensor w 2m cable x 2 2mm adhesive tape x 6 Mounting bracket x 2 9 2 mm 32 5 mm 12 2 mm 1 2 3 4 Sensor area Red LED light up while door opening 2m cable Cable jack connect to handle 2 3 4 1 adhesive tape cabinet frame made of iron sensing distance 3mm Requirement unit mm Ø6 5mm hole cutting required on door frame Mounting by bundled bracket...

Страница 25: ...ith adhesive tape or mounting bracket to ensure the sensing distance between door to frame within 3mm while door in close status Sensor Operation CLOSED Cabinet frame Door frame Sensing distance 3mm OPENED Sensing distance 3mm Cabinet frame Door frame DOOR CLOSE close door inductive sensor detects the cabinet frame DOOR CLOSE SIGNAL sends out DOOR OPEN open door inductive sensor lose detection wit...

Страница 26: ... Door Sensor pair S DIR Features Magnetic base for easy setup No custom cutting required on doors Light weight mini size 33 x 19 x 7 mm 2m cord Package content IR sensor w 2m cable x 2 reflective label x 2 opposite to the IR door sensor for a better response size 30 x 40 mm rack frame made of ferrous metal iron sensing distance door close 40mm door open 50mm Requirement ...

Страница 27: ...while door in close status stick the reflective label on the rack frame just opposite to the sensor position Sensor Operation CLOSED Rack frame Door frame Sensing distance 40 mm Reflective label Reflective label OPENED Sensing distance 50 mm Rack frame Door frame DOOR CLOSE close door IR sensor detects the rack frame DOOR CLOSE SIGNAL sends out DOOR OPEN open door IR sensor lose detection with rac...

Страница 28: ...iew Front View Top View unit mm Cable connector Press button total travel distance 9 25 mm min actuation distance 3 00 mm 2 1 2 1 6 5 15 0 15 75 2 11 7 3 9 25 25 0 15 11 3 Package content Ø6 5mm hole cutting required on door frame Mechanical sensor w 2m cable x 2 Mounting bracket x 2 Ø Mounting by custom cutout on door frame Mounting by bundled bracket Cutout size 23 x 12 5 mm ...

Страница 29: ...utton is released DOOR OPEN SIGNAL sends out CLOSED Cabinet frame Door frame Physical touch required OPENED Button released Cabinet frame Door frame Installation steps Suggested sensor position connect to the handle place the sensor at the top middle of the door install the sensor in the custom hole secure it with bundled mounting screws 6 32x4 5mm x 2 Actuation distance 3mm ...

Страница 30: ...c Color Black Connection Cable Length sensor w 2m cable Environmental Operating 20 to 60 C Degree Storage 20 to 60 C Degree 30 to 70 C Degree Relative Humidity 5 90 non condensing Dimensions Product 32 5L x 12 2W x 9 2H mm 52W x 22 5L mm with metal plate Packing Weight Net Gross 6g 14g with metal plate Supply includes 1 Inductive door sensor with 2m cable Mechanical door sensor 2 2mm Adhesive tape...

Страница 31: ...cable Up to 20M Cat 5 6 cable Up to 20M Cat 5 6 cable Up to 20M Step 1 Press the button to display no 9 and press to confirm Step 2 Press the button to PDU ID and press to confirm Step 3 In display 9 1 Press the button to select PDU level no 1 4 and press to confirm Step 4 Press to exit PDU level setting Under an InfraSolution X network each InfraBox X 2000 series ONLY supports InfraPower intellig...

Страница 32: ...on Cable Length TH sensor w 2m cable standard TH sensor w 4m cable option T sensor w 2m cable standard T sensor w 4m cable option Cable Specification 4 wired 3 5mm to RJ11 Cable Color Black Beige Environmental Operating 0 to 80 C Degree Storage 5 to 80 C Degree Humidity 0 100 non condensing Dimensions Product 30L x 25W x 18H mm Weight Net 66g Supply includes 1 TH Sensor Temperature Sensor 2 4 wire...

Страница 33: ...s Housing Chassis Cover ABS plastic Color Ivory White Connection Cable Length 1m 3m option Environmental Operating 5 to 50 C Degree Storage 10 to 60 C Degree Humidity 5 90 non condensing Dimensions Product 103L x 103W x 55H mm Weight Net 165g Supply includes 1 Smoke Sensor with 1m cable Compatibility InfraSolution X 2000 series InfraGuard EC 300M EC 300 Safety Regulatory FCC CE certified Environme...

Страница 34: ...Power consumption 0 18 Watt Housing Chassis Cover ABS plastic Color White Connection Cable Length 1m 3m option Environmental Operating 5 to 55 C Degree Storage 10 to 60 C Degree Humidity 5 90 non condensing Dimensions Product 26 x 85 x 24 mm Weight Net 40g Supply includes 1 Shock Sensor with 1m cable Compatibility InfraSolution X 2000 series InfraGuard EC 300M EC 300 Safety Regulatory FCC CE certi...

Страница 35: ...Power consumption 125 mWatt Connection Extension cable length 3m non detection Environmental Operating 20 to 60 C Degree Storage 20 to 80 C Degree Weight Net 450g Sensor extension cable Supply includes 1 Rope water sensor 2 Extension cable Compatibility InfraSolution X 2000 series InfraGuard EC 300M EC 300 Safety Regulatory FCC CE certified Environmental RoHS2 REACH compliant by SGS 3 4 Water Sens...

Страница 36: ...r Acrylic with milky white Installation Magnetic base for unrestricted installation Connection Cable Length 2m 3m option Environmental Operating 20 to 50 C Degree Storage 20 to 60 C Degree Relative Humidity 5 90 non condensing Dimensions Product 300L x 20W x 12H mm Weight Net 84g Compatibility InfraSolution X 2000 series InfraGuard EC 300M EC 300 Safety Regulatory FCC CE certified Environmental Ro...

Страница 37: ...er Len Polycarbonate Color Blue Connection Cable Length 1m 3m Environmental Operating 20 to 50 C Degree Storage 20 to 60 C Degree Relative Humidity 5 90 non condensing Dimensions Product 72L x 72W x 45H mm Weight Net 50g Supply includes 1 LED Beacon with 1m cable Compatibility InfraSolution X 2000 series InfraGuard EC 300M EC 300 Safety Regulatory FCC CE certified Environmental RoHS2 REACH complia...

Страница 38: ...ts only one InfraBox If you install more InfraBoxes multi windows will be required XMS 02 S is a management software with very limited features You can use more advanced software InfraSolution X Manager X ISM InfraBox X 1000 series ONLY provides an overview on the status of doors 1 Open Internet Explorer I E version 10 0 or above 2 Enter the configured InfraBox IP address into the I E address bar ...

Страница 39: ... and Low alert amp of PDU circuits Click Apply to finish the above settings Click Reset to rest peak amp or kWh of PDU circuit Click ON OFF to switch On Off outlet Switched PDU only View On Off status of outlets View aggregated current on the PDU View latest loading energy consumption of outlets Outlet measurement PDU only View the latest T TH reading connected to the PDU ...

Страница 40: ...Setting you can Change the Name of PDU outlet Change the Power up sequence delay of PDU outlet Switched PDU only Change Alarm amp R alert amp L alert amp of PDU outlet Outlet measurement PDU only Click Apply to finish Click Reset to reset peak amp kWh of PDU outlet Outlet measurement PDU only ...

Страница 41: ... XMS 02 S Q420V1 P 36 4 1 Device Monitoring Setting In TH details you can Activate Deactivate the TH sensors of PDU Change Location of TH sensors of PDU Change Alarm Setting R Alert Setting of TH sensors of PDU Click Apply to finish ...

Страница 42: ...www austin hughes com UM X 800 XMS 02 S Q420V1 P 37 4 1 Device Monitoring Setting In Access Control you can View the handle model View edit the Rack ID Zone Click Apply to finish ...

Страница 43: ... The door status The door last opened time The door last closed time The duration of the door being opened In Card Access you can view The last smartcard no open the door The last door unlock time by smartcard In Remote Unlock you can Open the door by remote View the last remote unlock time of the door ...

Страница 44: ...gn edit or delete user card Card Assignment 1 Direct input the last 8 digits of the card number to the field Card Edition 1 Direct change the existing card numbers in the field Card delete 1 Direct remove the existing card numbers from the field one by one Click Apply to finish the above configuration of smartcard ...

Страница 45: ...ow 3 Click Save and the file will be saved to the C Users user Downloads with the name export_handle txt Steps for Import 1 Select the InfraBox which you want to import handle configuration file 2 Connect the InfraBox to the notebook computer via a Cat 5 6 LAN cable 3 Login the WEB GUI of the InfraBox 4 Untick Auto data refresh 5 Click Import select the file to import then Click Open 6 After impor...

Страница 46: ...XMS 02 S Q420V1 P 41 4 1 Device Monitoring Setting In Setup you can Enable disable T TH sensor Smoke Shock sensor PDU Change Alarm Level of T TH sensor Change Lamp to Disable Always ON or Turn on when door open Click Apply to finish ...

Страница 47: ...System Setting In Audio and Visual Output Setting you can Enable Disable the Buzzer Beacon Alarm out output when the sensor event is triggered In Admin you can Change the IP address Subnet mask Gateway of the InfraBox Change the temperature unit displayed in the GUI Click Apply to finish ...

Страница 48: ...oad the InfraBox firmware from the link http www austin hughes com support software infrasolutionX XD280S img http www austin hughes com support software infrasolutionX XD180S img 2 Open Internet Explorer I E version 10 0 or above 3 Click Browse and select the firmware file xxx img from the specific path in the pop up window and Click Open 4 Click Upgrade to start the upgrade process It takes a fe...

Страница 49: ...http www austin hughes com support utilities infrasolutionX X 1000 zip X 1000 series To enable the SNMP support please take the following steps 1 Connect the InfraBox to a computer Refer to P 7 2 Open Internet Explorer I E version 10 0 or above 3 Enter the configured IP address into the I E address bar Default IP address is 192 168 0 1 4 Enter Login name Password Default login name password is 000...

Страница 50: ...germent 7 Click Enable in SNMP agent to start the SNMP agent service 8 Input Read community Default is public 9 Input Write community Default is private 10 Select disabled or V2Trap In SNMP Traps If select V2Trap please input the IP address of the SNMP Management station in Station IP 11 Click Apply to finish ...

Страница 51: ...www austin hughes com UM X 800 XMS 02 S Q420V1 Intentionally Left Blank ...

Страница 52: ...odify product specifications without prior notice and assumes no responsibility for any error which may appear in this publication All brand names logo and registered trademarks are properties of their respective owners Copyright 2020 Austin Hughes Electronics Ltd All rights reserved ...