BATTERY RECHARGING AND STATUS 

Please recharge the battery only with the supplied AC 

adapter. The AC adapter will automatically recharge 

the battery pack when plugged into the device. Please 

note that the battery pack will stop charging if the unit is 

powered ON for use. Always unplug the AC adapter when 

the battery pack is fully recharged to maintain the battery 

service life.

Note:

 When the battery is completely exhausted the 

power lights will flash 5 times and then power off the 

device.

Note:

 When the battery pack is completely recharged, 

the power lights will turn off to indicate unit readiness.

Note:

 Before using the battery pack, the plastic pole 

protector cover on battery pack must be removed.

 

Note:

 ONLY use Avya’s supplied battery pack for the 

device. Tampering with the battery pack will void the 

product warranty. We recommend replacing the battery 

pack after one year of regular use.

Always disconnect the AC adapter from the mains 

connection and the Avya unit before inserting battery 

pack. Check the LED power status of battery pack before 

use.

no power

medium power

low power

sufficient power

full power

Содержание AVYA

Страница 1: ...USER MANUAL A V Y A S T E A M I N H A L E R...

Страница 2: ...time This device should be used according to the instructions and not for any other purpose Please read instruction carefully before use WARNING AND CAUTION PRECAUTIONS Read instructions before using...

Страница 3: ...DESCRIPTION OF DEVICE AND ACCESSORIES 1 Main unit 2 Mouthpiece 3 Temperature increase button 4 Power On Off button 5 Temperature indicator 6 Temperature decrease button 7 Water Tank 8 Contact Electro...

Страница 4: ...ure Please note The unit comes only 50 pre charged for safety of transport ASSEMBLING THE WATER TANK Remove the device from the packaging Connect the water tank to the Steam Inhaler main unit Make sur...

Страница 5: ...ower Avya for about 2 hours Complete battery recharge time is approximately 3 hours Ensure that the plastic poles protector is removed from the battery before inserting it into the device Insert batte...

Страница 6: ...es and then power off the device Note When the battery pack is completely recharged the power lights will turn off to indicate unit readiness Note Before using the battery pack the plastic pole protec...

Страница 7: ...listed on the type plate Insert the AC adapter connector into the connector socket provided and the AC adapter fully into a suitable socket Note The device can operate without the battery pack when co...

Страница 8: ...s Solution into the water tank Close the water tank by pressing the latch firmly and securely back into place Fig 4 Inhalation with the mouthpiece Connect the rubberized mouthpiece to the steam outlet...

Страница 9: ...Fig 5 Fig 6 45 o Fig 7 LED indicators COOL LOW 40o C MEDIUM 45 o C Increase temp Decrease temp HIGH 55 o C...

Страница 10: ...ogy component allow at least 1 hour interval between each treatment CLEANING Note The Avya Steam Inhaler device and accessories are intended for multiple use Before you clean the device always switch...

Страница 11: ...Note NEVER ATTEMPT TO CLEAN THE MESH WITH ANY FOREIGN OBJECT THIS COULD DAMAGE THE MESH AND WATER TANK The unit will not operate with a damaged mesh Fig 8 Fig 9...

Страница 12: ...t Solution B Run the reverse self cleaning procedure with a solution mix of 2 drops vinegar to 4 drops of water refer to the reverse self cleaning instructions If the problem persists after checking a...

Страница 13: ...n device Check to see if battery pack is properly inserted in control unit Power lights on but no atomization Clean mesh as recommended in the instructions Check mesh to see that it is not damaged Cle...

Страница 14: ...rating Mesh Dimensions LxWxH Approx 52 5 x 52 x 126mm Device weight excluding batteries Battery Life Approx 2 hrs from 100 Recommended Fill Approx 20 ml maximum Atomization rate Approx 0 25 ml min min...

Страница 15: ...ions Misuse Improper maintenance Ordinary wear For warranty and service please contact AURA MEDICAL LLC at 516 253 1063 to speak to a representative or find us online at www aura medical com support I...

Страница 16: ...CISPR 11 RF emissions CISPR 11 Harmonic emissions IEC 61000 3 2 Voltage fluctuations flicker emissions IEC 61000 3 3 The MODEL SI20 uses RF energy only for its internal function Therefore its RF emiss...

Страница 17: ...fast transient burst IEC 61000 4 4 Conducted distur bances induced by RF fields IEC 61000 4 6 Surge IEC 61000 4 5 2 kV 100 kHz repetition frequency 3V 0 15MHz 80MHz 6V in ISM and amateur radio bands b...

Страница 18: ...0 UT 1 cycle 70 UT 25 30 cycles Single phase at 0 o 0 UT 250 300 cycles 0 UT 0 5 cycle a At 0 o 45 o 90 o 135 o 180 o 225 o 270 o and 315 o 0 UT 1 cycle 70 UT 25 30 cycles Single phase at 0 o 0 UT 250...

Страница 19: ...00 385 450 710 704 787 430 470 380 390 1 8 2 2 2 2 0 2 0 2 0 3 0 3 0 3 0 3 0 3 0 3 0 3 27 27 28 28 28 28 28 28 28 28 9 9 9 9 800 960 1700 1990 2400 2570 5100 5800 810 1720 5240 745 870 1845 5500 780 9...

Страница 20: ...YA is a registered trademark owned by Aura Medical LLC All rights reserved Engineered and designed in the USA by Aura Medical LLC Assembled in China For support or Inquires support aura medical com ww...

Отзывы: