ADJUSTING THE CCR
II.3.1 ADAPTATION TO LOAD
Adjusting the CCR output power to that installed, using the load plate : This can be done by moving the
load setting straps between 1/8 and 8/8. For example, if the load is equivalent to 60% of the rated power of the
CCR, the setting is to the nearest value above, i.e. 5/8 = 62.5%.
If the load power is not known, set the load plate straps to 8/8.
L
See paragraph I.6.1 for a description of the load plate, and how to enter the modifications in memory.
II.3.1.1 Maximum power levels by power settings:
The maximum power levels (in Kva, or in KW on a resistive load) allowed for each power setting, according to
the rated power of the CCR are as follows:
Charge adaptation setting
Rated
power
1/8 2/8 3/8 4/8 5/8 6/8 7/8 8/8
2.5 kVA
< 0.32 < 0.63 < 0.94 < 1.25 < 1.57 < 1.88 < 2.19 < 2.50
5 kVA
< 0.63 < 1.25 < 1.88 < 2.50 < 3.13 < 3.75 < 4.38 < 5.00
7.5 kVA
< 0.94 < 1.87 < 2.81 < 3.75 < 4.69 < 5.63 < 6.56 < 7.50
10 kVA
< 1.25 < 2.50 < 3.75 < 5.00 < 6.25 < 7.50 < 8.75 < 10.0
15 kVA
< 1.88 < 3.75 < 5.63 < 7.50 < 9.38 < 11.3 < 13.2 < 15.0
20 kVA
< 2.50 < 5.00 < 7.50 < 10.0 < 12.5 < 15.0 < 17.5 < 20.0
25 kVA
< 3.13 < 6.25 < 9.38 < 12.5 < 15.7 < 18.8 < 21.9 < 25.0
30 kVA
< 3.75 < 7.50 < 11.3 < 15.0 < 18.8 < 22.5 < 26.3 < 30.0
II.3.2 PARAMETER MODIFICATION
Preferably, and according to the CCR, the parameters are pre-set in the factory as ordered, so it is not
necessary to reconfigure them during device installation and commissioning.
II.3.2.1 Preferred configuration values:
The preferred configuration (if no precision on orders, or in case of new mother board) is as follow :
•
Setting
I B0 = 1.50 A
I B1 = 2.80 A
I B2 = 3.40 A
I B3 = 4.10 A
I B4 = 5.20 A
I B5 = 6.60 A
Brightness number = 6
Maxi current = Setting value +3%
Mini current = Setting value -3%