Technical Specifications

Connection data at X1 01
Power supply 

Power over Ethernet according to IEEE 802.3af

Voltage POE 

48 VDC (min. 44 V, max. 61  V)

Power consumption 

3.5 W

Display 

1 28 x 64 pixels

Ringing sound pressure level 

max. approx. 95 dB (A) at 1  m

Housing (height x width x depth) 

293 x 1 91  x 1 28

Weight 

approx. 2,300 g

Operating position 

Table or vertical wall mounting

Receiver

Microphone 

Electret-foil microphone

Receiver inset 

Dynamic receiver inset with magnetic field generator

Connection X1 01  

(1 0/1 00 Mbit/s) LAN cable with 8 conductors 

AWG 22 to 24 for solid conductors, or 

AWG 24 for multi-wired conductors

Dimensions Connecting cable / Cable entry
Cable glands 

M20 x 1 ,5 
In case of factory fitted cable glands the attached 

operating instructions have to be considered.

Blind plugs 

M20 x 1 ,5 / M1 2 x 1 ,5

Connection potential compensation  1 ,5 – 4 mm

2

Ambient temperature range  
Operating ambient temperature range  -20°C 

 Ta 

 +55°C

Storage and transport temperature 

-25°C 

 Ta 

 +70°C

Housing degree of protection 

IP65

L abelling
Company

Auer Signal GmbH

Type 

dFT3-IP
AUER 16 ATEX 0002

CE 01 58

II 3G Ex nA ic IIC T5 Gc

II 3D Ex tc ic IIIC T80°C Dc

-20°C 

 Ta 

 +55°C 

IP65  U

m

= 61  VDC; U

n

= 48 VDC

Содержание dFT3-IP

Страница 1: ...Flameproof version of the weatherproof telephone wFT3 IP Operating instruction dFT3 IP 1 0 E dFT3 IP ...

Страница 2: ... dFT3 IP and guide the LAN cable through the cable gland item 4 on the lower side of the telephone and secure the cable using the cable gland The dFT3 IP delivery includes a bag with a connector socket with a cut andclamp device for connecting the LAN cable with the short 8 pin cable piece within the telephone Follow the instructions on the bag for shortening and placing the individual conductors ...

Страница 3: ...garding possible damage or positioning If the seals are damaged operating the telephone is not allowed Damaged seals must be replaced Disposal The complete device should be disposed of as electronic waste When the device is disas sembled plastics metals and electronics components are to be disposed of separately In every single case the national requirements and regulations for waste disposal must...

Страница 4: ...onnection X1 01 1 0 1 00 Mbit s LAN cable with 8 conductors AWG 22 to 24 for solid conductors or AWG 24 for multi wired conductors Dimensions Connecting cable Cable entry Cable glands M20 x 1 5 In case of factoryfitted cable glands the attached operating instructions have to be considered Blind plugs M20 x 1 5 M1 2 x 1 5 Connection potential compensation 1 5 4 mm2 Ambient temperature range Operati...

Страница 5: ...ly under the stated ambient conditions Unfavourable ambient conditions can lead to damage of the device and thus present a potential danger for the user Regarding the assembly and installation please observe the respectively applicable installations regulations Unfavourable ambient conditions include Humidityof air too high 75 rel condensing Moisture and dust payattention to the degree of protecti...

Страница 6: ...evice then poses a potential threat to the user s life and can cause the ignition of an explosive atmosphere CE symbol We hereby declare this product is in compliance with the Essential Health and Safety Requirements of ATEX Directive 201 4 34 EU EMC Directive 201 4 30 EU Low Voltage Directive 201 4 35 EU and RoHS Directive 201 1 65 EU The appropriate standards technical regulations und specificat...

Отзывы: