GENERATOR

 

PROTECTION RELAY 

 

 

 

 

GENERATOR  PROTECTION  RELAY  (MG30  &  MG30-I);

 

These  are

 

Multifunction  Microprocessor  Relay  for 

protection of medium/ large synchronous generators. The relay measures the RMS of three-phase currents and voltages and 

computes  the  positive  and  negative  sequence  components  of  the  Current  system.  A  separate  input  is  dedicated  to  the 

measurement  of  the  Neutral-to-Ground  voltage  and  its  harmonic  components  used  for  a  complete  Stator  Ground  Fault 

protection. MG30 incorporates 5 output relays expandable up to 16 with the additional module REX-8. 

 

 
Features;

 

 

Voltage-controlled over-current protection. 

 

Thermal image element with pre-alarm level. 

 

Reverse power protection. 

 

Loss of Field protection. 

 

PT s' fuse failure protection    

 

Modbus Communication Protocol  

 

Breaker Failure protection 

 

Inadvertent C/B closure protection 

 

Blocking Output and Blocking Input for pilot wire selectivity coordination. 

GENERATOR PROTECTION RELAY (MG30 & MG30-I)

 

Item 

Generator Protection Relay  

Make 

L&T 

Model 

MG30 & MG30-I 

Generator Type 

MG30:

 For Impedance Grounded (NGR / NGT) 

Generators.                                                                                    

Applications 

MG30 / is Multifunction Microprocessor Relay for 
protection of medium/large synchronous 
generators. The relay measures the RMS of three-
phase currents and voltages and computes the 

positive and negative sequence components of the 
Current system. 

Содержание MC 12A

Страница 1: ...b stations The relay has a built in high set facility DIP switches are provided on the front panel for pick up and time delay settings User has a choice of 7 trip time characteristics FEEDER PROTECTIO...

Страница 2: ...1987 a Normal Inverse 3s b Normal Inverse 1 3s c Very Inverse d Extremely Inverse Definite time Three curves as follows e Definite Time 1s f Definite time 10s g Definite time 100s Accuracy As per Erro...

Страница 3: ...iliary Supply 24 240 V AC DC Wide TMS Range 0 01 1 60 Draw out execution With automatic CT shorting facility Instantaneous Over current and earth fault element Communication Through Modbus Protocol on...

Страница 4: ...Stator Ground Fault protection MG30 incorporates 5 output relays expandable up to 16 with the additional module REX 8 Features Voltage controlled over current protection Thermal image element with pr...

Страница 5: ...Instantaneous output 30ms 2 Harmonic restraint level 2H 0 1 1 0 Id step 0 01Id First percent bias 0 5 IR In P 1R 2 20 step 1 Second percent bias IR In P 2R 5 50 step 1 Point of slope variation P 1 3 s...

Страница 6: ...0 to 40 of In in steps of 5 or 20 to 80 of In in steps of 10 CT Burden Less than 1 0 VA at Is min Less than 6 VA at Is max Operating Characteristics Front panel programmable using push buttons Pick up...

Страница 7: ...se Cts 1 9999 A step 1A On Rated primary current of earth fault detection Cts 1 9999 A step 1A CT Burden Less than 1 0 VA at Is min Less than 6 VA at Is max Operating Characteristics Front panel progr...

Страница 8: ...utomatically manage the starting transition Switch over transition current Itr 0 1 1 Ist step 0 1Ist Maximum switch over time delay tTr 0 5 50 s step 0 1s At motor s start counting of tTr begins If du...

Страница 9: ...pick up level A DIP switch is provided for selection of thermal overload trip class and enable disable of Locked rotor protection and under current protection Other settings are prefixed in the relay...

Страница 10: ...3 sec Both factory set Locked rotor protection Locked rotor current 3 Im Trip time delay 1 sec Both factory set Disable feature Available Under Current protection Under current threshold 50 of Im Tri...

Страница 11: ...d applicable time delays are indicated on a label on right hand side of the unit The wiring diagram label is provided on the left hand side of the unit Display Current and Thermal Capacity Display Dur...

Страница 12: ...l through various settings Function LED showing number or alphabet to indicate which setting is being view as shown in Figure 3 Table 1 gives description of each setting APPLICATIONS MPR 300 offers yo...

Страница 13: ...dVB IdVC Maximum Demand and Inrush Recording IdA IdB IdC Ido I1A I1B I1C I2A I2B I2C IdIIA IdIIB IdIIC IdVA IdVB IdVC Programmable Input Quantities Fn System frequency 50 60 Hz 1In Rated primary curre...

Страница 14: ...1In Detection time 6ms t 20ms Peak current detection with DC offset restraint Digital Inputs B1 Operation block input B2 Harmonic restraint s reduction B3 Oscillographic record external trigger Approv...

Страница 15: ...00 ms can be set Current Input 1A 5A Application These relay can be used for differential protection of generators REF applications of generators and transformers in all low voltage medium voltage sub...

Страница 16: ...nt Function enabling Enable Disable Setting range V 0 5 1 50 Vn step 0 01Vn Instantaneous output 0 03s Trip time delay tV 0 05 60 s step 0 01s F59 V Second OverVoltage Element Function enabling Enable...

Страница 17: ...alanced Overvoltage Element Function enabling Enable Disable Setting range V2 0 1 1 5 Vn step 0 01Vn Instantaneous output 0 03s Trip time delay tV2 0 05 60 s step 0 01s Characteristics Accuracy at ref...

Страница 18: ...t Characteristics Normal Inverse 3 5 sec in O V mode Normal Inverse 5 7 sec in U V mode Definite Time 1 10 100 Sec Pick up Voltage Same as set Voltage Vs Reset Voltage 90 to 95 of Set Voltage Vs 105 t...

Отзывы: