Call Through with Password 

In order to avoid a malicious use by unauthorized callers, the function Private Exchange Line Access (if
supported by the PBX) can be used. Then the caller must enter a password before entering an external
telephone number (e.g. „password 0 05306 9200700“).

Configure the exchange line authorization for the analog extension connected with the socket „ATA“ in
a manner that external calls are only possible with Private Exchange Line Access (when entering a pri-
vate password: see manual of the PBX).

Normally the Private Exchange Line Access is started with entering of some special digits (e.g. „90“ for
some Auerswald PBX systems), afterwards the private password can be entered. Enter these special
digits as pre-configured destination number into the Auerswald Box as described in the following:

When entering the telephone number the signs 

*

 and # are also possible. If you wait at least 5 seconds

during the dialing, you will hear a confirmation tone as a signal that a pause has been saved.

If a Call Through to internal telephones should still be possible, do not enter the exchange line access
digits into the Auerswald Box. Then the caller has to dial the exchange line access digits and to enter
the password before dialing an external telephone number (e.g. „90 password 0 05306 9200700“).

Important Information on Call Through with Auerswald Box 

Please note that via the Auerswald Box a modification of the settings of the PBX are possible, too. Do
not enable any programming authorization for the extension connected with the jack „ATA“ of the

Auerswald Box or protect the PBX by passwords to prevent unauthorized interventions.

Configure (if supported by the PBX) LCR (Least Cost Routing) for the internal extension of the Auerswald
Box to save money (see manual of the PBX).

Each internal subscriber can start outgoing external calls with the Auerswald Box. In this case a restriction
by authorizations or number restrictions (e.g. 0900, 0190, 0180) is not possible. 

e

Attention: Please check if the PBX generates a busy tone on the port connected to the jack „PBX/

Tk-Anlage“ on call completion (may be a configuration option in the PBX). Connections are not

terminated otherwise.

e

Attention: Unauthorized persons may use your PBX to dial through to an external telephone
number and make calls at your cost if they know the special external telephone number (Call
Through number). Please absolutely pay attention on the following security advice:

The length of the call should be limited. In the default factory settings the Auerswald Box only permits a
maximum call duration of 60 minutes. How it can be changed is described in the chapter “Configure the
maximum Call Duration” on 
page 10.

Configure a number restriction (e.g. 0900, 0190, 0180) for the internal extension of the Auerswald Box
labeled wit „ATA“ (if supported by the PBX: see manual of the PBX) to prevent the dialing of these tele-
phone numbers.

In order to avoid a malicious use by unauthorized callers, the function Private Exchange Line Access (if
supported by the PBX) can be used. How to configure it is described in the chapter “Call Through with
Password” on 
this page.

Additional general advice of programming and telephoning with the Auerswald Box can be found on page
10.

N

1

e. g

 

90

press the programming 

key on the Auerswald 
Box for at least 3 sec-

onds until the LED 

nearby flashes 

pick up the receiver 

of any available 

internal telephone 

dial the telephone 

number of the inter-

nal   extension of 

the Auerswald Box 

(e.g. 34)

wait for the 

end of the 

confirma-

tion tone 

dial „1“

dial digits for 

Private Exchange 

Line Access

hang up

Содержание Box

Страница 1: ...Default Factory Settings 11 Drilling Template 12 F Features 2 G General Advice 10 I Important Information Call Through 8 Internet Telephony 6 two PBX systems 10 Internet Calls 3 Internet Telephony 2 L LED Signalization 11 M Maximum Call Duration 10 O Operation Call Through 7 Internet Telephony 3 two PBX systems 9 R Requirements Call Through 7 Internet Telephony 3 S Scope of Delivery 11 T Technical...

Страница 2: ...og or ISDN cable connection The digital voice data is sent as IP packets from one telephone to the other partner This works like the transfer of a homepage from the Internet There are already numerous providers who do not only allow to make outgoing calls but also offer an individual telephone number for each customer With this telephone number you can also telephone into the fixed network and sta...

Страница 3: ... or SIP provider Outgoing Internet Calls with the Auerswald Box To start a call via the Internet the Auerswald Box can be called by each internal subscriber of the PBX As soon as the Auerswald Box establishes the connection to the ATA dial tone the telephone number to be dialed in the Internet can be entered by DTMF Incoming Internet Calls with the Auerswald Box There are different operation modes...

Страница 4: ...h the ATA If the caller does nothing the PBX will dial a pre configured internal or external telephone number Like in the operation mode C the PBX can be used for dialing through to an external telephone number in the fixed network or to the mobile telephone network The advantage over operation mode C is The caller will always be connected even if he has no knowledge about the internal telephone n...

Страница 5: ...ary in the Auerswald Box If the Auerswald Box does not have the default factory settings concerning call acception immediate and destination number empty you can reset it as described in the chapter Reset to Default Factory Settings on page 11 N 1 N press the programming key on the Auerswald Box for at least 3 seconds until the LED nearby flashes pick up the receiver of any available inter nal tel...

Страница 6: ...rmits a maximum call duration of 60 minutes How it can be changed is described in the chapter Configure the maximum Call Duration on page 10 Configure a number restriction e g 0900 for the internal extension of the Auerswald Box if supported by the PBX see manual of the PBX to prevent the dialing of these telephone numbers Configure if supported by the PBX LCR Least Cost Routing for the internal e...

Страница 7: ...se all functions that are possible on this extension Therefore assign the authorizations correspondingly Do not configure any external telephone number for this extension For Call Through there are no settings necessary in the Auerswald Box If the Auerswald Box does not have the default factory settings anymore concerning call acception immediate and destination number empty you can reset it as de...

Страница 8: ...t Routing for the internal extension of the Auerswald Box to save money see manual of the PBX Each internal subscriber can start outgoing external calls with the Auerswald Box In this case a restriction by authorizations or number restrictions e g 0900 0190 0180 is not possible e Attention Please check if the PBX generates a busy tone on the port connected to the jack PBX Tk Anlage on call complet...

Страница 9: ...n of two PBX systems no settings are necessary in the Auerswald Box If the Auerswald Box does not contain the default factory settings concerning call acception immediate and destination number empty you can reset it as described in the chapter Reset to Default Factory Settings on page11 Consult the corresponding manuals of the other devices during installation The range of Auerswald Box and PBX m...

Страница 10: ... access number e g 0 the Auerswald Box cannot be reached for the next 2 minutes In the default factory settings the Auerswald Box only allows a maximum call duration of 60 minutes for incoming and outgoing calls due to safety reasons How to change it or to disable the restriction is described in the following in the chapter Configure the maximum Call Duration Configure the maximum Call Duration In...

Страница 11: ...e blue semitransparent 2 pieces Dimensions 얒 95 x 33 mm Weight app 90 g Safety CE Temperature 0 to 40 C of environment Layout of Western modular jacks Scope of Delivery 앫 1 device Auerswald Box 앫 2 connection cables RJ 11 on RJ 11 앫 User manual 앫 Guarantee flyer 앫 Mounting Material 2 screws and 2 dowels Wall Mounting The device is also made for wall mounting Drill two wholes with a diameter of 6 m...

Страница 12: ...12 Drilling Template ...

Отзывы: