Cooperation with the AURATON R25 RT regulator and/or the 

AURATON T-2 thermometer as well as the AURATON H-1 handles

By  default,  the  AURATON  RT  receiver  does  not  have  any  AURATON  H-1  handle  or 

AURATON W-1 window position sensor paired, therefore the relay is controlled by the 

paired AURATON R25 RT regulator and/or the AURATON T-2 thermometer. When at least 

one H-1 handle  is paired with the RT receiver, the relay is controlled in the following 

manner:

A) The window is closed or trickle-ventilated (micro-ventilation).
 

When the H-1 window handles is paired with the receiver, and all windows are closed 

or trickle-ventilated, the relay still maintains the setpoint from the paired AURATON 

R25 RT regulator and/or the T-2 thermometer.

B) The window is pivoted.

  If at least one window is pivoted, the temperature set in the AURATON R25 RT regulator 

is lowered in AURATON RT receiver down to 3°C. This state will be maintained until 

closing. This state will last until all windows are closed or trickle-ventilated.

C) The window is opened.
 

When  you  open  a  window  equipped  with  the  H-1  handle    paired  for  longer  than 

 

30 seconds, the relay in the AURATON RT receiver is switched off, as is the connected 

heating device. If all the assigned windows are again in a state other than “opened”, 

the RT receiver returns to normal cooperation with the AURATON R25 RT regulator 

and/or the T-2 thermometer no earlier than 90 seconds after switching off the relay. 

The purpose of this delay is to prevent too rapid transitions of the connected heating 

devices between the ON and OFF states. However, if the temperature in the room 

drops below 7°C, the relay inside the receiver is switched on regardless of the positions 

of windows in order to prevent the room from freezing.

D) The signal is lost.

  When the RT receiver has lost the signal from the H-1 handle  paired (3 consecutive 

transmissions  are  lost),  it  changes  the  status  if  this  window  to  “closed”.  When  the 

transmission is restored, the H-1 handle is again properly read off by the RT receiver.

Содержание R25 RT

Страница 1: ...RT O W N E R S M A N U A L EN www auraton pl ...

Страница 2: ...ributes to the low wear of relay contacts Interference free communication between devices The transmitter and the receiver from the AURATON R25 RT set communicate at the frequency of 868 MHz Very short encrypted data transmission packets approx 0 004 s ensure very efficient and interference free operation of the device LED LED s diode indicates the operation mode status of the controller AURATON R...

Страница 3: ...ing devices with the RT receiver The LED light s green the output device is off the contacts COM and NC are closed The LED light s red the output device is on the contacts COM and NO are closed The LED flashes green the RT receiver awaits the device to be paired chapter Pairing the AURATON R25 RT wireless regulator and the RT receiver The LED flashes red the RT receiver awaits the device to be der...

Страница 4: ...rom the controllers The cables may be routed from the bottom of the receiver by breaking out holes in the mounting cover or from the back of the receiver if the cables are extended from the wall In order to connect the cables from the back the cover must be broken out 1 Take off the cover of the front part of the AURATON RT receiver by unscrewing the screws half way out 2 Connect the heating devic...

Страница 5: ... g an assembly box a metal enclosure of a heater in order to not to interfere with its operation 1 Take off the covers from the front part of the controller see chapter Installation of the AURATON RT receiver 2 Mark the location of the holes for the fastening screws on the wall 3 In the marked locations drill holes with diameters appropriate for the diameters of the enclosed wall plugs 5 mm 4 Put ...

Страница 6: ...URATON R25 RT controller with the AURATON RT receiver is initiated by pressing the right pairing button green triangle a single sound signal is emitted on the AURATON RT receiver and by holding it pressed for at least 3 s until the LED diode starts blinking with green light double sound signal then the button must be released The AURATON RT receiver waits for pairing for 120 seconds After this per...

Страница 7: ...red and after it is switched off it is green In the event of an unpairing error steps 1 and 2 must be repeated If more errors occur all devices must be unpaired see RESET Unpairing all devices paired with the AURATON RT receiver NOTE If the power supply of the AURATON RT receiver is switched off and then switched on after the RESET the receiver automatically goes into the pairing mode for 120 seco...

Страница 8: ...ected to the heating device Wireless thermometer sold separately Window handle sold separately Wireless temperature regulator heating device A simplified schematic of connecting the AURATON RT receiver with the heating device AURATON RT AURATON T 2 AURATON H 1 AURATON R25 RT Additional system devices ...

Страница 9: ... be able to change it in that room you install the T 2 thermometer and the AURATON R25 RT regulator in e g the kitchen This way the temperature in the children s room will always be at 22 C regardless of temperature fluctuations in the kitchen C The factory setpoint 20 C if the T 2 thermometer is the only device paired with the RT receiver it is not possible to set the temperature manually and the...

Страница 10: ...e maintained until closing This state will last until all windows are closed or trickle ventilated C The window is opened When you open a window equipped with the H 1 handle paired for longer than 30 seconds the relay in the AURATON RT receiver is switched off as is the connected heating device If all the assigned windows are again in a state other than opened the RT receiver returns to normal coo...

Страница 11: ...T 2 thermometer signal returns the receiver uses the last memorised setpoint value and maintains it while signalling the error When the H 1 handles the T 2 thermometer and the AURATON R25 RT regulator the temperature is measured with the T 2 thermometer are paired with the receiver then maintaining the work cycle from the last 24 hours occurs only after losing the signal from the T 2 thermometer W...

Страница 12: ...12 CONTROL PROTECTIVE HEATING DEVICE e g a gas furnace ELECTRIC HEATING DEVICE 230V AC The AURATON RT receiver connection schematics MAX 230V 16A ...

Страница 13: ...02 96 EU and the Act concerning used up electric and electronic equipment such a marking indicates that this equipment may not be placed with other household generated waste The user is responsible for delivering the devices to a reception point for used up electric and electronic equipment Clean the outside of the device with a dry cloth Do not use from solvents such as benzene thinner or alcohol...

Страница 14: ...14 ...

Страница 15: ...15 A template for drilling holes for fastening the AURATON RT receiver 1 1 scale ...

Страница 16: ...www auraton pl ver 20190408 ...

Отзывы: