Introduction 

Thank you for purchasing Aurora AL500.    Aurora is a powerful laser that integrates computer, software 

and laser projector into one unit.  It is an ideal product for disco, club, bar, exhibition, commercial 

display and any place that need visionary effect. For safe operation, read this manual before powering 

or installing the fixture, follow the safety precautions listed below, and observe all warnings printed in 

this manual and on the fixture. 

 

Safety Precautions 

„

 

Do not spill liquids into or onto your unit. If this ever happens, disconnect the main power immediately.    Do 

not connect this unit to any dimmer pack. 

„

 

Always disconnect from main power before making any type of connection. 

„

 

Be sure to locate this unit in a place with adequate ventilation at least 15 cm from a wall, and mount this unit in 

safe and stable matter. 

„

 

To prevent fire or shock hazard, do not expose this unit to a high temperature or high humidity area.    Please 

unplug unit when not in use. 

„

 

Always keep combustible materials away from the fixture. 

„

 

Class 3B laser should be mounted at or above 3 meters height.    Project Class 3B laser light above eye level. 

Do not project Class 3B Laser light on specular material. 

„

 

The entrance to area where Class3B laser is used should be posted with appropriate warning signs.   

„

 

This unit is intended for indoor use.    Use of this unit outdoors voids all warranties. 

„

 

Always refer service to a qualified technician.    Never look directly into laser beam. 

„

 

Occasional breaks are necessary to prevent breakdowns. 

„

 

Caution - Use of controls or adjustments or performance of procedures other than as specified herein 

may result in hazardous radiation exposure!

 

 

Set Up 

Unpacking

 Aurora comes with: 2 Keys, 1 hanging bracket, 2 clamp levers, 2 washers, 1 power cord 

and 1 user manual.    Unpack carefully and be sure that no damage has occurred during shipping.   

If there is anything missing or appear to be damaged please contact your dealer. 

Power Connection

 Be sure the source voltage in your area matches the required voltage for your 

Aurora before plugging your unit in. Incorrect voltage selection will detrimentally affect the operation 

of this product. 

DMX Cable Connection 

Aurora is a seven-channel DMX fixture that can be operated with universal 

DMX controller.    This unit and DMX controller require a standard 3-pin XLR connector for data input 

and data output.   

Installation/Mounting 

Aurora

 

should be properly mounted by using a suitable hanging clamp and 

safety cable.    Use in a well-ventilated area. Be sure no ventilation slots are blocked. 

 

 

Содержание AL500 Series

Страница 1: ...0 Series User Manual Your Best Mate in Laser Lighting 2006 ACTOR MATE CO LTD No 15 Lane 83 Lungshou St Taoyuan City Taiwan 330 R O C Tel 886 3 3791326 Fax 886 3 3791919 www actlaser com tw active actl...

Страница 2: ...ht on specular material The entrance to area where Class3B laser is used should be posted with appropriate warning signs This unit is intended for indoor use Use of this unit outdoors voids all warran...

Страница 3: ...tributor The quotation and production time will be sent back to client as soon as we receive mentioned material Draft drawing and video clip will be provided to client for confirmation during producti...

Страница 4: ...her one is logo geometric pattern program To perform beam show program press FUNC button and select F7 and then press VALU button to set its value to Y Press SAVE button to save the setting LED displa...

Страница 5: ...firm the setting is saved well Auto Sound Active setting Repeat above setting procedures of Auto Sound Active mode introduced in Stand Alone operation introduction 5 DMX Operation To run this unit in...

Страница 6: ...Rotate clockwise 6 3 208 233 150ms 66 87 Select 11 positions for G24 196 199 Rotate clockwise 8 3 243 255 200ms 88 109 Select 11 positions for G25 200 203 Rotate clockwise 10 3 110 131 Select 11 posi...

Страница 7: ...n action 31 various sizes of graphic from small to big 130 155 75ms CH1 150 174 animation 0 63 No action 64 127 Mirror effect 128 191 Mirror effect Rotate counterclockwise 90 4 192 255 Rotate counterc...

Страница 8: ...G32 G42 G3 G13 G23 G33 G43 G4 G14 G24 G34 G44 G5 G15 G25 G35 G45 G6 G16 G26 G36 G46 G7 G17 G27 G37 G47 G8 G18 G28 G38 G48 G9 G19 G29 G39 G49 G10 G20 G30 G40 G50 G51 G60 10 Preset sample logos or custo...

Страница 9: ...el by Sensitivity Adjustment Knob If the beam is fuzzy please refer to cleaning section to clean the mirror first If problems cannot be solved please contact your dealer for service Fuse Replacement A...

Страница 10: ...e fixture operates Cleaning case Use a soft cloth and normal glass cleaner to clean the casing Be sure to dry all parts before plugging the unit back in Specifications Product Name Aurora Model No AL5...

Отзывы: