28
ca6552/6552sst. 2011 Audiovox Electronics Corporation. All rights reserved.
Feature Bank 3 - Output Control
1 - Extended Lock Pulse: Controls the timing of the BLUE and GREEN lock
output wires.
1 Second - Single 1 second lock pulse, single 1 second unlock pulse.
3.5 Seconds - Single 3.5 second lock pulse, single 3.5 second unlock pulse.
1 Second Lock, Double Pulse Unlock - Single 1 second lock pulse, double 1
second unlock pulse.
30 Second Lock, Double Pulse Unlock - Single 30 second lock pulse, double
1 second unlock pulse.
Double Pulse Lock, 1 Second Unlock - Double 1 second lock pulse, single 1
second unlock pulse.
2 - Factory Disarm: Controls the timing of the LT. GREEN/BLACK factory disarm
wire on the 6 pin output harness only and does not change the output of the
factory disarm wire on the 4 pin alternate output harness.
Factory Disarm - Single 1 second pulse with unlock and remote start
activation.
2nd Unlock - Same output as unlock with 2nd press of unlock.
Start Status - Single 1 second pulse with unlock and continuous ( - ) output
during the remote start cycle.
3 - Ignition Controlled Locks: Control of door locks when the ignition is cycled
ON or OFF.
OFF - Door locks not activated by ignition.
Lock and Unlock - Doors lock when ignition is turned on and unlock when
ignition is turned off.
Lock Only - Doors lock when ignition is turned on.
Unlock Only - Doors unlock when ignition is turned off.
8 - Ground While Armed / Orange Output: Controls the output of the orange
wire. This wire will either supply a ( - ) output when armed OR disarmed.