background image

20      Audio Authority AVAtrix User Manual

Audio Authority AVAtrix User Manual      21

Operation

The AVAtrix allows you to select the source being played at each Cat 5 wallplate/receiver zone from the head 
end, and if the zone location is equipped with an infrared receiver, the source can be selected using an infra-
red remote control at the zone. Two operation screens are available: Residential and Professional. Use Pro-
fessional mode to control the zones from the head end. Use Residential mode if the AVAtrix is visible at the 
local zone. To switch between Residential and Professional, press the front panel MENU key, or the DISPLAY 
key on the 1105BK remote control.

In Residential mode, the normal screen displays the 
custom long name of the selected source, the six 
short names of the sources, which of these sources 
is currently selected to the Main Output (highlighted 
short name). 

The Professional screen displays the source cur-
rently assigned to each zone or group and allows 
you to choose a new source for each zone or group. 
A special group view is also available for a detailed 
overview of the sources assigned to each group.

In Professional mode, the ZONE screen displays 
the array of remote outputs. Along the bottom, it dis-
plays the six short names of the sources and which 
of these sources is currently selected to the MAIN 
(local) output (highlighted short name). To the right it 
displays the virtual MAIN, ALL and GRP modes. 

In Group View (shown) it is simple to show the cur-
rent source selected for each group. If some TVs in a group have a different source selected (e.g. Living room 
above) the AVAtrix places an asterisk by the source name displayed for that group.

Head End Operation: Key Sequence Examples 

The key sequences for several different operations using front panel controls or IR remote control are shown 
below. All examples assume the starting point is Professional Mode. To navigate using the front panel con-
trols rotate the knob to move the cursor, press the knob to change directions when appropriate (up/down vs. 
left/right).

1105BK Remote Control 

(From Professional Screen)

Changing the source on the 
local output

Double-click SOURCE; Press the desired number key or press the Left/Right SCAN 
keys. 

Changing the source on a  
ZONE (Cat 5 receiver)

Press ZONE; use the up/down/left/right keys or Alpha key/Number key to highlight the 
zone; press the SOURCE key; press the Number key for the desired source. Example: 
Zone A1, Source 4, etc.

Changing the source for a 
group of zones

Press GROUP (if necessary); use the up/down keys to highlight the desired zone 
group; touch the Number key for the desired source. Example: Group 1, Source 2, etc.

Changing the source for all 
zones

Press ALL; press the Number key for the desired source. (Press ENTER to UNDO.)

Professional mode in Group view. (Not available if no groups are 
assigned.)

Source Name

Source Number

MENU

Selecting a source in Professional Mode. Currently Source 2, which is 
Satellite Receiver #2, is selected on Cat 5 receiver (zone) A5.

Содержание High Definition Cat 5 Matrix AVX-562

Страница 1: ...Installation and Operation Model AVX 562 High Definition Cat 5 Matrix...

Страница 2: ...Audio Authority and the Double A Symbol are registered trademarks of Audio Authority Corp AVAtrix is a trademark of Audio Authority Copyright August 2008 all rights reserved HDMI the HDMI logo and Hi...

Страница 3: ...ty claim Units that fail after the warranty period has expired may be returned to the factory for repair at a nominal charge if not damaged beyond the point of repair All freight charges for out of wa...

Страница 4: ...Clean the unit only with a dry or slightly dampened soft cloth Specifications Subject to change without notice Video Parameters Signal Type Component YPbPr Video Formats 480i p 576i p 720p 1080i p In...

Страница 5: ...embly 10 Expander Address Settings 10 Cat 5 Zone Wiring 12 Remote Control Options 14 Installing Infrared Equipment 15 Entering Source Names and Custom Groups 17 Setup Menu Chart 18 PC Setup Via Flash...

Страница 6: ...5 remote outputs all offering component video with digital and analog audio The Model AVX 562 performs selection of up to six audio video input sources by infrared control RS 232 signals or by manual...

Страница 7: ...rations RGB Projector Component Video Display S Video or Composite Video Display 1362 Y Pb Pr Source PC Composite Source 1365 VGA YPbPr YPbPr YPbPr AVAtrix YPbPr YPbPr 1365 RGBHV 1361 S Video YPbPr Ca...

Страница 8: ...o Wallplates Double click for main output control in Pro Mode LOCK key used in conjunction with VIEW LOCK IR LOCK and UNLOCK keys ENTER key used to make menu selections DISPLAY key used to switch betw...

Страница 9: ...r supply LOCAL DIGITAL AUDIO OUTPUTS All digital audio inputs are available at the coaxial and optical outputs LOCAL COMPONENT VIDEO OUTPUT Component video input signals are available on YPbPr jacks L...

Страница 10: ...tool to assure that the plug is completely seated e Turn the next product to be stacked upside down e g Model 1172 or 1176 thread the bus cable through its bus access openings and engage its four thr...

Страница 11: ...ED STUDS MODEL AVX 562 1172 or 1176 AVAtrix opening screen shows expanders recognized BUS ACCESS COVER BUS ACCESS OPENING The bus cable is fragile Do not crimp or tug on the cable as you install the e...

Страница 12: ...analog audio d Connect a video display and audio system to the Local Main Output jacks Use optical and or coaxial digital audio outputs The AVAtrix does not convert digital audio to analog audio so co...

Страница 13: ...eceiver To IR distribution system Address A 18V Power Supply Basic AVAtrix Wiring d Carefully plug the pairs of cables A and B into the correct A and B AVAtrix output jacks e Connect cables to each wa...

Страница 14: ...ount each wallplate Remote Control Options Four different remote control methods may be used with the AVAtrix Native IR remote Model 1105BK Model 1105 IR codes are identical but appearance is differen...

Страница 15: ...ed from a zone to the AVAtrix can immediately select the source to be played on that wallplate receiver output Use the IR routing connections or the main IR output from the AVAtrix see 3 below c IR co...

Страница 16: ...k Emitter Pinout A passive emitter usually has a two conductor plug Tip Signal Ring Ground Sleeve 12 Volts Tip Signal Sleeve Ground Warning Connect receivers directly to wallplate receiver 12V 3 wire...

Страница 17: ...re numbered 1 6 on each output level the first level being the AVX 562 outputs The AVX 562 outputs are always addressed A and the next level Model 1176 should be B and so on An individual zone output...

Страница 18: ...g System Choose from available operating system firmware files on the flash memory card to install a firmware upgrade Contact Installer Enter contact information Up to four lines 42 characters per lin...

Страница 19: ...stom Group Names These names are the labels shown on the AVAtrix panel display repre senting each of the six available output zone groups groups of wallplate receiver locations Short group Names may h...

Страница 20: ...GRP modes In Group View shown it is simple to show the cur rent source selected for each group If some TVs in a group have a different source selected e g Living room above the AVAtrix places an aste...

Страница 21: ...rofessional Screen Changing the source on the local MAIN output Touch soft key until MAIN is highlighted touch the desired source input selection key or turn the knob Changing the source on a ZONE Cat...

Страница 22: ...tions Damaged Cat 5 port on AVAtrix Try Cat 5 cables on a different port Damaged Cat 5 receiver swap with known good receiver 1176 or 1172 Expanders not recognized Improperly seated internal bus cable...

Страница 23: ...ul for troubleshooting IR response issues in an AVAtrix system Waiting for I R data from wallplate appears on the entry screen of this diagnostic Watch this screen to indicate IR interference from a P...

Страница 24: ...232 Serial Protocols Model AVX 562 and 1176 expanders can be controlled via RS 232 from a PC or dedicated controller Two dif ferent RS 232 serial protocols are available the Abbreviated Command Set is...

Страница 25: ...ll the zones send the following command X4 All Cat 5 zones output source 4 Example 4 To change the source to an entire zone group enter Z followed by the group number followed by the desired source in...

Страница 26: ...y A special command that requests the current status of one or more connections or settings but does not change any operation within the AVAtrix A query must always contain the question mark character...

Страница 27: ...d ends with a right bracket is an invalid command and the AVAtrix responds with the string ERROR Response to C X RA O1 Im RA O2 Im RA O3 Im RA O4 Im RA O5 Im RA O6 Im RB O1 Im RB O2 Im RB O3 Im RB O4...

Страница 28: ...2048 Mercer Road Lexington Kentucky 40511 1071 Phone 859 233 4599 Fax 859 233 4510 Customer Toll Free USA Canada 800 322 8346 Website www audioauthority com v 1 0 752 564 10 08...