Additional information and comments
ź
Wireless devices associated with the RTH receiver should be installed
minimum 1 meter away from the RTH receiver (a signal from the
transmitters that is too strong may cause interruptions).
ź
Between the next turning off and on of the transmitter at least
30 seconds must pass.
ź
Transmission of data from the T-1 controller to the RTH receiver happens
at each change of the environment temperature by 0.2°C. When the
temperature does not change, the T-1 controller sends data every
5 minutes (it is reflected by LED diodes flashing on the T-1controller and
LED diodes flashing on the RTH receiver - with an orange light)
ź
At power supply failure the RTH receiver will be deactivated. After
restoration of power supply the heating device will be automatically
activated and the RTH receiver will be expecting the nearest signal from
associated transmitters (this signal should arrive not later than within
5 minutes after power supply restoration). After receiving the signal the
RTH receiver will go into normal operation.
ź
Do not place the RTH receiver in metal casings (e.g.. installation boxes,
metal furnace casings) so as not to disturb the controller operation.
14
ź
Switching of the transmitter is synchronized with the course of supply
network 230 V so as to ensure that short circuit and opening of contacts
of the transmitter always proceed in the area of the course of passage
of voltage system by zero. It prevents the formation of an electrical arc
and significantly increases the durability of the transmitter.
ź
The AURATON RTH receiver is equipped with a unique algorithm of
ON-OFF cycle analysis. The whole heating cycle from the last 24h is saved
in the memory of the RTH receiver. In the case of loss of communication
with the T-1 controller and/or the T-2 thermometer, the RTH receiver will
automatically perform the remembered ON/OFF cycle from the last 24h.
It gives time to restore the transmission (removal of interruptions)
or repair the T-1 controller and/or the T-2 thermometer without
significant thermal comfort deterioration in the controlled facility.
Unique features of AURATON T-1 RTH