Operation

Base  Operation

Emergency operation and test operation

Emergency Operation:

Use this operation only when the remote controller is defective 

or lost, and with function of emergency running, air conditoner

can run automatically for a while.

When the emergency operation switch is pressed, the " Pi "

sound is heard once, which means the start of this operation. 

When power switch is turning on for the first time and

emergency operation starts, the unit will run automatically in 

1

Remote controller

FAN

TIMER

4 3

CONFIRM

SMART

CANCEL

COOL

HEAT

DRY

the following modes:

2

Pi

    Room

Designated

Timer

Fan Operation

SLEEP

EXTRA

FUNCTION

SWING

temperature

temperature

mode

speed

mode

TURBO/QUIET

  Above 23

o

C

 26

o

C

No

AUTO COOL

  Below 23

o

C

 23

o

C

No

AUTO HEAT

It is impossible to change the settings of temp. and fan speed,It 

is also not possible to operate in timer or dry mode.

Test operation:

Test operation switch is the same as emergency switch.

Use this switch in the test operation when the room

temperature is below 16

o

C, do not use it in the 

normal operation.

Continue to press the test operation 

switch for more than 5 seconds . After

 you hear the "Pi" sound twice, release

 your finger from the switch: the cooling

operation starts with the air flow speed "Hi".

Under this operation mode,the fan motor of indoor

Pi Pi

3.Select temp.setting

Press

button

Every time the button is pressed, temp.setting

increase 1

o

C,if kept depressed, it will increase

rapidly

Every time the button is pressed, temp.setting

decrease 1

o

C,if kept depressed, it will 

unit will run in high speed.

   Air Flow Direction Adjustment

decrease  rapidly

Select a desired temperature.

1.Vertical flap

Remote controller

4.Fan speed selection

COOL/DRY/AUTO(Initial state):

HEAT(Initial state):

Press FAN button. For each press, fan speed

changes as follows:

Remote controller:

Pos.1

Pos.2
Pos.3
Pos.4
Pos.5

Display

circulated

LOW

MED

HI

AUTO

(Autoswing)

(no)

Air conditioner is running under displayed fan speed.

When FAN is set to AUTO, the air conditioner

automatically adjusts the fan speed according to room

temperature.

2.

SWING

Press          button.  changes as follows: Pos.4

SWING

Press           button again ,

vertical flap will stop over

present position,

the swing function will be cancelled

Operation

Remote

Mode

Controller

Note

EXTRA

Under the mode of smart operation, air conditioner will

automatically select Cool or Heat operation according to

room temperature. When FAN is set to AUTO the air 

conditioner automatically adjusts the fan speed according

to room temperature.

3.Press

FUNCTION

button

  to choose the  Pos.2 and Pos.3.

SMART

Cooling only unit do not have  displays and functions 

related with heating

COOL

When adjusting the flap by hand,turn off the unit.

When humidity is high,condensate water might occur

adjusted to left or at air outlet if all vertical louvers are right.

It is advisable not to keep horizontal flap at downward

position for a long time in COOLor DRY mode ,

otherwise, condensate water might occur.

Note:

When restart after remote turning off, the remote controller

controller will automatically memorize the previous set swing position.

In DRY mode , when room temperature becomes lower

than temp.2

o

C, unit will run intermittently at LOW 

speed regardless of FAN setting. 

DRY

In HEAT mode, warm air will blow out after a short

period of the time due to cold - draft prevention function.

When FAN is set to AUTO,the air conditioner automatically

adjusts the fan speed according to room temperature.

HEAT

In FAN operation mode , the unit will not operate in COOL or

HEAT mode  but only in FAN mode, AUTO is not available in

FAN mode. And temp. setting is disabled. In FAN mode,

sleep operation is not available.

FAN

2

1. Unit start

Press ON/OFF on the remote controller, unit starts.

2. Select operation mode

COOL button:Cooling mode

HEAT button: Heating mode

DRY button: Dehumidify mode

Содержание AR35TK-IN

Страница 1: ...T TYPE ROOM AIR CONDITION OPERATION MANUAL ER Please read this operation manual before using the air conditioner Keep this operation manual for future reference This appliance is filled with R32 AR35T...

Страница 2: ...ontacts should not be no less than 3mm Such means for disconnection must be incorporated in the Make sure installation is done according to local wiring regulation by professional persons A leakage ex...

Страница 3: ...9 1 2 8 5 10 Contents PARTS AND FUNCTIONS OPERATION INDOOR UNIT INSTALLATION MAINTENANCE CAUTIONS TROUBLE SHOOTING...

Страница 4: ...he 4 4 Load the battery then put on the cover again Note The distance between the signal transmission head and the rece iver hole should be within 7m without any obstacle as well When electronic start...

Страница 5: ...ontroller Pos 1 Pos 2 Pos 3 Pos 4 Pos 5 Display circulated LOW MED HI AUTO Autoswing no Air conditioner is running under displayed fan speed When FAN is set to AUTO the air conditioner automatically a...

Страница 6: ...ffect of not too cool or not too warm 1 hr Rises 1O C 1 hr Rises 1O C Temp setting Unit stop In COOL DRY mode In HEAT mode 2 1 hours after SLEEP mode starts temp will become 2O C lower than temp setti...

Страница 7: ...ON CONFIRM CANCEL CONFIRM CANCEL All the products are in conformity with the following European provision RoHS The products are fulfilled with the requirements in the directive 2011 65 EU of the Europ...

Страница 8: ...disturbed Place possible to drain easily where piping can be conne cted with the outdoor unit Place where cold air can be spread in a room entirely Place nearby a power receptacle with enough space ar...

Страница 9: ...nloading of indoor unit body Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Refer to the previous article When the mounting plat...

Страница 10: ...re tool for R410A Conventional are tool Clutch type clutch type Rigid type Wing nut type Imperial type A 0 0 5mm 1 0 1 5mm 1 5 2 0mm rth leakage breaker Lean Damage of are Partial Too outside Correct...

Страница 11: ...door unit using vacuum cleaner or flaping them lightly otherwise its performance will be affected the cool and dry conditions For Smart Use of The Air Conditioner Replacement of Air Purifying Filter T...

Страница 12: ...TION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or re...

Страница 13: ...es have Cautions 3 If the fuse of indoor unit on PC board is it with the type of T 3 15A 250V outdoor broken change it with the type of T 25A 250V The refrigerating circuit is leak proof 1 Applicable...

Страница 14: ...saben los peligros involucrados Los ni os no deben jugar con el aparato La limpieza y el mantenimiento del aparato no se realizar n por los ni os sin supervisi n El m todo de cableado debe cumplir el...

Страница 15: ...los Si se instalan l mparas fluorescentes o se utilizan tel fonos inal mbricos en la sala el receptor podr a resultar perturbado al recibir las se ales por lo que la distancia hasta la unidad interior...

Страница 16: ...ustar autom ticamente la velocidad del mismo seg n la temperatura de la habitaci n posici n actual y la funci n de oscilaci n quedar cancelada 3 Pulse el bot n EXTRA FUNCTION Cambiar a Pos 2 Pos 3 Pre...

Страница 17: ...iveles eficaces de calefacci n o refrigeraci n de temperatura La unidad se detiene En los modosde REFRIGERACI yN SECO 2 En el modo CALEFACCI N 1 hora despu s de que se haya iniciado el modo SUE O la t...

Страница 18: ...ciclo ilustrado a continuaci n Mando a distancia 1 Despu s de establecer la funci n de flujo del aire saludable la posici n de la rejilla se fijar 2 En el modo de calefacci n es mejor seleccionar el...

Страница 19: ...ed col quelo donde la unidad interior pueda recibir su se al mientras est n encendidas las l mparas fluorescentes de la sala Antes de insertar el enchufe de alimentaci n en la toma compruebe que el vo...

Страница 20: ...de la parte delantera A continuaci n con ctelos 3 Cubra la cara de sellado con aceite refrigerante y conecte los tubos Cubra la conexi n con material aislante de calor y aseg rese de fijarla con cinta...

Страница 21: ...Instale el manguito de drenaje formando una pendiente descendiente No practique el drenaje como se muestra a continuaci n Deposite agua en la bandeja de drenaje de la unidad interior y confirme que el...

Страница 22: ...rovocar defectos Cierre la rejilla de la toma de entrada 1 2 3 4 5 Una vez cada dos semanas Sustituci n del ltro puri cador de aire 1 Abra la rejilla de la toma de entrada Sujete la rejilla de la toma...

Страница 23: ...uir el aparato personalmente Conecte el cable de conexi n a tierra Precauciones ADVERTENCIA Llame al departamento de ventas asistencia t cnica si desea obtener m s informaci n acerca de la Instalaci n...

Страница 24: ...ten puertas o ventanas abiertas z Penetra la luz solar directamente a trav s las ventanas durante el funcionamiento en modo de refrigeraci n Utilice cortinas z Existen demasiadas fuentes de calor o de...

Страница 25: ......

Страница 26: ...as sensoriais ou mentais ou falta de experi ncia e conhecimento sempre que eles tenham recebidos supervis o ou instru o relaciona a utiliza o do aparelho de forma segura e tenham compreendidos os risc...

Страница 27: ...er odo de tempo Se o visualizador estiver ativo depois de retirar as pilhas prima o bot o RESET 1 7 Visualiza o TEMP temperatura 8 Visualiza o de outras fun es 9 Bot o TURBO QUIET 10 Bot o HEAT Quente...

Страница 28: ...o apenas quando o comando estiver estragado ou perdido Com o modo emerg ncia o aparelho pode funcionar automaticamente por algum tempo Quando o interruptor de emerg ncia acionado o som Pi ouvido uma v...

Страница 29: ...da de forma n o homog nea Um per odo longo em modo QUIET vai causar um efeito ameno na temperatura 1 hr Aumenta 1 C 1 hr Aumenta 1 C Defini es temperatura Unidade p ra Modo COOL DRY 2 Modo HEAT 1 hora...

Страница 30: ...kg A CONFORMIDADE DOS MODELOS SEGUNDO AS NORMAS EUROPEIAS Todos os produtos est o em conformidade com a seguinte provis o Europeia Os produtos est o feitos de acordo com os requisitos da diretiva 2011...

Страница 31: ...facilmente e onde tubos podem ser conectados para a unidade exterior Local onde o ar fresco pode ser distribu do livremente pelo quarto Local com muito espa o e pr ximo de uma tomada el trica Local on...

Страница 32: ...rior exterior e depois remova da parte conectada o isola o de calor do componente de liga o Fixar pela primeira vez a placa de montagem 1 Nivele corretamente o placa e fixe a contra a parede com a aju...

Страница 33: ...de tubo Sobre a drenagem A fia o Por favor deite gua pela canaliza o da unidade interior e confirme que a drenagem feita corretamente Para o caso de a mangueira de drenagem estar num quarto aplica is...

Страница 34: ...r descolora o ou deforma o Limpar o filtro de ar 1 Abra a grelha de entrada puxando a para cima 2 Remova o filtro Puxe a aba central do filtro ligeiramente at ser retirado do trav o e remova o filtro...

Страница 35: ...entrada de ar N o inicie nem termine o funcionamento pela liga o ou desconex o do cabo de alimenta o Use a voltagem correta 1 N o use o cabo de alimenta o estendido ou conectado a meio 2 N o instalar...

Страница 36: ...aquecimento ou demasiadas pessoas no espa o durante a opera o de refrigera o 1 Intervalo aplic vel de temperatura ambiente 6 A pilhas usadas devem ser acondicionadas corretamente M ximo D B 35 C Inter...

Отзывы: