AUMA SBA 12 Скачать руководство пользователя страница 5

AUMA Industry & Marine GmbH, 08.2018 

MON_SBA06-200_DE_EN_rev01.docx  

Seite/page 5/8 

1. Safety 

instructions 

1.1 Basic 

safety 

requirements 

The end user or the contractor must ensure that all legal requirements, directives, guidelines, national regulations and 
recommendations with respect to assembly, electrical connection, commissioning and operation are met at the place of 
installation. 
The end user or the contractor are responsible for implementing required protective measures on site, such as 
enclosures, barriers, or personal protective equipment for the staff. 
All personnel working with this device must be familiar with the safety and warning instructions in this manual and 
observe the instructions given. Safety instructions and warning signs on the device must be observed to avoid personal 
injury or property damage. 
Prior to working on this product, the staff must have thoroughly read and understood these instructions and, 
furthermore, know and observe officially recognised rules regarding occupational health and safety. 
Assembly, electrical connection, commissioning, operation, and maintenance must be carried out exclusively by 
suitably qualified personnel having been authorised by the end user or contractor of the plant only. 
Prerequisites for safe and smooth operation: 

  Correct transport, proper storage, mounting and installation, as well as careful commissioning. 

  Only operate the device if it is in perfect condition while observing these instructions. 

  Immediately report any faults and damage and allow for corrective measures. 

  Observe recognised rules for occupational health and safety. 

  Observe the national regulations. 

  During operation, the housing as well as internal parts warm up and surface temperatures > 60 °C may occur. To 

prevent possible burns, we recommend to the check surface temperature with an appropriate thermometer prior to 
working with device and to wear protective gloves, if required. 

 

1.2 

Explanation of the safety symbols 

This sign means: 

DANGER! 

In case of non-observance lethal danger can exist respectively severe physical injuries and/or essential material 
damages can occur.  
This sign means: 

HINT! 

The hint marks technical relationships, to which it is especially pointed out. In case of non-observance there can occur 
deficient functions, operating disturbances and perhaps consequential damages. 

2. 

Transport, storage and packaging 

Concerning transport and storage of the linear actuator the following is to be observed: 

  The transport to the place of installation must be effected in a firm packing 

  If the linear actuator is built on valve, the hoist must not be fixed on the actuator 

  Store the actuator in a well aerated and dry room 

  Protect the actuator against humidity of the soil by storing it in a shelf or on a wooden grid 

  Fix a sheathing to protect against dust and filth etc. 

 
Danger of corrosion in case of inappropriate storage! 

3. Technical 

description 

3.1 Identification 

Each actuator has a name plate, which provides information about the maximum operation conditions and has a unique 
serial number (F.-Nr.).  

3.2 Technical 

data 

Please refer to the technical data sheets 

3.3 Service 

conditions 

In case of strongly oscillating ambient temperatures and high air humidity the installation of a heating resistor is 
recommendable in order to minimize the formation of condensate in the actuator.  
Actuator coverage with suppressed cold bridges (double hoods) are recommended.  

  Connect heater HZ according to terminal plan. 

  After mounting, immediately put device into operation. 

 
The actuators are suitable for installation in industrial units, in water or power plants with a low pollutant concentration.  
In the open, respectively an environment having high pollutant concentrations, e.g. areas having a high traffic rate, 
industrial areas (chemical plants, sewage works, etc.) coastal regions and open sea, the actuators must additionally be 
provided with external blinds of non-corrosive material and also with a special lacquering.  
In open air the linear actuator can be protected with an additional coverage against 

 rain 

 direct 

insolation 

 
 
 

Содержание SBA 12

Страница 1: ...areas or radiation exposed areas in nuclear power plants is not designated Inhalt 1 Sicherheitshinweise 2 1 1 Grundlegende Sicherheitsanforderungen 2 1 2 Erl uterung der Sicherheitssymbole 2 2 Transpo...

Страница 2: ...chen bedeutet GEFAHR Bei Nichtbeachtung kann Lebensgefahr bestehen bzw k nnen schwere K rperverletzungen und oder erhebliche Sachsch den auftreten Dieses Zeichen bedeutet HINWEIS Der Hinweis markiert...

Страница 3: ...el heben und auf das Ventiloberteil oder auf die Ventillaterne setzen Kupplung gem Bild 4 2 1 zusammensetzen Kontermutter auf Ventilspindel drehen Sicherungsblech 61 und Verdrehsicherung 60 ber Ventil...

Страница 4: ...erlastung kann es zu schwerwiegende Sch den an der Armatur kommen Achten Sie bei Montage und Justierung auf sich bewegende Teile Es besteht Verletzungsgefahr und Gefahr von erheblichen Sachsch den 6 1...

Страница 5: ...of the safety symbols This sign means DANGER In case of non observance lethal danger can exist respectively severe physical injuries and or essential material damages can occur This sign means HINT Th...

Страница 6: ...screws 66 Lift the actuator over the valve stem and put it onto the bonnet or yoke of valve Assemble the coupling according to figure 4 2 1 Screw counter nut onto the valve stem Lay the locking plate...

Страница 7: ...data Overstressing can cause serious damage to the valve Pay attention to moving parts during the mounting and adjustment There exists the danger of being injured and the risk of essential material da...

Страница 8: ...eration of industrial valves Putting into service is prohibited until the final machinery has been declared in conformity with the provisions of Directive 2006 42 EC The following basic requirements i...

Отзывы: