background image

 5 

Programming example

 

Select a product family

Select ‘Select Product’

Select a product

Select the programming subset

Scroll up or down to select the parameter to change

Change the value as required.

Press ‘Send’ to send parameter value to device.

If more than one parameter has been changed. Press ‘Send’ for 2 seconds and all the parameters in the current
menu will be sent, including those that have not been modified

STANDALONE  
 Select  Product 

 

 > 

SELECT  PRODUCT  
 PRM 

 

 > 

 DD 

 

 > 

 AD 

 

  

DD 
 Detector  Params 

 

 > 

 Output  Ch.  1 

 

  

 Output  Ch.  2 

 

  

DETECTOR  PARAMS  
 Walk Test LED 

Off 

 Time Out  (mins)    

20 

 Manual  Time  Out   

10 

DETECTOR  PARAMS  
 Walk Test LED 

Off 

 Time Out  (mins)    

15 

 Manual  Time  Out   

10 

All parameters specified in the individual Product Guides can be programmed using this handset. Refer to the product 
guides for information on the default values and details on the parameters. The ‘Help’ function on this handset gives an 
overview of the parameter function. 

PRODUCT FAMILY  
 Standalone 

 

 > 

 An- 10 

 

 > 

D- Mate

 

  

Programming a battery-powered An-10 device 

Battery-powered An-10 devices must be set into a receive mode before they can be programmed.

This is achieved by pressing the Config Button on the device.  The device’s LED indicator will then blink red to
show it is in receive mode.

The device will return to sleep mode if it does not  receive any commands within 30 seconds.

Permanently powered devices are always ready to receive the infrared signals provided by the handset.

Note 

Please refer to the target device’s instruction leaflet for the location of its Config Button.

 

Содержание UNLCDHS

Страница 1: ...to a device by pressing the send button This Product Guide relates to software version 1 10 Universal LCD programming handset UNLCDHS Product Guide 12345678901234567890 12345678901234567890 12345678901234567890 12345678901234567890 Features Belt clip IR transmitter IR Transmitter LEDs Sends IR code to a device IR Receiver Receives IR code from a device for reading back parameters or determining th...

Страница 2: ...uct family some parameters may not be available for all products within a family Select the parameter group to program Detector param for example Entering parameter values Select the item with up down buttons Timeout for example and keys Use to make small adjustments or for On Off Yes No parameters Using the number keys When you type a number it adds it on to the right and scrolls the digits left ...

Страница 3: ...e Turns the device on off Help Displays the help screen further explanation for the selected item Press help again to cancel None Shows software version number Home Goes back to the root menu for the currently selected product range Goes back to the main root menu R Read Reads back the currently selected parameter Reads back all the selected parameters in the active menu only S Send Sends the curr...

Страница 4: ...efault is 10 Range 1 99 Repeat Send rate When Send is held down eg for Lux up it is the interval between IR messages milliseconds Default is 22 Range 1 99 Mute Disables all sounds Default is No To Bootloader Resets the handset Used for updating the software see Updating UNLCDHS software section of this document To view Bootloader and Software versions select To Bootloader then turn handset on The ...

Страница 5: ...s specified in the individual Product Guides can be programmed using this handset Refer to the product guides for information on the default values and details on the parameters The Help function on this handset gives an overview of the parameter function PRODUCT FAMILY Standalone An 10 D Mate Programming a battery powered An 10 device Battery powered An 10 devices must be set into a receive mode ...

Страница 6: ...ed as a group that can be sent to a device DETECTOR PARAMS Time Out mins 20 Manual Time Out 10 Sensitivity On 9 DETECTOR PARAMS Time Out mins 15 Manual Time Out 10 Sensitivity On 9 DETECTOR PARAMS Time Out mins 15 Manual Time Out 10 Sensitivity On 4 MACRO REVIEW Time Out mins 15 Sensitivity On 4 Switch Only Creating a Macro Saving a Macro At the Macro Review stage press Record Enter a name for the...

Страница 7: ...t the parameter to be read from a unit Direct the handset towards device and press the Read button The handset will click when the parameter has been read back the device will flash its LED and the value will be shown against the parameter in the menu This can then be edited if necessary Point the unit at a device and press the Send button This will then send the setting To read back all of the pa...

Страница 8: ... EMC 2004 108 EC Technical data Care and maintenance Replacing the Batteries The battery compartment is located at the rear of the handset Press and slide the battery compartment door see opposite Lift out the batteries from the holders and insert a replacement batteries AAA type ensuring correct polarity Slide the door back into the handset ensuring that it clips in place Cleaning the Handset The...

Отзывы: