If the trigger is active when the last Zone is turned off, the PX-700
will not execute the Last Zone Off macro.
➤
If no Zones are on in the PX-700 Installation when the Trigger In
voltage is removed, the PX-700 executes the Last Zone Off macro.
Trigger Out
The PX-700 supplies the Trigger Out with approximately 12 VDC and,
in its default state, is active whenever any Zone in the Installation comes
on. The Trigger Out remains active until the last Zone in the Installation
is turned off. The Trigger Out state for First Zone On and Last Zone Off
events can be changed on the Events Tab in Installation Manager.
The Trigger Out and Switched Outlet will always be in the same state
relative to each other.
In multiple PX-700 Installations, the Trigger Out is active on
System 1 only.
Page Trigger
Use the Page (PDM) Trigger with the Audioaccess Page/Doorbell Module
or other paging system. When this jack is shorted, all Zones programmed
to receive paging and doorbell signals switch to the Page In until the jack is
un-shorted.
IR In and Out Jacks
The IR In jack allows hook up of an IR repeater to control Zone 6 of the
PX-700. Use this when installing the PX-700 in a closed cabinet. This auto-
matically disables the IR receiver on the front panel. Normally, the PX-700
controls the basic functions of the audio sources unless the Installation
requires control of more than the basic functions or access to other equip-
ment such as lighting and drapes, etc. If you are using an IR repeater to
control the Primary Output of Zone 6, connect the output to the PX-700
via this jack using a mono
1
⁄
8
" mini phone plug (signal and ground only).
This output merely passes the signal that comes into the IR In jack – do not
confuse it with the Source IR Output jacks. Plug IR emitters to control
equipment (other than sources controlled by the PX-700) into this mono
1
⁄
8
" mini phone jack.
In Multiple PX-700 Installations, the IR In jack is active only on System 1
.
PHYSICAL INSTALLATION