Signing out device from RTH receiver

1

.

Signing  out  the  device  from  the  RTH 

receiver  is  initiated  by  pressing  the  right 
sign  out  button  (red  triangle

 

-

      )

  on  the 

receiver  and  pressing  it  for  at  least  2  sec, 
until the LED diode starts flashing with a red 
light, then we release the button.

 

Note

The receiver is waiting for signing out 

of the device for 120 seconds. After this time 
it  will  automatically  return  to  normal 
operation.

7

OFF
ON
IN
OUT

LED

2

.

When the LED diode of the receiver flashes with a green light, press the 

"association button" on the device that you want to sign out and hold it 
pressed for at least 2 seconds (precise signing out manual is attached to 
each device).

.

3

.

Correct completion of signing out is signalled by the stop of flashing with a 

red light of the LED diode on the receiver and the receiver going into normal 
operation.

 

In the case of an error, steps 1 and 2 should be repeated.

RESETTING - Signing out all devices
assigned to receiver

In order to sign out all devices associated with the 
receiver  press  and  hold  at  the  same  time  both 
association and sign out (

       

and 

     

) buttons for at 

least  5  seconds  until  signalling  of  the  LED  diode 
changes to alternate flashing in colours green and 
red. Then release both buttons.

 

Correct completion of signing out of all devices is 
signalled  after  approximately  2  seconds  by 
signalling change to green and then its fading

.

AURATON RTH

OFF
ON
IN
OUT
ALARM

RESET

Note

If after RESETTING we disconnect the receiver from the power supply 

and  then  we  connect  the  power  supply  again,  the  receiver  will 
automatically go into the "association" mode, just as at the first start-up.

Содержание RTH

Страница 1: ...User s Manual RTH www auraton pl OFF ON IN OUT ALARM RESET ...

Страница 2: ...reeoperationofthedevice LEDdiodes LED diodes inform in a clear manner about the device operating status ON OFFcyclesmemoryalgorithm The AURATON RTH receiver is equipped with a unique algorithm of ON OFF cycles analysis The whole heating cycle from the last 24h is saved in the memory of the RTH receiver In the case of loss of communication with the temperature controller and or the T 2 thermometer ...

Страница 3: ... device is on the contacts COM andNOareclosed The LED flashes green the RTH receiver awaits the device tobepaired The LED flashes red the RTH receiver awaits the device tobederegistered TheLEDflashesalternatingredandgreen ALARM the RTH receiver has lost connection with one of the paireddevices RESET receiverderegistersallpreviouslypaireddevices Legend description of LED signalling hole for fasteni...

Страница 4: ...s from the lower and upper part of the AURATON RTH receiver 2 Take off cable tie clamps from the lower and upper part of the AURATON RTH receiver protective cover cable tie clamp NOTE When installing the AURATON RTH receiver its power supply must be disconnected It is recommended that the installation is performed by a qualified specialist 230V AC 5 After connecting the conductors they must be sec...

Страница 5: ...receiver to the wall with screws making sure they hold thereceiversecurely Fastening the RTH receiver to the wall NOTE If the wall is wooden there is no need to use wall plugs In such a case drill two holes 2 7 mm in diameter instead of 5 mm and screw thescrewsdirectlyintothewood NOTE The RTH receiver cannot be placed in metal containers e g anassemblybox ametalenclosureofaheater inordertonotto in...

Страница 6: ...tton green triangle on the receiver and pressing it for at least 2 seconds until the LED diode starts flashing with a green light then we releasethebutton Note Thereceiveriswaitingforassociationfor 120 seconds seconds After this time it will automaticallyreturntonormaloperation 2 When the LED diode of the receiver flashes with a green light press the associationbutton onthedevicethatyouwanttoassoc...

Страница 7: ...on of signing out is signalled by the stop of flashing with a redlightoftheLEDdiodeonthereceiverandthereceivergoingintonormal operation Inthecaseofanerror steps1and2shouldberepeated RESETTING Signing out all devices assigned to receiver In order to sign out all devices associated with the receiver press and hold at the same time both association and sign out and buttons for at least 5 seconds unti...

Страница 8: ...elements heating device AURATON RTH A simplified schematic of connecting the AURATON RTH receiver with the heating device The T 1 controller enables setting the temperature and or its controlling The T 2 thermometer gives information about the current temperaturewithoutthepossibilityofitsmanualchange AURATON T 1 Wireless temperature sold separately Basic configuration of devices AURATON T 2 AURATO...

Страница 9: ...Thanks to such solution the baby room will always have a temperature of 22 C regardless of the temperaturefluctuationsthatoccurinthekitchen C factory setting 20 C If with the RTH receiver we associate only the T 2 thermometer it is not possible to manually set the temperature and the RTHreceiverwillmaintainthefactorysettingof20 C 9 ATTENTION 1 The order of associating the T 1controller and T 2 the...

Страница 10: ...handle The RTH receiverwillmaintainthetemperatureof18 Cintheroom C Windowopen When we open the window with an associated H 1 handle for longer than 30 sec the transmitter in the RTH AURATON receiver will be turned off and the heating device will also turn off If all assigned windows once again will be in a position different than open the RTH receiver will return to normal cooperationwiththeT 1con...

Страница 11: ...ith air conditioning device air conditioning device 230 VAC AURATON RTH N L Max 16A Cooperation of the RTH receiver with the H 1 handles without the T 1 controller and the T 2 thermometer A Air conditioningcontrolling InorderfortheRTHreceivertobeabletocontrolair conditioning itcannotbetheassociatedwithanyT 1controllerorT 2thermometer it must be associated with at least one H 1 handle or window pos...

Страница 12: ...s is an intentional delay so as to prevent too rapid changes of air conditioning devices between ON OFF position which can lead to compressordamage B Lossofsignal When the RTH receiver loses signal from the associated H 1 handle or window position sensor 3 subsequent lost transmissions it changes thestatusofthiswindowtoclosed Afterrestoringthetransmissiononce againthesensoriscorrectlyreadbytherece...

Страница 13: ...H receiver and associated the T 2 thermometer without the T 1 controller the RTH receiver will maintain constant temperature factory set at 20 C If we slightly open any window with associated H 1 handle the temperature of 17 C will be maintained If any window with associated H 1 handle will be opened the RTH receiver will turn off the heating device but it will activateitagainifthetemperaturefalls...

Страница 14: ...ply restoration After receiving the signal the RTHreceiverwillgointonormaloperation ź Do not place the RTH receiver in metal casings e g installation boxes metalfurnacecasings soasnottodisturbthecontrolleroperation 14 ź Switching of the transmitter is synchronized with the course of supply network 230 V so as to ensure that short circuit and opening of contacts of the transmitter always proceed in...

Страница 15: ...otherwastefromthehousehold The User is obliged to hand it over to the electronic and electrical equipmentwastecollectionpoint Technical specifications Work cycle daily Verification of operation condition LED diode Maximum load current 16A 250 VAC for transmitter contacts RTH power supply 230 VAC 50 Hz Radio frequency 868 MHz Range of operation in a typical building with a standard with wireless de...

Страница 16: ...www auraton pl ...

Отзывы: