36
CU Link connection:
Up to 3 CUs can be cascaded (cascade CUs using the CU LINK
A/B terminals as shown below). Set one of the CUs as the primary
unit.
Since up to 100 DUs/INTs can be connected to each CU, if you
use 3 CUs, up to 300 DUs/INTs can be connected in total.
Follow the procedure below to cascade CUs.
①
Connect the CU LINK A terminal on the 1st extension CU to
the CU LINK B terminal on the primary CU.
②
When cascading 2 extension CUs, connect the CU LINK A
terminal on the 2nd extension CU to the CU LINK B terminal on
the 1st extension CU.
up to 100 units
up to 100 units
(INTs cannot be connected)
up to 100 units
(INTs cannot be connected)
Primary CU
1st extension
CU
Terminal A is
not used.
①
②
2nd extension
CU
Primary/Extension (CU Link Mode ):
Primary
CU
1st extension CU
2nd extension CU
2-CU Link [Primary] [Extension Last Unit]
-
3-CU Link [Primary] [Extension Pass Through] [Extension Last Unit]
• You can either daisy-chain (
➤
page 27) or ring (
➤
27) DUs/INTs to each CU.
NOTICE
• When using only one CU without a CU Link connection,
be sure to set [CU Link Setting] to [Primary]. If [CU
Link Setting] is set to [Extension], we do not assume
responsibility for any unexpected consequences that may
occur.
• Up to 6 INTs can be connected to the primary CU. They
cannot be connected to extension CUs.
3
Attach the bottom cover to the DU/INT.
After connecting the Ethernet cables to the DUs/INTs, attach the
bottom cover to each DU/INT.
• The Ethernet cable is fixed securely between the DU/INT and
the bottom cover. This helps reduce the load that the DU/INT
places on the Ethernet cables.
• To lead the cable out to the rear side, use the through hole
①
.
To lead the cable out to the bottom side, use the through holes
②
.
②
①
Bottom cover
4
Attach the optional bottom weight to the DUs/INTs.
• When using DUs/INTs that are not secured to desktops
or tabletops, it is recommended to use the optional
bottom weight (330g) for secure placement.
• To purchase the optional accessories, contact our sales
team.