installation
and
user
manual
30
installation
3
INSTALLATION CHECKLIST
INSTALLATION MUST TAKE PLACE IN THE FOLLOWING ORDER
Suspension bracket installed
plumb and clear of combustibles.
Ceiling bracket to protrude
minimum 1͈ below ceiling. More
than 1͈ should only be used if the
roof space prohibits a 1͈ drop.
1͈ clearance gap between the bracket
and the ceiling. This gap will be
covered by the ceiling cover plate.
Lower active flue installed
BEFORE insultated flue & set to
correct height from floor.
Lower flue pushed up a minimum
of 8͈ into the ceiling bracket (8͈
measurement taken from the
point the lower flue enters the
ceiling bracket flue connector).
Mark the flue with chalk to assist
with this.
Flue seam facing the back of the
fire, if possible.
Grub screws tightened.
Flue adaptor pushed into the
top of the lower active flue as
far as it will go until it bottoms
out & sealed with a high temp
silicone sealant. If this is not done
correctly, it may result in a weak
draw.
Flue adaptor sealed correctly.
Insulated flue installed to make up
a total flue height (internal flue &
insulated flue) of 15� minimum.
2͈ minimum clearance from the
insulated flue to any combustible
material within the roof space.
Insulated flue sealed with silicon
sealant & flashing installed.
Braced ( if required). If necessary
precautions against capillary
action taken.
Anti-down draft cowl installed.
Firebox lifted into position evenly
to protect the shaft from damage.
Bearings and nut installed in the
correct order and tightened to close
the gap between firebox and lower
flue to approximately 3/64͈ . Firebox
rotates freely, if required.
important
This must be ticked and signed by the person
who installs your fire and returned to aurora
suspended fires following installation for any
warranty claims to be honoured.
name
siGnature
date
Содержание THE AETHER SUSPENDED FIRES
Страница 2: ......
Страница 5: ...1 DIMENSIONS SPECIFICATIONS...
Страница 6: ...06...
Страница 9: ...aurora suspended fires 09 2 PLANNING...
Страница 10: ...10...
Страница 17: ...aurora suspended fires 17 3 INSTALLATION...
Страница 31: ......
Страница 32: ...61 0 2 6686 8408 65 Piper Dr Ballina NSW 2478 Australia www aurorasuspendedfires com Aurora...