background image

Aussie Eco-Clean Super Indy Operating & Maintenance Manual - 

2020

CLASSIFICATION

The user must observe the conditions of use of the applian-

ce prescribed by the Rules, and particularly he must respect 

the following classification:

As  for  the  protection  against  electric  shock,  the  H.P.cleaner 

belongs to CLASS I.

The H.P. cleaner is factory set  and all its safety devices are 

sealed. 

It is forbidden to alter their adjustment values.

The water in this machine is heated by a diesel fueled burner.

The  H.P.  cleaner  must  be  always  used    on  a  firm    and  flat 

ground, furthermore it must not be moved while it is working or 

connected to the electric supply.

Failure to observe this prescription may cause danger for the 

user.

The H.P. cleaner must not be used in the presence of corrosive 

or potentially explosive atmospheres. (vapours or gas).

The electrical installation  must be performed by qualified tech

-

nicians who are  able to work in observance of the governing 

rules  (in  compliance  with  the  provisions  of  the  IEC  60364-1 

standard) and of the manufacturer’s instructions.

Any  damage  to  persons  or  property  as  a  result  of  incorrect 

electrical installation is not the responsiblity of the manufac-

turer.

Machines under 3kW are fitted with a plug. Check the data plate 

on the machine and ensure that the power source is suitably 

rated and earthed. If an alternative plug needs to be fitted use 

a qualified electrician.

Do not use extensions to feed the H.P. cleaner.

The electric safety of this machine may be assured only when it 

is properly connected to an efficient grounding system in accor

-

dance with the governing laws for electric safety. (in compliance 

with the provisions of the IEC 60364-1 standard).

It is necessary to check this essential safety requisite. In case 

of doubt,  ask  for  accurate  control  of  the  power  system  by 

qualified personnel.

The manufacturer may not be considered responsible for dama-

ges occurred because of the lack of the grounding system.

The H.P. cleaner must be connected to the electric supply by 

means of an omnipolar switch with opening contacts of at least  

3 mm. This switch must have electric features which are consi-

stent with the appliance. (This requisite does not apply to H.P. 

cleaners with plug and electric power lower than 3 kW).

The appliance is disconnected from the electric supply only by 

pulling out the plug or switching off the omnipolar switch.

Failure to respect the above absolves the manufacturer of all 

liability and represents negligent use of the product.

The water cleaner is considered as a fixed device.

Water cleaners with the “Total Stop” device should be con-

sidered as off when the omnipolar switch is in the “O” position 

or the plug is unplugged from the socket.

The most important instructions 

are marked with the symbol:

  

INTRODUCTION

     

This manual must be read before installing, setting up and 

using the cleaner.  The manual is an integral part of the product.  

It is composed of two parts, one of which is yellow.

Read the warnings and instructions in this manual carefully as 

they provide important indications as to 

SAFETY IN USE and 

MAINTENANCE

, paying special attention to the general rules 

for safety listed in the yellow booklet.

KEEP  THIS  MANUAL  CAREFULLY  FOR  FUTURE  CON-

SULTATION.

 

The contents of this booklet must be brought to the attention 

of persons using or carrying out routine maintenance on this 

water cleaner.

!

!

!

!

|     

7

Содержание Eco Clean Super Indy

Страница 1: ...Aussie Eco Clean Super Indy High Pressure Washer Operating Maintenance Instructions Read all instructions carefully BEFORE using your Super Indy steam cleaner AUSTRALIAN PUMP INDUSTRIES ...

Страница 2: ... a specific unwanted event and the potential consequences if it should occur RISK RANKING TABLE The consequences loss outcomes are combined with the likelihood of those outcomes in the risk ranking table to identify the risk rank of each loss event e g a consequence of Moderate with a likelihood of Likely yields a risk rank of 17 The table yields a risk rank from 1 to 25 for each set of probabilit...

Страница 3: ...sticker Disconnect from power before servicing machine Burns from steam or hot water Personal injury 14 Warning in Operating Instructions decals on machine Unsecured machine moves unattended Cause of accidents and or injury 8 Use of chocks behind wheels or ute mounting kit Dislodged particles in atmosphere Sight damage 20 Never clean asbestos with high pressure water Use of eye protection Slipping...

Страница 4: ... Preparation 5 Description of symbols 6 Introduction 7 Intended use 8 Preliminary operations 8 General warnings for installation use 10 Use advice on using detergents 12 Maintenance 12 Periods of inactivity 14 Scrapping 14 Trouble shooting 15 Technical data 17 Notes 18 Routine Check Lists 20 ...

Страница 5: ...teed against faults in manufacture for one year from purchase Keep your receipt as proof of purchase This guarantee is invalid if the product is found to have been abused in any way or not used for the purpose for which it was intended Routine maintenance is the owner s responsibility Failure to maintain the machine in line with the services outlined on Page 8 will invalidate warranty Where possib...

Страница 6: ... THE BURNER ADJUSTING THE WATER TEMPERATURE FUEL DIESEL CHEMICHALS DETERGENT ANTI SCALE PRODUCT DO NOT DIRECT THE JET AT PEOPLE ANIMALS POWER SOCKETS OR THE MACHINE ITSELF ATTENTION RISK OF BURNS ATTENTION RISK OF ELECTRIC SHOCK EARTH WATER INPUT WATER OUTPUT DESCRIPTION OF SYMBOLS ON THE CLEANER 6 ...

Страница 7: ... with the governing laws for electric safety in compliance with the provisions of the IEC 60364 1 standard It is necessary to check this essential safety requisite In case of doubt ask for accurate control of the power system by qualified personnel The manufacturer may not be considered responsible for dama ges occurred because of the lack of the grounding system The H P cleaner must be connected ...

Страница 8: ...nd potentially dangerous INTENDED USE This appliance is intended exclusively for cleaning machines vehicles buildings and general surfaces suitable for treatment with a high pressure jet of detergent solution between 25 and 250 bar 360 3600 PSI This appliance has been designed for use with the detergents supplied or recommended by the manufacturer The use of other detergents or chemicals may influ...

Страница 9: ...ial to know the function of the cleaner s command and control devices FIG 2 FIG 6 FIG 5 WATER CIRCUIT CONNEC TION Connect the feed hose to the mains fig 5A and to the hosetail on the cleaner fig 5B Check that the pressure and quantity of the water supplied by the mains are sufficient for the cleaner to work properly 2 to 8 BAR 29 to 116 PSI Maximum temperature of fee ding water 50 C 122 F Connect ...

Страница 10: ...he applian ce disconnecting it from the water main and from the electricity main via the omnipolar switch or by unplugging the plug in the case of water cleaners rated at less than 3 kW without tampe ring with it Apply to one of our technical service centres The use of any electric appliance requires the respect of some basic rules Do not touch the appliance with wet or damp hands or feet Do not u...

Страница 11: ... water cleaner causes serious dam age to pump gaskets FIG 7 FIG 8 USING THE CLEANER CONTROL PANEL A On off switch B Temperature regulator C Detergent control tap if available D Pressure gauge STARTING THE CLEANER 1 Turn on the water supply tap fig 5A 2 Connect the water cleaner to the mains electricity supply via the omnipolar switch or by plugging the plug into the socket 3 Start the cleaner by t...

Страница 12: ...detergent suction control on the lance and spray the dirty surface with the diluted product working from bottom to top Let it react for a few minutes 3 Rinse the whole surface well from top to bottom with hot or cold water at high pressure 4 After using with detergent flush out the inlet place the de tergent suction hose fig 9 in a tank of clean water and let the pump run for 1 minute with the dos...

Страница 13: ... fuel and close the drain cap CLEANING THE WATER FILTER Clean the water intake filter regularly and free it from any impurities fig 18 CHANGING THE NOZZLE The high pressure nozzle fitted on the lance must be changed from time to time as this component is subject to normal wear during use Wear may generally be detected by a drop in the working pressure of the cleaner To replace it consult your supp...

Страница 14: ...uld be damaged by drying out such as the supply hoses When bringing back into use ensure that there are no cracks or cuts in the water supply hoses Oil and chemical products must be disposed of according to current legislation SCRAPPING If you decide that the cleaner is no longer to be used render it inoperative by removing the electric power cable Ensure that all parts of the cleaner that could b...

Страница 15: ...re clogged Thermostat setting Clogged filters Boiler coil clogged with scale No fuel Incorrect combustion Impurities or water in the fuel Tap turned off No detergent in the tank Control on the lance not switched on Coil or pipe clogged Gasket worn Oil seal rings worn Water in the fuel tank Fuel pressure incorrect Air throttle adjusted incorrectly Electrodes positioned incorrectly Fuel nozzle dirty...

Страница 16: ...l pump is faulty Fuel solenoid valve not working Fuse burnt out REMEDIES Contact Distributor for service Contact Distributor for service Refill the fuel tank Remove filter and clean using fuel and a brush Empty fuel tank clean and refill with clean fuel Contact Distributor for service Contact Distributor for service Contact Distributor for service Contact Distributor for service Contact Distributo...

Страница 17: ...hose m ft Power cable m ft Lance thrust N Hand arm Vibration m s2 Noise Lp dB A Lw dB A Weight kg lb Dimensions cm in 1 230 240 50 3 0 3000 100 1500 10 32 80 5 5 18 29 5 2 5 76 91 120 265 100x68x89 39x27x35 SUPER INDY DS 2016 T 3 400 415 50 10 32 80 5 5 18 7 4 7400 200 2900 1000 264 52 2 5 78 93 120 265 100x68x89 39x27x35 5 8 1 8 68 8 5 8 1 8 68 8 30 140 86 284 30 140 86 284 800 212 18 4 75 18 4 7...

Страница 18: ...Aussie Eco Clean Super Indy Operating Maintenance Manual 2020 Notes ...

Страница 19: ...vy duty motors Triplex pumps with brass head ceramic pistons Mild steel or stainless steel coil options 18 litre diesel fuel tank High pressure detergent injection Stainless steel cover steel chassis with bumper Low water cut out Low fuel sensor Timed Total stop auto shut down Safety thermostat Micro leak detection Class A no operator RTO certification required Optional protective cage Use steam f...

Страница 20: ... lance b high pressure hose c all fittings 3 Check power supply cable and plug for damage 4 Check water inlet filter clean if necessary MONTHLY 1 Check high pressure nozzle for wear If pressure has dropped off replace nozzle If you machine is used regularly the nozzle may need replacing monthly to maintain performance 2 Clean detergent suction filter 3 Change lance nozzle tip 4 Change oil 5 Check ...