background image

3

The configuration of the dFT3-IP follows as described in the instruction sheet 

   

of the normal wFT3-IP.

 

Operating position 

The telephone may be mounted on a wall or used as a desk telephone.

Service

The telephone contains no serviceable parts.

Care and maintenance

The  telephone  is  maintenance-free.  Still,  if  the  operating  area  is  highly  contaminated  by

dust, fat, oil etc., the device should be cleaned from time to time.
The device may only be cleaned using a damp cloth in order to avoid electrostatic charging.

Never use sharp objects for cleaning.
During maintenance, check accessible seals for function, e.g. regarding possible damage

or positioning. If the seals are damaged, operating the telephone is not allowed. Damaged

seals must be replaced.

Disposal

The complete device should be disposed of as electronic waste. When the device is disas-

sembled, plastics, metals and electronics components are to be disposed of separately. In

every  single  case  the  national  requirements  and  regulations  for  waste  disposal  must  be

observed.

Upon connecting the cable, please make sure the exposed conductors are placed in the

plug connector and are securely fastened.
The outer terminal of the electrostatic potential compensation (1 7) must be connected to

the potential compensation at the place of installation, in order to avoid a dangerous  electro-

static build-up in case of any electrostatic occurrence.
Marking on connection 

X1 01

Содержание dFT3-IP

Страница 1: ...Flameproof version of the weatherproof telephone wFT3 IP Operating instruction dFT3 IP 1 0 E dFT3 IP ...

Страница 2: ... dFT3 IP and guide the LAN cable through the cable gland item 4 on the lower side of the telephone and secure the cable using the cable gland The dFT3 IP delivery includes a bag with a connector socket with a cut andclamp device for connecting the LAN cable with the short 8 pin cable piece within the telephone Follow the instructions on the bag for shortening and placing the individual conductors ...

Страница 3: ...garding possible damage or positioning If the seals are damaged operating the telephone is not allowed Damaged seals must be replaced Disposal The complete device should be disposed of as electronic waste When the device is disas sembled plastics metals and electronics components are to be disposed of separately In every single case the national requirements and regulations for waste disposal must...

Страница 4: ...onnection X1 01 1 0 1 00 Mbit s LAN cable with 8 conductors AWG 22 to 24 for solid conductors or AWG 24 for multi wired conductors Dimensions Connecting cable Cable entry Cable glands M20 x 1 5 In case of factoryfitted cable glands the attached operating instructions have to be considered Blind plugs M20 x 1 5 M1 2 x 1 5 Connection potential compensation 1 5 4 mm2 Ambient temperature range Operati...

Страница 5: ...ly under the stated ambient conditions Unfavourable ambient conditions can lead to damage of the device and thus present a potential danger for the user Regarding the assembly and installation please observe the respectively applicable installations regulations Unfavourable ambient conditions include Humidityof air too high 75 rel condensing Moisture and dust payattention to the degree of protecti...

Страница 6: ...evice then poses a potential threat to the user s life and can cause the ignition of an explosive atmosphere CE symbol We hereby declare this product is in compliance with the Essential Health and Safety Requirements of ATEX Directive 201 4 34 EU EMC Directive 201 4 30 EU Low Voltage Directive 201 4 35 EU and RoHS Directive 201 1 65 EU The appropriate standards technical regulations und specificat...

Отзывы: