EUROPE: +44 (0) 1451 861 562 AUSTRALIA: +61 (0) 7 3274 2077 USA: (+1) 844 287 6300
2
2
56Nm/41ft-lb
1
/
2
” BSP
56Nm/41ft-lb
1
/
2
” BSP
2
2
HYDRAULIC CONNECTIONS
All Auger Torque Sweeper Units require a ‘flow’ and ‘return’ of hydraulic fluid from the parent machine’s
auxiliary hydraulic power supply to operate. All Sweepers are reversible and require the host machine to be
fitted with a two way flow auxiliary circuit. Check with the parent machine dealer for advice.
When fitting hydraulic hoses, ensure that they are tightened to the correct torque for the hose fittings.
Some models of Sweeper are supplied with hydraulic quick release couplers, which are required for
connection to the parent machine.
The parent machine auxiliary hydraulic connections are normally located near the end of the loader arms
The motor and bearing assemblies on the Sweeper unit can be changed over from right to left so that the
motor hoses are postioned near the auxiliary hydraulic connections on the parent machine (see operators
manual for full instructions).
Ensure that the hydraulic pipes are of sufficient length to allow the sweeper to move freely during work.
It is critical that the supply of oil is within the stated limits for the particular Sweeper unit. Check that the
rated flow (l/min - gal/min) & pressure (Bar - PSI) of your machine does not exceed the limits shown on the
serial plate.
Motor mounted on left
Motor mounted on right