Overload Protection - The inverter will automatically shut down when the
continuous draw exceeds 700 watts.
Over Temperature Protection - When the temperature sensor inside the
ADC700 reaches 150°F, the unit will automatically shut down. Allow the unit
to cool for at least 15 minutes before restarting after a heat-related shut-
down. Unplug unit while cooling.
CAUTION: Low Battery Alarm
An alarm will sound when the voltage from the battery drops to 11.5 volts.
This is an indication that the battery needs to be recharged. The user
should stop operation of the electronic device at this time since the ADC700
will shut down automatically shortly thereafter, when the battery voltage
drops to 9.8 volts.
COMMON PROBLEMS
“Buzzing” sound in audio systems
Some inexpensive stereo systems and “boom boxes” emit a buzzing sound
from their speakers when operated from the ADC700 power inverter. This
occurs because the power supply in the electronic device does not ade-
quately filter the modified sine wave produced by the ADC700. The only
solution to this problem is to use a sound system that incorporates a higher
quality power supply.