22
Assembly Instruction
KS 4 S12 24V DC R
07
C
ABLE
ROUTING
:
ON
THE
CASEMENT
OR
FRAME
NSK
HSK
I
NSTALLATION
STEP
7:
C
ABLE
ROUTING
Cable routing on the frame
FL
AK
RA
RA
KS4
KS4
K134
Route cable on the frame or mullion/transom.
Cable must be protected against damage (shearing-off,
kinking,
splitting).
cable duct glued on
(in addition secured with
countersunk screws against
breaking away)
Cable on casement
Cable in glazing bead
Connection cable routing on the casement:
• Cable must be protected against damage (shearing-off, kinking,
splitting), i.e. by using bushings.
Upon removal of the glazing bead is the dan-
ger that the glass may fall.
!
Cable routing on or in the casement
Cable crossover without
protective cable hose
Cable crossover with
protective cable hose
Connection cable routing on the hinge side:
• Make sure that during opening or closing procedure the cable will
not be damaged by shearing-off, kinking, crushing.
• Protect cable feedthrough in profi le e.g. by using cable bushings,
cable transitions.
RA
RA
FL
BD
protective cable
hose
BD
AK
FL
RA
RA
FL
FL
Cable duct glued on
(in addition secured with
countersunk screws against
breaking away).
Drill hole in glazing bead
(cable bushing protects against
damage to cable).
07