background image

 

Hardware Installation Manual 

AudioCodes Mediant™ Family of Session Border Controllers (SBC) 

Mediant 9000 SBC 

 

Version 7.0 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

Содержание Mediant 9000

Страница 1: ...Hardware Installation Manual AudioCodes Mediant Family of Session Border Controllers SBC Mediant 9000 SBC Version 7 0...

Страница 2: ......

Страница 3: ...21 4 1 Grounding 21 4 2 Connecting to Power 22 4 2 1 Connecting to AC Power Source 22 4 2 2 Connecting to DC Power Source 24 4 3 Connecting Display and Keyboard 28 4 4 Connecting the Device to the IP...

Страница 4: ...2 Viewing Available Snapshots 46 A 3 Changing the Default Snapshot 46 A 4 Deleting a Snapshot 46 A 5 Manual Recovery 46 A 5 1 Returning to the Default Snapshot 47 A 5 2 Fixing the Current Installation...

Страница 5: ...Block Screws 26 Figure 4 7 Attaching Ground Wire 27 Figure 4 8 Attaching Power Wires 27 Figure 4 9 Replacing Safety Cover 27 Figure 4 10 Management String Name per Physical Ethernet Port 28 Figure 4 1...

Страница 6: ...ediant 9000 SBC Specifications 9 Table 2 1 Physical Dimensions 11 Table 2 2 Front Panel 11 Table 2 3 Front Panel LEDs 12 Table 2 4 Rear Panel 13 Table 2 5 Rear Panel LEDs 14 Table 4 1 AC Power Supply...

Страница 7: ...eserved This document is subject to change without notice Date Published August 16 2016 Trademarks AudioCodes AC HD VoIP HD VoIP Sounds Better IPmedia Mediant MediaPack What s Inside Matters OSN Smart...

Страница 8: ...1654 Initial document release for Version 7 0 41656 Management names of Ethernet ports added 41659 AC power cable warning Japanese Documentation Feedback AudioCodes continually strives to produce high...

Страница 9: ...r grade Mediant 9000 SBC 1 1 Specifications The table below shows the Mediant 9000 SBC specifications Table 1 1 Mediant 9000 SBC Specifications Resource Specification Chassis Type 1RU system CPU 2 x 1...

Страница 10: ...Mediant 9000 SBC Hardware Installation Manual 10 Document LTRT 41659 This page is intentionally left blank...

Страница 11: ...anel The Mediant 9000 features an 8 SFF Small Form Factor cage for standard internal storage hard drives The device s front panel is shown in the figures below and described in the subsequent table Fi...

Страница 12: ...utton LED Solid green System is On Flashing green Waiting for server power sequence Solid amber System is in standby but power is still applied Off Power cord is not attached power supply failure has...

Страница 13: ...the subsequent table Figure 2 3 Rear Panel Table 2 4 Rear Panel Item Description 1 12 GbE ports 2 Video connector 3 Serial connector 4 HP iLO port see http www8 hp com us en products servers ilo 5 USB...

Страница 14: ...Solid green Link exists Off No link exists 3 UID button LED Solid blue Identification is activated Flashing blue System is being managed remotely Off Identification is deactivated 4 Power Supply 2 LE...

Страница 15: ...nal injury or damage to the equipment at least two people are required to lift the server during installation or removal Note When installing the rack rails be sure they are oriented Front Left and Fr...

Страница 16: ...integrated shipping in a rack before proceeding 3 3 Rack Identification Legend Round hole racks Square hole racks Threaded hole racks No tools required No tools required 3 4 Installing the Rail Kit in...

Страница 17: ...Hardware Installation Manual 3 Deploying the Device Version 7 0 17 Mediant 9000 SBC...

Страница 18: ...inner slides into the slide mounting bracket assemblies Warning To reduce the risk of personal injury or damage to the equipment at least two people are required to lift the server during installatio...

Страница 19: ...ware Installation Manual 3 Deploying the Device Version 7 0 19 Mediant 9000 SBC 3 5 Removing the Rail When removing the rail from the rack always remove the front of the rail first 3 6 Securing the Ca...

Страница 20: ...for detailed information The installation is complete 3 8 Preparing the Product for Integrated Shipping in a Rack Note You must provide screws to secure the slide mounting bracket assemblies in a thr...

Страница 21: ...posed OSP cabling The addition of primary protectors is not sufficient protection to connect these interfaces metallically to OSP wiring 4 1 Grounding The device is intended for use in both common bon...

Страница 22: ...g The device must be connected by service personnel to a socket outlet with a protective earthing connection 4 2 1 Connecting to AC Power Source The AC power supply specifications are listed in the ta...

Страница 23: ...t is intended for installation where the NEC National Electrical Code applies The safety ground of the AC power cord must terminate the chassis to the interior equipment grounding system To connect th...

Страница 24: ...ification Value Input requirements Rated input voltage 36 V DC to 72 V DC 48 V DC nominal input Rated input current 23 A at 36 V DC input 17 A at 48 V DC input nominal input 12 A at 72 V DC input Rate...

Страница 25: ...f the earthing electrode conductor Caution To reduce the risk of electric shock or energy hazards This equipment must be installed by trained service personnel as defined by the NEC and IEC 60950 1 Se...

Страница 26: ...ply uses two power ring tongues and one ground ring tongue they are not interchangeable The ring tongues must be UL approved and accommodate 12 gauge wires Figure 4 4 Wire Crimped on Ring Tongue 5 Rem...

Страница 27: ...n the screws to 1 47 N m 13 lb in of torque Figure 4 8 Attaching Power Wires 9 Replace the safety cover Figure 4 9 Replacing Safety Cover 10 Insert the power supply module into the chassis power suppl...

Страница 28: ...etwork The device s management interface uses special string names to represent the Ethernet ports as shown in the figure below Figure 4 10 Management String Name per Physical Ethernet Port To connect...

Страница 29: ...Driver Info 1 GE_1 f4 ce 46 a5 3f 98 UP 1 igb rx zc 2 GE_2 f4 ce 46 a5 3f 99 DOWN 1 igb rx zc 3 GE_3 f4 ce 46 a5 3f 9a DOWN 1 igb rx zc 4 GE_4 f4 ce 46 a5 3f 9b DOWN 1 igb rx zc 5 GE_5 f4 ce 46 a5 4f...

Страница 30: ...Mediant 9000 SBC Hardware Installation Manual 30 Document LTRT 41659 This page is intentionally left blank...

Страница 31: ...ediant 9000 s Web based management tool hereafter referred to as Web interface To reconfigure the IP address using CLI 1 Use the VGA monitor and keyboard to connect to the CLI management interface 2 A...

Страница 32: ...r example VLAN ID 10 type the following commands to configure it otherwise skip to step 10 config voip interface network dev 0 network dev 0 vlan id 10 network dev 0 tagging tagged network dev 0 exit...

Страница 33: ...ation page Status Diagnostics tab System Status menu Device Information b The serial number is displayed in the Serial Number field 2 Send the serial number to your AudioCodes representative when requ...

Страница 34: ...y with your requirements a In the Current Key field select the entire text string and copy it to any standard text file e g Notepad b Save the text file with any file name and file extension e g key t...

Страница 35: ...HA system Reconfigure a temporary IP address for each as described in Section 4 2 Follow the instructions described under the section High Availability System in the User s Manual document to set netw...

Страница 36: ...Mediant 9000 SBC Hardware Installation Manual 36 Document LTRT 41659 This page is intentionally left blank...

Страница 37: ...ce is properly grounded 6 1 2 Preventing Electrostatic Discharge Damage Electrostatic discharge ESD due to improper handling of the device s modules and components can cause irreversible damage to the...

Страница 38: ...uce the risk of personal injury from hot surfaces allow the power supply or power supply blank to cool before touching it To replace the component reverse the removal procedure 6 2 2 Replacing 48V DC...

Страница 39: ...urce is off or the PDU breaker is in the off position and then disconnect the power cord from the 48V DC power source or PDU 2 Remove the power cord from the cable management arm if installed 3 Remove...

Страница 40: ...al block Note The minimum nominal thread diameter of a pillar or stud type terminal must be 3 5 mm 0 138 in the diameter of a screw type terminal must be 4 0 mm 0 157 in 7 Remove the power supply from...

Страница 41: ...the ring tongues to the power and ground cables coming from the 48V source Note The power supply uses two power ring tongues and one ground ring tongue They are not interchangeable 2 Remove the safety...

Страница 42: ...Installation Manual 42 Document LTRT 41659 4 Attach the ground earthed wire to the ground screw and washer and tighten to 1 47 N m 13 lb in of torque The ground wire must be connected before the posit...

Страница 43: ...Maintenance Version 7 0 43 Mediant 9000 SBC 5 Attach the power ring tongues to the terminal block following the polarity label below the terminal block and then tighten the screws to 1 47 N m 13 lb i...

Страница 44: ...ble management arm contact an HP authorized reseller 9 Make sure the 48V DC power source is off or the PDU breaker is in the off position and then connect the power cord to the 48V DC power source or...

Страница 45: ...first factory snapshot is automatically taken when initial installation is performed Additional snapshots up to 10 may be taken The Mediant 9000 SBC can be returned to a snapshot as described below To...

Страница 46: ...on A 6 and or Manual Recovery see Section A 5 The last user created snapshot is automatically set as default though it can be changed using the set default snapshot command Mediant SW startup n recove...

Страница 47: ...g the server start up press the Down key select Rescue option and press Enter Figure A 2 Main GRUB Menu 3 In the Rescue Options menu select Return to default snapshot and press Enter Figure A 3 Rescue...

Страница 48: ...GRUB menu select Browse available system snapshots and press Enter you re prompted to select a snapshot Figure A 5 Selecting a Snapshot 2 Select a snapshot and press Enter the system returns to the s...

Страница 49: ...tic Recovery The Mediant 9000 SBC activates Automatic Recovery when it encounters a severe software malfunction that prevents it from successfully booting for three subsequent attempts Automatic Recov...

Страница 50: ...International Headquarters Contact us www audiocodes com info Website www audiocodes com Document LTRT 41659...

Отзывы: