System Switches
For a single PX-700 Installation, the System Code should be set to “1”
(switch 5 up). In a multi PX-700 system, the System Code on the keypads
must be set to the System Code of the corresponding PX-700. The System
Code switches have these values: switch 5=1, switch 6=2, and switch 7=4.
Add these values together to get totals equal to the System numbers.
Consult the Wiring Instructions for specific information on each Project.
Room Switches
Switches 4 and 8 set the Room Code for the Primary and Expansion Rooms
in a Zone. Their values are: switch 4=1, switch 8=2. Add these values
together to get totals equal to the Room number.
The Primary Room is addressed as Room 0. Set DIP switches 4 and 8 down
to address the PX-700 Primary Room of the Zone. For the first Expansion
Room added to a Zone, the Room Code should be set to 1 (switch 4 up).
For the second added Room in the same Zone, set the code to 2 (switch 8
up). For the third Room added to the same Zone, set the code to 3 (switch-
es 4 and 8 up). Consult the Wiring Instructions for specific information on
each Project.
Zone, Room and System address settings are the same for the DIP switches
on the PX-603 Room Expander (see the PX-603 Installation Manual for
additional installation instructions).
NOTE
: PX-603 Rooms that are controlled by KPS keypads must have both
the PX-603 rear panel Room Configuration DIP switches and KPS keypad
DIP switches set in the manner described above.
PHYSICAL INSTALLATION