background image

12    |

Aussie Eco-Clean Super Indy Operating & Maintenance Manual - 

2020

FIG.12

REGULATING  PRESSURE 

AND USING STEAM

(If available)

This  chapter  concerns  only 

those  models  provided  with 

the  “pressure  regulating”  de-

vice. The pressure regulator, 

fig. 12, allows the operator to 

adjust  the  working  pressure.  

When  knob  C  is  turned  in 

an  anti-clockwise  direction 

(B) (minimum),  the  working

pressure is reduced.

ADVICE ON USING DETERGENTS

 

This cleaner has been designed for use with the detergents 

supplied or recommended by the manufacturer.

The use of other detergents or chemicals may influence the 

safety of the cleaner.

1

For environmental compatibility

, we recommend a rea-

sonable use of detergents, according to the instructions 

on the pack.

2

From the range of recommended products, choose the

one most suited to the washing job to be done and dilute 

it with water according to the instructions on the pack or 

in the catalogue of the detergents most suited for the 

type of hot or cold water cleaner.

3

Ask your dealer for the detergents catalogue.

 

During use with boiling water, "Steam Phase", keep 

away from the openings for fumes discharge (risk of bur-

ning).

When  you  have  finished  using  the  "Steam  Phase",  turn 

the  thermostat  knob  "B"  to  position  "0"  (fig.  7)  and  let 

the machine cool down for about 3 minutes with the gun 

turned on.

OPERATING  PHASES  FOR  CORRECT  CLEANING  WITH 

DETERGENTS 

1

) Prepare  the  solution  of  detergent  at  the  concentration

most suitable for the type of dirt and the surface that is to be 

washed. 

2

) Start the cleaner, turn on the detergent tap (if present), switch

on the detergent suction control on the lance and spray the dirty 

surface with the diluted product, working from bottom to top. 

Let it react for a few minutes.

3

) Rinse the whole surface well from top to bottom with hot or

cold water at high pressure. 

4

) After using with detergent, flush out the inlet; place the de

-

tergent suction hose (fig. 9) in a tank of clean water and let the 

pump run for 1 minute with the dosing tap turned fully on and 

the lance in detergent delivery condition.

MAINTENANCE

ONLY THE OPERATIONS AUTHORIZED IN THIS IN-

STRUCTIONS MANUAL MAY BE CARRIED OUT BY THE 

USER.

ALL OTHER OPERATIONS ARE FORBIDDEN.

For maintenance of the boiler, high pressure pump, the 

electrical parts and all parts with a safety function, you must 

apply to our Technical service centre.

 

Disconnect the water cleaner from the mains electricity 

supply via the omnipolar switch or by unplugging the plug from 

the socket and close the water supply tap (see chapters on 

connecting to the electricity and water mains

)

 

before carrying 

out  any  maintenance  jobs.    Once  maintenance  has  been 

completed, ensure that the closing panels have been correctly 

reassembled and anchored with the screws provided before 

reconnecting the cleaner to the mains.

Failure to do so may cause a risk of electric shock.

PRECAUTIONS   AGAINST  FROST

The cleaner must not be exposed to frost.

  

If the cleaner is left in premises where it is exposed to frost, 

when work is over or for storage, antifreeze must be used to 

prevent serious damage to the hydraulic circuit. 

!

!

!

Use the steam nozzle (supplied as an accessory).

Turn the thermostat knob “B” (fig. 7) to steam position to obtain 

an increase in the temperature of the water at delivery.

At  work  temperatures  higher  than  95°C  (203°F),  the  work 

pressure must be < 32 bar (460 PSI).

Содержание Eco Clean Super Indy

Страница 1: ...Aussie Eco Clean Super Indy High Pressure Washer Operating Maintenance Instructions Read all instructions carefully BEFORE using your Super Indy steam cleaner AUSTRALIAN PUMP INDUSTRIES ...

Страница 2: ... a specific unwanted event and the potential consequences if it should occur RISK RANKING TABLE The consequences loss outcomes are combined with the likelihood of those outcomes in the risk ranking table to identify the risk rank of each loss event e g a consequence of Moderate with a likelihood of Likely yields a risk rank of 17 The table yields a risk rank from 1 to 25 for each set of probabilit...

Страница 3: ...sticker Disconnect from power before servicing machine Burns from steam or hot water Personal injury 14 Warning in Operating Instructions decals on machine Unsecured machine moves unattended Cause of accidents and or injury 8 Use of chocks behind wheels or ute mounting kit Dislodged particles in atmosphere Sight damage 20 Never clean asbestos with high pressure water Use of eye protection Slipping...

Страница 4: ... Preparation 5 Description of symbols 6 Introduction 7 Intended use 8 Preliminary operations 8 General warnings for installation use 10 Use advice on using detergents 12 Maintenance 12 Periods of inactivity 14 Scrapping 14 Trouble shooting 15 Technical data 17 Notes 18 Routine Check Lists 20 ...

Страница 5: ...teed against faults in manufacture for one year from purchase Keep your receipt as proof of purchase This guarantee is invalid if the product is found to have been abused in any way or not used for the purpose for which it was intended Routine maintenance is the owner s responsibility Failure to maintain the machine in line with the services outlined on Page 8 will invalidate warranty Where possib...

Страница 6: ... THE BURNER ADJUSTING THE WATER TEMPERATURE FUEL DIESEL CHEMICHALS DETERGENT ANTI SCALE PRODUCT DO NOT DIRECT THE JET AT PEOPLE ANIMALS POWER SOCKETS OR THE MACHINE ITSELF ATTENTION RISK OF BURNS ATTENTION RISK OF ELECTRIC SHOCK EARTH WATER INPUT WATER OUTPUT DESCRIPTION OF SYMBOLS ON THE CLEANER 6 ...

Страница 7: ... with the governing laws for electric safety in compliance with the provisions of the IEC 60364 1 standard It is necessary to check this essential safety requisite In case of doubt ask for accurate control of the power system by qualified personnel The manufacturer may not be considered responsible for dama ges occurred because of the lack of the grounding system The H P cleaner must be connected ...

Страница 8: ...nd potentially dangerous INTENDED USE This appliance is intended exclusively for cleaning machines vehicles buildings and general surfaces suitable for treatment with a high pressure jet of detergent solution between 25 and 250 bar 360 3600 PSI This appliance has been designed for use with the detergents supplied or recommended by the manufacturer The use of other detergents or chemicals may influ...

Страница 9: ...ial to know the function of the cleaner s command and control devices FIG 2 FIG 6 FIG 5 WATER CIRCUIT CONNEC TION Connect the feed hose to the mains fig 5A and to the hosetail on the cleaner fig 5B Check that the pressure and quantity of the water supplied by the mains are sufficient for the cleaner to work properly 2 to 8 BAR 29 to 116 PSI Maximum temperature of fee ding water 50 C 122 F Connect ...

Страница 10: ...he applian ce disconnecting it from the water main and from the electricity main via the omnipolar switch or by unplugging the plug in the case of water cleaners rated at less than 3 kW without tampe ring with it Apply to one of our technical service centres The use of any electric appliance requires the respect of some basic rules Do not touch the appliance with wet or damp hands or feet Do not u...

Страница 11: ... water cleaner causes serious dam age to pump gaskets FIG 7 FIG 8 USING THE CLEANER CONTROL PANEL A On off switch B Temperature regulator C Detergent control tap if available D Pressure gauge STARTING THE CLEANER 1 Turn on the water supply tap fig 5A 2 Connect the water cleaner to the mains electricity supply via the omnipolar switch or by plugging the plug into the socket 3 Start the cleaner by t...

Страница 12: ...detergent suction control on the lance and spray the dirty surface with the diluted product working from bottom to top Let it react for a few minutes 3 Rinse the whole surface well from top to bottom with hot or cold water at high pressure 4 After using with detergent flush out the inlet place the de tergent suction hose fig 9 in a tank of clean water and let the pump run for 1 minute with the dos...

Страница 13: ... fuel and close the drain cap CLEANING THE WATER FILTER Clean the water intake filter regularly and free it from any impurities fig 18 CHANGING THE NOZZLE The high pressure nozzle fitted on the lance must be changed from time to time as this component is subject to normal wear during use Wear may generally be detected by a drop in the working pressure of the cleaner To replace it consult your supp...

Страница 14: ...uld be damaged by drying out such as the supply hoses When bringing back into use ensure that there are no cracks or cuts in the water supply hoses Oil and chemical products must be disposed of according to current legislation SCRAPPING If you decide that the cleaner is no longer to be used render it inoperative by removing the electric power cable Ensure that all parts of the cleaner that could b...

Страница 15: ...re clogged Thermostat setting Clogged filters Boiler coil clogged with scale No fuel Incorrect combustion Impurities or water in the fuel Tap turned off No detergent in the tank Control on the lance not switched on Coil or pipe clogged Gasket worn Oil seal rings worn Water in the fuel tank Fuel pressure incorrect Air throttle adjusted incorrectly Electrodes positioned incorrectly Fuel nozzle dirty...

Страница 16: ...l pump is faulty Fuel solenoid valve not working Fuse burnt out REMEDIES Contact Distributor for service Contact Distributor for service Refill the fuel tank Remove filter and clean using fuel and a brush Empty fuel tank clean and refill with clean fuel Contact Distributor for service Contact Distributor for service Contact Distributor for service Contact Distributor for service Contact Distributo...

Страница 17: ...hose m ft Power cable m ft Lance thrust N Hand arm Vibration m s2 Noise Lp dB A Lw dB A Weight kg lb Dimensions cm in 1 230 240 50 3 0 3000 100 1500 10 32 80 5 5 18 29 5 2 5 76 91 120 265 100x68x89 39x27x35 SUPER INDY DS 2016 T 3 400 415 50 10 32 80 5 5 18 7 4 7400 200 2900 1000 264 52 2 5 78 93 120 265 100x68x89 39x27x35 5 8 1 8 68 8 5 8 1 8 68 8 30 140 86 284 30 140 86 284 800 212 18 4 75 18 4 7...

Страница 18: ...Aussie Eco Clean Super Indy Operating Maintenance Manual 2020 Notes ...

Страница 19: ...vy duty motors Triplex pumps with brass head ceramic pistons Mild steel or stainless steel coil options 18 litre diesel fuel tank High pressure detergent injection Stainless steel cover steel chassis with bumper Low water cut out Low fuel sensor Timed Total stop auto shut down Safety thermostat Micro leak detection Class A no operator RTO certification required Optional protective cage Use steam f...

Страница 20: ... lance b high pressure hose c all fittings 3 Check power supply cable and plug for damage 4 Check water inlet filter clean if necessary MONTHLY 1 Check high pressure nozzle for wear If pressure has dropped off replace nozzle If you machine is used regularly the nozzle may need replacing monthly to maintain performance 2 Clean detergent suction filter 3 Change lance nozzle tip 4 Change oil 5 Check ...