AUGIER Energy DIAM 3100 Скачать руководство пользователя страница 4

 

 

6021752 DIAMXXXX CUT OUT rev 1-0.doc 

I-4 

WARRANTIES 

 
 

Guarantee 

 
AUGIER’s  goods has been manufactured and will perform in accordance with applicable specifications, 
and  any  defect  in  design,  materials  or  workmanship  which  may  occur  during  proper  and  normal  use 
during  a  period  of  1  year  from  date of  installation  or  2  years  from  date of shipment  will  be  corrected  by 
repair or replacement by the manufacturers f.o.b factory. 
 
The    guarantee  covers    repair,  modification  or  replacement  of  parts  or    products  recognised  to  be 
defective,  in the  shortest possible time, at AUGIER’s cost, provided always that the goods have been 
properly handled and stored prior installation, properly installed and properly operated after installation. 
 
Unless otherwise specifically  laid down  in contract, the guarantee does not cover: 

 

Costs of consignment to factory and re-consignment of defective goods to  Buyer  

 

Travelling  &  sojourn  expenses  of  AUGIER’s  personnel  if  goods  have  to  be  repaired  on  site; 

assembly and dismantling of any goods other than those recognised to be defective; expenses incurred 
for waiting times by AUGIER’s personnel on site for reasons independent of their will;  

 

Unjustified travel expenses. 

 
Guarantee shall  not apply in the following cases: 

 

Defects in materials supplied by Buyer or due to  any designs imposed by them; 

 

Repairs or replacements  due to normal wear and tear,  or damages or accidents. 

 

Repairs or replacements due to damages or accidents resulting from negligence or lack of due care, 

inadequate supervision or maintenance, or erroneous use of the equipment or software;  

 

Any  other  causes  for  which  AUGIER  shall  not  be  held    responsible,  e.g.  resulting  from  an  case  of  

Force Majeure. 

 

When Buyer has replaced A

UGIER’s  parts with other parts. 

 
Buyer  must  inform    AUGIER  in  writing  and    without  delay  of  any  defects  in  goods,  giving  all  necessary 
information and  detailed description of  how equipment has been utilised, together with  purchase date.   
Buyer  undertakes  not  to  have  repairs  carried  out  by  third  parties;  any  repairs  carried  out  without 
AUGIER’s express prior  agreement shall  invalidate the guarantee. 
 
It  is  expressly  agreed  between  the  two  parties  that  Buyer  cannot  avail  himself  of  the  beneficial 
dispositions  contained  in  the  guarantee  without  having  first  satisfied  payment  conditions  laid  down  in 
contract 
 
 

Disclaimers 

 
This manual could contain technical or typographical errors. AUGIER reserves the right to make changes 
and  revise  this  manual  from  time  to time  without  obligation  to  notify  any  person  or  organisation  of  such 
changes or revision. 
Values  and  measurements  given  in  this  manual  are  average  values  and  are  not  binding.  AUGIER 
disclaims any liability for damages suffered as a result of reliance on the information given in this manual, 
or the use of equipment or processes which this manual refers. 
No  guarantee  is  made  that  the  use  of  the  products,  equipment,  processes  or  information  to  which  this 
manual  refers  will  not  infringe  any  third  party’s  patent  or  rights.  Information  given  does  not  release  the 
buyer from making their own tests. 
 

Содержание DIAM 3100

Страница 1: ...051 6656 677 ocem ocem com www ocem com VAT Nr IT 031 4821 1208 a division of Energy Technology srl Compliance with standards ICAO Aerodrom design manual part 5 IEC 61822 et 61821 FAA AC 150 5345 10F...

Страница 2: ...6021752 DIAMXXXX CUT OUT rev 1 0 doc I 2...

Страница 3: ...6021752 DIAMXXXX CUT OUT rev 1 0 doc I 3 RECORD OF CHANGES Rev Pages Description From S N By App Date 1 0 First issue ED ED 31 01 19...

Страница 4: ...s or accidents resulting from negligence or lack of due care inadequate supervision or maintenance or erroneous use of the equipment or software Any other causes for which AUGIER shall not be held res...

Страница 5: ...and maintenance personnel should familiarise and keep themselves trained with resuscitation techniques found in widely published manuals about first aid instructions ELECTROSTATIC DISCHARGE ESD Elect...

Страница 6: ..._____________________ II 16 II 3 1 SERVICE POSITION ________________________________________________________II 16 II 3 1 1 SAFETY POSITION _____________________________________________________II 16 II...

Страница 7: ...____________________________________________________ II 25 II 6 4 MA SWITCH _______________________________________________________________ II 25 II 6 5 MB SWITCH _____________________________________...

Страница 8: ...reviation Definition A Ampere AC Alternating Current B Brightness CCR Constant Current Regulator DC Direct Current EFD Earth Fault Detector HV High Voltage IT Injection Transformer LFD Lamp Fault Dete...

Страница 9: ...6021752 DIAMXXXX CUT OUT rev 1 0 doc I 9...

Страница 10: ...The main function is to connect easily the loop to the earth A second function is to measure the impedance loop 6 models CCR code CBA SIMALT Type 1 SIMALT Type 2 SIMALT Type 3 CCR code CSE CCR code CR...

Страница 11: ...ERVICE MAINTENANCE or SAFETY MEASUREMENT See Note 1 Note 1 No measurement position for SEB cut cout Standards ICAO Airport design manual part 5 STNA CCTP 91068 rev 93 CENELEC prENV 50231 FAA AC150 534...

Страница 12: ...ition vertically the loop s terminals are linked to the output of the CCR II 1 2 1 SAFETY POSITION By removing the two jumpers from the previous operating position as above the CCR will be disconnecte...

Страница 13: ...concerning the load This is the measurement position of the cut out plate WARNING Although the CCR and the loop are isolated the CCR can be switched ON In the case where the two jumpers are removed it...

Страница 14: ...onal position jumpers In horizontal position II 2 2 SAFETY POSITION By removing the two jumpers from the previous operating position as above the CCR will be disconnected from the loop in a safe and c...

Страница 15: ...ev 1 0 doc II 15 II 2 1 LOAD MEASUREMENT POSITION By removing the two jumpers of L1 L2 it is possible to measure the load WARNING The CCR can start in short circuit and voltage can appear on the CCR o...

Страница 16: ...position jumpers In horizontal position II 3 1 1 SAFETY POSITION By removing the two jumpers from the previous operating position as above the CCR will be disconnected from the loop in a safe and cle...

Страница 17: ...r to allow to proceed at all insulation and continuity measurements which can be carried out as well as any other testing or research operations concerning the load This is the measurement position of...

Страница 18: ...interlock contact may be provided in order to shunt down the CCR while manoeuvering the handles or monitor its position II 4 2 SERVICE POSITION It is the operational position The handle is plugged in...

Страница 19: ...ided in order to prevent any access to live parts during energised CCR operation while setting the position switch WARNING The loop is NOT CONNECTED TO EARTH If the interlock switch is installed and w...

Страница 20: ...N This safety position will allow the operator to work on the load safely the load is in short circuit and grounded The CCR cannot be energised II 5 4 LOAD MEASUREMENT POSITION This measurement positi...

Страница 21: ...are accessible in direct way on the front panel without opening the CCR II 5 7 CIMALT MAINTENANCE 1 Remove the 3 fixing screws and tilt the support plate forward to access the back of the switch 2 Che...

Страница 22: ...6021752 DIAMXXXX CUT OUT rev 1 0 doc II 22...

Страница 23: ...ews and remove the 2nd stage assembly to perform the same check on the first stage of the switch 4 Former equipment THO DIAMANT CCRs and switches mounted on Epoxy plate verification must be done from...

Страница 24: ...6 1 DESCRIPTION DIAM4100 fitted with OCEM cut out 3 positions of the cut out Normal maintenance loop measurement II 6 2 OVERVIEW Positions and functions The switch MA and MB connected to the CCR elect...

Страница 25: ...n the switch is open Loop measurement position or cut out removed the CCR can t start and the following message appears In french In english In spanish When the switch is closed Normal position mainte...

Страница 26: ...low the operator to work on the load safely the load is in short circuit and grounded The CCR output is in short circuit It can be energised The rotative switch may be locked in the safety position II...

Страница 27: ...gnation Code SIMALT 1 Cut out earthing plate Jumper 30 09323 30 09325 SIMALT 2 Cut out earthing plate Jumper 30 11851 10 25705 SIMALT 3 Jumper 30 07967 SEB Red handle service handle Green handle 30 11...

Страница 28: ...srl Operating office Via della Solidarieta 2 1 40056 Valsamoggia Loc Crespellano BO Italy Ph 39 051 6656 611 Fax 39 051 6656 677 ocem ocem com www ocem com VAT Nr IT 031 4821 1208 a division of Energ...

Отзывы: